REED Instruments R2310-NIST, R2310 User manual

Infrared Thermometer
R2310
Instruction Manual
www.GlobalTestSupply.com
Table of Contents
Specications ............................................................................................. 4-5
Operating Instructions .............................................................................. 9-13
Power ON and OFF .................................................................................. 9
Manual Measurement ............................................................................... 9
Continuous Temperature Measurement (Trigger Lock) ............................ 9
Maximum, Minimum, Average and Differential Functions ...................... 10
Setting the High Temperature Alarm ...................................................... 10
Setting the Low Temperature Alarm ....................................................... 11
Adjusting Emissivity ................................................................................ 11
Switching the Unit of Measure (°F/°C) .................................................... 12
Turning Laser ON/OFF............................................................................ 12
Trigger Lock Setup ................................................................................. 12
Turning High and Low Alarms ON/OFF .................................................. 13
Battery Replacement ................................................................................... 14
Applications ................................................................................................. 14
Appendix: Emissivity Chart ....................................................................15-16
Product Care ............................................................................................... 17
Product Warranty ........................................................................................ 17
Product Disposal and Recycling ................................................................. 17
Product Support .......................................................................................... 18
www.GlobalTestSupply.com
Introduction
Thank you for purchasing your REED R2310 Infrared Thermometer. Please read the following instructions carefully before using your instrument. By following the steps outlined in this manual your meter will provide years of reliable service.
Product Quality
This product has been manufactured in an ISO9001 facility and has been calibrated during the manufacturing process to meet stated product specications. If a certicate of calibration is required please contact the nearest authorized REED distributor or authorized Service Center. Please note an additional fee for this service will apply.
Safety
• Never attempt to repair or modify your instrument. Dismantling your product, other than for the purpose of replacing batteries, may cause damage that will not be covered under the manufacturer’s warranty. Servicing should only be provided by an authorized service center.
• Use extreme caution when the laser beam is turned on.
• Do not let the beam enter your eye, another person's eye or the eye of an animal.
• Be careful not to point the beam off a reective surface and strike your eye.
• Do not allow the laser light beam to impinge on any gas which can explode.
www.GlobalTestSupply.com
Features
• Built-in laser pointer identies target area
• User selectable °F or °C
• 12:1 distance to spot size ratio
• Digitally adjustable emissivity
• Max, Min, Average and Differential readings
• Backlit display
• High and low alarms
• Dustproof and Drop tested
• Trigger lock for continuous monitoring
• Low battery indication and auto shut off
Included
• Carrying Case
• Battery
Specifications
Temperature Range: -31 to 1202°F (-35 to 650°C) Accuracy: ≥32°F (0°C):±3.6°F (1.8°C) or
±1.8% rdg., whichever is greater <32°F (0°C):±3.6°F+0.1°F/°F
(1.8°C+0.1°C/°C) Resolution: 0.1°F (0.1°C) Optical Resolution (D:S): 12:1 Spectral Response: 8 to 14µm Emissivity: 0.1 to 1.0 (Adjustable) Response Time: 250ms Backlit Display: Yes Display Hold: Yes High/Low Alarms: Yes
continued...
www.GlobalTestSupply.com
Alarm Indicators: LED (High: Red, Low: Blue) Max/Min: Yes Average and Differential: Yes F/C Switchable: Yes Trigger Lock: Yes Tripod Mountable: Yes Drop Tested: Yes, 9.8' (3M) Laser Type: Class II Low Battery Indicator: Yes Power Supply: 9V battery Battery Life: Approx. 10 hours
(with continuous use, backlight on) Product Certications: CE, RoHS, IP65, Drop Tested Operating Temperature: 32 to 122°F (0 to 50°C) Storage Temperature: -4 to 140°F (-20 to 60°C) Operating Humidity Range: 10 to 90% Maximum Operating Altitude: 6561' (2000m) Maximum Storage Altitude: 39370' (12000m) Dimensions: 7.4 x 4.7 x 2.2" (189 x 118 x 55mm) Weight: 10.3oz (292g)
www.GlobalTestSupply.com
Instrument Description
1
2
3
12
10
11
1
2
3
1. Laser Pointer Beam
2. IR Sensor
3. Trigger
4. High/Low Alarm Indicators
5. LCD Display
6. Mode Button/Down Arrow
4
5
6
7
8
7. Set Button
8. High/Low Alarm Button/ Up Arrow
9. Handle Grip
10. Battery Cover
11. Battery Compartment Screw
12. Tripod Mount
9
www.GlobalTestSupply.com
Display Description
Temperature Measurement Trigger Lock
Laser ON
High and Low Limit Alarm
Low Battery
Temperature Measurement Active
Measurement Data Hold
Unit of Measurement
Temperature Measurement Value
Mode
Emissivity
Temperature Measurement Value from Selected Mode
www.GlobalTestSupply.com
Distance & Spot Size
www.GlobalTestSupply.com
Operating Instructions
Power ON and OFF
1. Gently pull the trigger to turn the thermometer on. The LCD display and white backlight will turn on.
2. The thermometer will automatically shut off after 8 seconds of inactivity.
Manual Measurement
1. Pull and hold the trigger after aiming at the target. The icon will ash, indicating that the target temperature is being measured.
2. When the trigger is released, the icon will disappear and the
Continuous Temperature Measurement (Trigger Lock)
1. Once the trigger lock function is enabled (see page 12), the icon
2. Pull the trigger again to stop measuring and the and icons
icon will appear indicating that measurement has stopped and the last measured temperature will remain on-screen until another measurement is taken or the unit turns off.
will appear on the display and the icon will ash when the trigger is pressed. The thermometer will continuously measure temperature and the backlight will auto shut off after 2 minutes.
will disappear and the icon will appear. The thermometer will keep the last measured value until the unit turns off.
www.GlobalTestSupply.com
continued...
Maximum, Minimum, Average and Differential Functions
Press the MODE button to toggle between MAX/MIN/AVG/DIF modes. The temperature value of corresponding modes are shown in the secondary display area.
Setting the High Temperature Alarm
Press the SET button once to enter the high alarm limit setup. Use the UP and DOWN buttons to set temperature value. Press the UP and DOWN buttons to add or subtract 1. Hold the UP or DOWN buttons to add or subtract 10 temperature values. The instrument will exit the setup after 5 seconds of inactivity.
www.GlobalTestSupply.com
continued...
Setting the Low Temperature Alarm
Press the SET button twice to enter the low alarm limit setup. Use the UP and DOWN buttons to set values. Press the UP and DOWN buttons to add or subtract 1 temperature value. Hold the UP or DOWN buttons to add or subtract 10 temperature values. The instrument will exit the setup after 5 seconds of inactivity.
Adjusting Emissivity
The instrument's emissivity can be adjusted from 0.01 to 1.0. Press the
SET button three times to enter the emissivity setup. Use the UP and DOWN buttons to set the values. Press the UP and DOWN buttons to
add or subtract 0.01 unit and/or hold the UP and DOWN buttons to add or subtract 0.1. The thermometer will exit the setup after 5 seconds of inactivity.
www.GlobalTestSupply.com
continued...
Switching the Unit of Measure (°F/°C)
Press the SET button four times to enter unit of measure setup. Use the UP and DOWN buttons to switch between °F and °C units. The thermometer will exit the setup after 5 seconds of inactivity.
Turning Laser ON/OFF
To turn the laser on or off, press the SET button ve times to enter laser setup. Use the UP and DOWN buttons to turn the laser on or off. The thermometer will exit the setup after 5 seconds of inactivity.
Trigger Lock Setup
To turn the lock measurement on or off, press the SET button six times to enter lock measurement setup. Use the UP and DOWN buttons to feature on or off. The thermometer will exit the setup after 5 seconds of inactivity.
www.GlobalTestSupply.com
continued...
Turning High and Low Alarms ON/OFF
1
2
Press the button to enter alarm setup screen. Press the button again to toggle through the alarm functions.
1. High/Low alarms on.
2. High alarm on.
3. Low alarm on.
4. No alarm set.
3
4
www.GlobalTestSupply.com
Battery Replacement
1. The battery should be replaced when is displayed.
2. Remove the screw with a at screwdriver and open the battery cover.
3. Replace the 9V battery.
4. Place the battery cover back and tighten the screw.
Applications
• Verify mechanical (bearings, motors) or electrical (circuit breaker boxes) equipment
• Calibration and control of heater and oven temperatures
• Monitoring materials in processes involving heating and/or cooling
• Quality control monitoring
• Research and development applications
• Automotive diagnostics
• Conduct HVAC energy audits
www.GlobalTestSupply.com
Appendix: Emissivity Chart
Emissivity is a term used to describe the energy-emitting characteristics of materials. Most (90% of typical applications) organic materials and painted or oxidized surfaces have an emissivity of 0.95. Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate, cover the surface to be measured with masking tape or at black paint. Allow time for the tape to reach the same tempera­ture as the material underneath it. Measure the temperature of the tape or painted surface.
Measured Surfaces Emissivity
Metal
Aluminum: Oxidization 0.2-0.4
A3003 Alloy: Oxidization, Rough 0.3, 0.1-0.3
Brass: Burnishing, Oxidization 0.3, 0.5
Copper: Oxidization, Electric Temrinal Board
Hastelloy: Alloy 0.3-0.8
Inconel: Oxidization, Sand-Blasting, Electro Burnishing
Iron: Oxidization, Rusting 0.5-0.9, 0.5-0.7
Iron (Casting): Oxidization, Non-Oxidization, Casting
Iron (Forging): Passivation 0.9
Lead: Rough, Oxidization 0.4, 0.2-0.6
Molybdenum: Oxidization 0.2-0.6
Nickel: Oxidization 0.2-0.5
Platinum: Black 0.9
0.4-0.8, 0.6
0.7-0.95, 0.3-0.6, 0.15
0.6-0.95, 0.2, 0.2-0.3
www.GlobalTestSupply.com
continued...
Measured Surfaces Emissivity
Steel: Cold Rolling, Steel PlateBur­nishing, Steel Plate Rubbing
0.7-0.9, 0.4-0.6, 0.1
Zinc: Oxidization 0.1
Non-Metal
Asbestos 0.95
Asphalt 0.95
Basalt 0.7
Carbon: Non-Oxidization, Graphite, Silicone Carbide
0.8-0.9, 0.7-0.8, 0.9
Ceramics 0.95
Clay 0.95
Concrete 0.95
Cloth 0.9
Glass: Convex, Smooth,
0.76-0.8, 0.92-0.94, 0.78-0.82
Lead-Boron
Plates 0.96
Stone Products 0.93
Plaster 0.8-0.95
Ice 0.98
Limestone 0.98
Paper 0.95
Plastics 0.95
Water 0.93
Soil 0.9-0.98
Wood 0.9-0.95
www.GlobalTestSupply.com
Product Care
To keep your instrument in good working order we recommend the following:
• Store your product in a clean, dry place.
• Change the battery as needed.
• If your instrument isn’t being used for a period of one month or longer please remove the battery.
• Clean your product and accessories with biodegradable cleaner. Do not spray the cleaner directly on the instrument. Use on external parts only.
Product Warranty
REED Instruments guarantees this instrument to be free of defects in material or workmanship for a period of one (1) year from date of shipment. During the warranty period, REED Instruments will repair or replace, at no charge, products or parts of a product that proves to be defective because of improper material or workmanship, under normal use and maintenance. REED Instruments total liability is limited to repair or replacement of the product. REED Instruments shall not be liable for damages to goods, property, or persons due to improper use or through attempts to utilize the instrument under conditions which exceed the designed capabilities. In order to begin the warranty service process, please contact us by phone at 1-877-849-2127 or by email at info@reedinstruments.com to discuss the claim and determine the appropriate steps to process the warranty.
Product Disposal and Recycling
Please follow local laws and regulations when disposing or recycling your instrument. Your product contains electronic components and must be disposed of separately from standard waste products.
www.GlobalTestSupply.com
Product Support
If you have any questions on your product, please contact your authorized REED distributor or REED Instruments Customer Service by phone at 1-877-849-2127 or by email at info@reedinstruments.com.
Please visit www.REEDINSTRUMENTS.com for the most
up-to-date manuals, datasheets, product guides and software.
Product specifications subject to change without notice. All rights reserved. Any unauthorized copying or reproduction of this manual is strictly prohibited without prior written permission from REED Instruments.
www.GlobalTestSupply.com
TEST & MEASURE
WITH CONFIDENCE
www.GlobalTestSupply.com
TEMPERATURE & HUMIDITY
SOUND
MOISTURE
www.GlobalTestSupply.com
AIR VELOCITY
ELECTRICAL
Loading...