Range Selection: Autoranging
True RMS: Yes
Display: 6,000 count LCD display
Display Hold: Yes
Zero Push
Button Adjustment: Yes
4
www.GlobalTestSupply.com
INSTRUMENTS
Diode Test: Yes
Backlit Display: Yes
Overrange Indicator: Yes
Continuity Check Audible signal if resistance <10Ω
Non-Contact
Voltage Detector: Yes
Autoshut off: Yes (after 15 minutes)
Power Supply: 2 AAA Batteries
Low Battery Indicator: Yes
Jaw Opening: 0.67” (17mm)
Overvoltage Category: CAT. II 600V, CAT. III 300V
Product Certications: CE, ETL, RoHS
Operating Temperature: 32 to 104°F (0 to 40°C)
Storage Temperature: 14 to 122°F (-10 to 50°C)
Dimensions: 6.9 x 2.4 x 1.3” (175 x 60 x 33.5mm)
Weight: 6oz (170g)
Optional accessories: Line Splitter (R5400)
Safety Test Lead Set (R1000)
Fused Test Lead Set (R1020)
Hard Shell Carrying Case (R9940)
Small Soft Carrying Case (CA-52A)
Overload protection: 100A
• Accuracy guarantee scale: 5~100% of measuring range, <20 digit
residual reading is allowed for 600mA open circuit.
• AC crest factor may reach 3.0 at 4,000 counts; for non-sinusoidal
waveform, the error of crest factor increases with the following formula:
a. Add 3% when the crest factor is 1~2
b. Add 5% when the crest factor is 2~2.5
c. Add 7% when the crest factor is 2.5~3
Overload protection: 600V-PTC
5
www.GlobalTestSupply.com
INSTRUMENTS
Electrical Symbols
Product Description
1. Clamp Jaws
2. Clamp Trigger (Press the
trigger to open the clamp)
3. Non Contact Voltage Indicator
4. Function Button (Change from
ACV/DCV/Hz, Resistance
Ω/Diode/Capacity, Current
ACA/DCA, NCV, Off)
5. HOLD/Backlight Button (To
keep the current measurement
on the screen / Hold button for
2 seconds for backlight to
turn on)
6. ZERO Button (Return DCA to
zero, measure the relative
value of capacity & voltage)
7. SELECT Button
8. LCD Display
9. Input Jack / COM Input Jack
6
www.GlobalTestSupply.com
INSTRUMENTS
LCD Description
7
www.GlobalTestSupply.com
INSTRUMENTS
Operating Instructions
Measuring AC/DC voltage/HZ
1. Select AC voltage and Hz or DC voltage.
2. Insert the red probe in the red jack (positive terminal) and black
probe in the black jack (COM terminal).
3. Touch the red and black probe to item under test.
4. The value will appear on the LCD.
Note: Do not exceed 600V (AC/DC)
as there is a risk of electric shock
and potential damage to the
instrument that may occur.
Measure Resistance/Diode/Circuit On/Off/Capacity
• Insert the red probe in the red jack (positive terminal) and black probe in
the black jack (COM terminal).
• Connect the probe in parallel with the tested component to measure.
• The value will appear on the LCD.
Note: When measuring the
voltage/capacity/diode range, do
not exceed DC 60 V or AC 30V to
avoid personal injury.
8
www.GlobalTestSupply.com
INSTRUMENTS
Measuring AC/DC Current
AC current
• Select your desired range for AC current (600mA~, 6,000mA~, 60A~).
Open the clamp head and attach the wire on the hook. Ensure that the
hooks are rmly closed. Value will display on the LCD.
DC current
• Press the SELECT button and enter in the DC current range (6,000mA,
60A). Press the ZERO button to bring the reading back to zero. Press
it multiple times if pressing it once doesn’t work. Open the clamp
head and attach the wire on the hook. Ensure that the hooks are rmly
closed. Value will display on the LCD.
NOTE: Pull out the testing probe
to avoid electric shock.
The clamp should be in the same
direction as the measured object
in process of zeroing obtain
accurate reading because of
the product’s high sensitivity.
9
www.GlobalTestSupply.com
INSTRUMENTS
Measuring Non-Contact Field Measurement
To measure the detected AV voltage or magnetic eld close the clamp
around the object to detect the motion. The analog quantity is “EF” when
it is ≤ critical voltage and will display as “———“, different variations of
buzzing will distinguish the intensity of detected eld.
Note: When the unit is in NVC
measurement mode, pull out
the testing probe to avoid
electric shock.
Backlight
Press the HOLD button for 2 seconds to turn on the LCD backlight.
Automatically Turns Off
If the unit is left unused for 15 minutes it will automatically turn off to
save power. Press the SELECT button in shutdown mode to power it
on. The buzzer will make 5 sounds prompting the cancellation of the
auto off function. Turn it off and then restart, the auto off function will be
recovered. The buzzer will send 5 continuous alarming sounds, and then 1
long alarming sound before the product automatically shuts down. When
the auto off function is canceled, it will send 5 alarming sounds every 15
minutes.
10
www.GlobalTestSupply.com
INSTRUMENTS
Functions
When pressing any function button or turning any switch the buzzer
will make a “beep” noise. When the measuring voltage or current the
buzzer will also send a continuous “beep” intermittent sound to warm
the outrange. The functions are: AC/DC voltage >about 600V, mA AC/DC
current >620mA (or 6200mA), A AC/DC large current >62A.
Battery Replacement
1. Ensure the power switch is set
to “OFF” and pull the probe
out of input jack.
2. Remove the battery cover with
a screwdriver.
3. Install two new AAA batteries.
4. Replace the cover and screw
in the battery cover.
For service on this or any other REED product or information on other
REED products, contact REED Instruments at info@reedinstruments.com.
www.GlobalTestSupply.com