Introduction
Thank you for purchasing your REED R5100 Non-Contact AC Voltage
Detector. Please read the following instructions carefully before using your
instrument. By following the steps outlined in this manual your detector
will provide years of reliable service.
Product Quality
This product has been manufactured in an ISO9001 facility and has been
calibrated during the manufacturing process to meet stated product
specications.
www.GlobalTestSupply.com
Safety
• Never attempt to repair or modify your instrument. Dismantling your
product, other than for the purpose of replacing batteries, may cause
damage that will not be covered under the manufacturer's warranty.
Servicing should only be provided by an authorized service center.
• Do not use if the meter appears damaged or isn't operating properly
• Do not apply more than the specied voltage
• Use caution with voltage above 30V AC
• Before each use, verify operation by testing a known working circuit
that is within the rating of this unit
• Do not rely on this tester with shielded wire
• Operation may be affected by differences in socket design and type
Features
• Suitable for outlets or against insulated wire
• Built-in ashlight
• Double insulated housing for increased safety
• Audible (buzzer) and visual (LED) indicators when voltage present
• For use on 50/60Hz circuits
• Pocket clip
• Auto shut off
• CE and UL approved
• CAT. III 1000V, CAT. IV 600V safety ratings
www.GlobalTestSupply.com
Specifications
Voltage Range: 50 to 1000V AC
Frequency Range: 50 to 60Hz
Built-in Flashlight: Yes
Auto Power Off: Yes (after 3 minutes)
Power Supply: 2 x AAA batteries
Overvoltage Category: CAT. III 1000V, CAT. IV 600V
Product Certications: CE, UL
Operating Temperature: 32 to 104°F (0 to 40°C)
Operating Humidity: 0 to 85%
Storage Temperature: 14 to 122°F (-10 to 50°C)
Dimensions: 6.3 x 1 x 1" (159 x 25 x 25mm)
Weight: 1.5oz (42g)
Instrument Description
2
1. Probe Tip
2. Voltage Detector Power Button
3. Battery Compartment
4. Flashlight Power Button
5. Flashlight
www.GlobalTestSupply.com
3
5
4
Operating Instructions
1. Press the power button to turn the meter on.
2. The meter will beep and the probe tip will begin to ash indicating it
has been turned on and is functioning properly.
3. To turn the meter off, press and hold the power button until you hear
a beep and the tip stops ashing.
AC Voltage Measurement
1. Place the probe tip near an AC voltage location.
2. The tip will produce a steady glow and a continuous beep indicating
the presence of AC Voltage.
IMPORTANT NOTE: Receptacles in recessed sockets or differences in
socket may result in false readings.
Auto Power Off
1. After 3 minutes of inactivity the meter will automatically shut off
2. The meter will beep and stop ashing indicating it has turned off.
Flashlight
Press the ashlight button to turn the ashlight on or off.
Battery Replacement
When the battery gets low, the meter will stop ashing, even when turned
on. You will need to replace the batteries.
1. Using a athead screwdriver, slide open the battery compartment
and remove the batteries.
2. Place new batteries in the meter, and re-secure the battery
compartment cover.
www.GlobalTestSupply.com
Product Care
To keep your instrument in good working order we recommend the following:
• Store your product in a clean, dry place.
• Change the battery as needed.
• If your instrument isn't being used for a period of one month or longer
please remove the battery.
• Clean your product and accessories with biodegradable cleaner. Do not
spray the cleaner directly on the instrument. Use on external parts only.
Product Warranty
REED Instruments guarantees this instrument to be free of defects
inmaterial or workmanship for a period of one (1) year from date of
shipment. During the warranty period, REED Instruments will repair or
replace, at no charge, products or parts of a product that proves to be
defective because of improper material or workmanship, under normal
use and maintenance. REED Instruments total liability is limited to repair
or replacement of the product. REED Instruments shall not be liable for
damages to goods, property, or persons due to improper use or through
attempts to utilize the instrument under conditions which exceed the
designed capabilities. In order to begin the warranty service process,
please contact us by phone at 1-877-849-2127 or by email at
info@reedinstruments.com to discuss the claim and determine the
appropriate steps to process the warranty.
Product Disposal and Recycling
Please follow local laws and regulations when disposing or recycling your
instrument. Your product contains electronic components and must be
disposed of separately from standard waste products.
www.GlobalTestSupply.com
Product Support
If you have any questions on your product, please contact your authorized
REED distributor or REED Instruments Customer Service by phone at
1-877-849-2127 or by email at info@reedinstruments.com.
Please visit www.REEDINSTRUMENTS.com for the most
up-to-date manuals, datasheets, product guides and software.
Product specifications subject to change without notice.
All rights reserved. Any unauthorized copying or reproduction of
this manual is strictly prohibited without prior written permission
from REED Instruments.
www.GlobalTestSupply.com
TEST & MEASURE
WITH CONFIDENCE
CHECK OUT OUR LATEST PRODUCTS!
www.GlobalTestSupply.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.