Introduction
Thank you for purchasing your REED R2310 Infrared Thermometer. Please
read the following instructions carefully before using your instrument. By
following the steps outlined in this manual your meter will provide years of
reliable service.
Product Quality
This product has been manufactured in an ISO9001 facility and has been
calibrated during the manufacturing process to meet stated product
specications. If a certicate of calibration is required please contact the
nearest authorized REED distributor or authorized Service Center. Please
note an additional fee for this service will apply.
Safety
• Never attempt to repair or modify your
instrument. Dismantling your product,
other than for the purpose of replacing
batteries, may cause damage that will
not be covered under the manufacturer’s
warranty. Servicing should only be
provided by an authorized service center.
• Use extreme caution when the laser beam
is turned on.
• Do not let the beam enter your eye, another person's eye or the eye of
an animal.
• Be careful not to point the beam off a reective surface and strike your eye.
• Do not allow the laser light beam to impinge on any gas which can explode.
www.GlobalTestSupply.com
Features
• Built-in laser pointer identies target area
• User selectable °F or °C
• 12:1 distance to spot size ratio
• Digitally adjustable emissivity
• Max, Min, Average and Differential readings
• Backlit display
• High and low alarms
• Dustproof and Drop tested
• Trigger lock for continuous monitoring
• Low battery indication and auto shut off
Included
• Carrying Case
• Battery
Specifications
Temperature Range: -31 to 1202°F (-35 to 650°C)
Accuracy: ≥32°F (0°C):±3.6°F (1.8°C) or
±1.8% rdg., whichever is greater
<32°F (0°C):±3.6°F+0.1°F/°F
Alarm Indicators: LED (High: Red, Low: Blue)
Max/Min: Yes
Average and Differential: Yes
F/C Switchable: Yes
Trigger Lock: Yes
Tripod Mountable: Yes
Drop Tested: Yes, 9.8' (3M)
Laser Type: Class II
Low Battery Indicator: Yes
Power Supply: 9V battery
Battery Life: Approx. 10 hours
(with continuous use, backlight on)
Product Certications: CE, RoHS, IP65, Drop Tested
Operating Temperature: 32 to 122°F (0 to 50°C)
Storage Temperature: -4 to 140°F (-20 to 60°C)
Operating Humidity Range: 10 to 90%
Maximum Operating Altitude: 6561' (2000m)
Maximum Storage Altitude: 39370' (12000m)
Dimensions: 7.4 x 4.7 x 2.2" (189 x 118 x 55mm)
Weight: 10.3oz (292g)
www.GlobalTestSupply.com
Instrument Description
1
2
3
12
10
11
1
2
3
1. Laser Pointer Beam
2. IR Sensor
3. Trigger
4. High/Low Alarm Indicators
5. LCD Display
6. Mode Button/Down Arrow
4
5
6
7
8
7. Set Button
8. High/Low Alarm Button/
Up Arrow
9. Handle Grip
10. Battery Cover
11. Battery Compartment Screw
12. Tripod Mount
9
www.GlobalTestSupply.com
Display Description
Temperature Measurement Trigger Lock
Laser ON
High and Low Limit Alarm
Low Battery
Temperature Measurement Active
Measurement Data Hold
Unit of Measurement
Temperature Measurement Value
Mode
Emissivity
Temperature Measurement Value from Selected Mode
www.GlobalTestSupply.com
Distance & Spot Size
www.GlobalTestSupply.com
Operating Instructions
Power ON and OFF
1. Gently pull the trigger to turn the thermometer on. The LCD
display and white backlight will turn on.
2. The thermometer will automatically shut off after 8 seconds
of inactivity.
Manual Measurement
1. Pull and hold the trigger after aiming at the target. The icon
will ash, indicating that the target temperature is being measured.
2. When the trigger is released, the icon will disappear and the
Continuous Temperature Measurement (Trigger Lock)
1. Once the trigger lock function is enabled (see page 12), the icon
2. Pull the trigger again to stop measuring and the and icons
icon will appear indicating that measurement has stopped
and the last measured temperature will remain on-screen until
another measurement is taken or the unit turns off.
will appear on the display and the icon will ash when the
trigger is pressed. The thermometer will continuously measure
temperature and the backlight will auto shut off after 2 minutes.
will disappear and the icon will appear. The thermometer will
keep the last measured value until the unit turns off.
www.GlobalTestSupply.com
continued...
Maximum, Minimum, Average and Differential Functions
Press the MODE button to toggle between MAX/MIN/AVG/DIF modes.
The temperature value of corresponding modes are shown in the
secondary display area.
Setting the High Temperature Alarm
Press the SET button once to enter the high alarm limit setup. Use the UP
and DOWN buttons to set temperature value. Press the UP and DOWN
buttons to add or subtract 1. Hold the UP or DOWN buttons to add or
subtract 10 temperature values. The instrument will exit the setup after 5
seconds of inactivity.
www.GlobalTestSupply.com
continued...
Setting the Low Temperature Alarm
Press the SET button twice to enter the low alarm limit setup. Use the UP
and DOWN buttons to set values. Press the UP and DOWN buttons to
add or subtract 1 temperature value. Hold the UP or DOWN buttons to
add or subtract 10 temperature values. The instrument will exit the setup
after 5 seconds of inactivity.
Adjusting Emissivity
The instrument's emissivity can be adjusted from 0.01 to 1.0. Press the
SET button three times to enter the emissivity setup. Use the UP and
DOWN buttons to set the values. Press the UP and DOWN buttons to
add or subtract 0.01 unit and/or hold the UP and DOWN buttons to add
or subtract 0.1. The thermometer will exit the setup after 5 seconds of
inactivity.
www.GlobalTestSupply.com
continued...
Switching the Unit of Measure (°F/°C)
Press the SET button four times to enter unit of measure setup. Use the UP
and DOWN buttons to switch between °F and °C units. The thermometer
will exit the setup after 5 seconds of inactivity.
Turning Laser ON/OFF
To turn the laser on or off, press the SET button ve times to enter laser
setup. Use the UP and DOWN buttons to turn the laser on or off. The
thermometer will exit the setup after 5 seconds of inactivity.
Trigger Lock Setup
To turn the lock measurement on or off, press the SET button six times to
enter lock measurement setup. Use the UP and DOWN buttons to feature
on or off. The thermometer will exit the setup after 5 seconds of inactivity.
www.GlobalTestSupply.com
continued...
Turning High and Low Alarms ON/OFF
1
2
Press the button to enter alarm setup screen. Press the
button again to toggle through the alarm functions.
1. High/Low alarms on.
2. High alarm on.
3. Low alarm on.
4. No alarm set.
3
4
www.GlobalTestSupply.com
Battery Replacement
1. The battery should be replaced when is displayed.
2. Remove the screw with a at screwdriver and open the battery cover.
3. Replace the 9V battery.
4. Place the battery cover back and tighten the screw.
• Calibration and control of heater and oven temperatures
• Monitoring materials in processes involving heating and/or cooling
• Quality control monitoring
• Research and development applications
• Automotive diagnostics
• Conduct HVAC energy audits
www.GlobalTestSupply.com
Appendix: Emissivity Chart
Emissivity is a term used to describe the energy-emitting characteristics of
materials. Most (90% of typical applications) organic materials and painted
or oxidized surfaces have an emissivity of 0.95.
Inaccurate readings will result from measuring shiny or polished metal
surfaces. To compensate, cover the surface to be measured with masking
tape or at black paint. Allow time for the tape to reach the same temperature as the material underneath it. Measure the temperature of the tape or
painted surface.
To keep your instrument in good working order we recommend the following:
• Store your product in a clean, dry place.
• Change the battery as needed.
• If your instrument isn’t being used for a period of one month or longer
please remove the battery.
• Clean your product and accessories with biodegradable cleaner. Do not
spray the cleaner directly on the instrument. Use on external parts only.
Product Warranty
REED Instruments guarantees this instrument to be free of defects in
material or workmanship for a period of one (1) year from date of shipment.
During the warranty period, REED Instruments will repair or replace, at no
charge, products or parts of a product that proves to be defective because
of improper material or workmanship, under normal use and maintenance.
REED Instruments total liability is limited to repair or replacement of the
product. REED Instruments shall not be liable for damages to goods,
property, or persons due to improper use or through attempts to utilize the
instrument under conditions which exceed the designed capabilities. In
order to begin the warranty service process, please contact us by phone at
1-877-849-2127 or by email at info@reedinstruments.com to discuss the
claim and determine the appropriate steps to process the warranty.
Product Disposal and Recycling
Please follow local laws and regulations when disposing or recycling your
instrument. Your product contains electronic components and must be
disposed of separately from standard waste products.
www.GlobalTestSupply.com
Product Support
If you have any questions on your product, please contact your authorized
REED distributor or REED Instruments Customer Service by phone at
1-877-849-2127 or by email at info@reedinstruments.com.
Please visit www.REEDINSTRUMENTS.com for the most
up-to-date manuals, datasheets, product guides and software.
Product specifications subject to change without notice.
All rights reserved. Any unauthorized copying or reproduction of
this manual is strictly prohibited without prior written permission
from REED Instruments.
www.GlobalTestSupply.com
TEST & MEASURE
WITH CONFIDENCE
www.GlobalTestSupply.com
TEMPERATURE
& HUMIDITY
SOUND
MOISTURE
www.GlobalTestSupply.com
AIR VELOCITY
ELECTRICAL
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.