Introduction
This compact light meter is capable of taking Lux and
Footcandle (Fc) measurements. The R1930 features a backlit
LCD display, data hold and min/max functions, low battery
indicator and auto shut-off.
Warning:
Before using the product, please read the operation
manual carefully.
Operation Safety
1. Check the meter before using to ensure the instrument
is not damaged.
2. Do not open the meter.
3. When the LCD displays replace battery as
soon as possible.
4. Remove the batteries if the instrument will not be used
for an extended period of time.
5. Do not use the meter in high temperature, humidity,
flammable, combustible or strong electromagnetic
environments.
6. Use a soft cloth and neutral detergent to clean the
instrument. Do not use strong agents or solvents.
Display Description
1. Maximum
2. Minimum
3. Data Hold
4. Low Battery Indicator
5. Foot Candle
6. Lux
7. Value 10 or Value 10
8. Illumination Value
Specifications
Measuring Ranges: Lux: 0 to 199999
Fc: 0 to 18580
Accuracy: 0 to 9999 Lux (0 to 929 Fc):
±(4% rdg.+ 8 dgt)
≥10000 Lux (≥1000 Fc):
±(5% rdg.+ 10 dgt)
≥100000 Lux (≥9999 Fc):
±(5% rdg.+ 10 dgt)
Resolution: Lux: 1, 10, 100
Fc: 1, 10
Sensor Type: Silicon photocell
Display: 4-digit LCD
Backlit Display: Yes
Data Hold: Yes
Minimum: Yes
Maximum: Yes
Overrange Indicator: Yes
Sampling Rate: 2 times/second
Auto Shut-Off: Yes (after 5 minutes, off)
Low Battery Indicator: Yes
Power Supply: 3 "AAA" batteries
Product Certifications: CE
Storage Temperature: 4 to 140°F (-10 to 60°C)
Operating Humidity Range: 10 to 80%
Dimensions: 6.3 x 1.9 x 1.1"
Poids: 4.2oz (118g)
Battery Installation and Replacement
1. This meter uses 3 AAA batteries. Refer to the figure
below for battery installation and replacement steps.
2. Push the battery cover open in the direction of the arrow,
lift the cover and remove the batteries.
3. Install new batteries in accordance of polarity indications.
4. Close the cover tightly after installing new batteries.
Key Functions & Setup
ON/OFF
Press once to turn on unit. Press again to power off. Disable
the product's auto power off feature by pressing and holding
HOLD and then press the ON/OFF key to enable/disable
auto power off, LCD will display "APO OFF" to
indicate status.
LUX/FC
Unit conversion button. Press this button to select Lux or
Foot Candles.
MAX/MIN
Press this button to cycle through maximum, minimum
and live measurement functions. Select maximum and the
maximum reading will be shown; select minimum and the
minimum reading will be shown.
HOLD/BL
HOLD: Press the button once to hold the measurement and
press it again to continue measuring.
BL: Hold button to turn the backlight display on and off.
www.GlobalTestSupply.com
For service or information on this or any other REED product,
contact REED Instruments at info@reedinstruments.com.