Safety
To prevent electric shock or re carefully read all safety information before operating this adaptor:
• Do not use this clamp on circuits rated higher than 600V in Installation Category II
• Use caution when clamping around uninsulated conductors or bus bars
• Do not use the clamp if it is cracked, damaged, or has a defective cable
• Check the magnetic mating surfaces of the clamp jaws; these should be free of dust, dirt, rust, and other foreign matter
• Keep your ngers off the clamp jaws
• Keep your ngers behind the safety barrier
Specifications
AC Current Range: 0-200A
AC Current Accuracy: ±2.0% ±0.5A
AC Current Output: 1mV/A
AC Current Sensitivity: 1A/mV AC
Output Impedance: <1kΩ
AC Bandwidth: 40 to 400Hz
Jaw Opening: 0.62” (16mm)
Operating Conditions: 32 to 122°F (0 to 50°C), 45 to 90% RH
Dimensions: 4.37 x 1.96 x 1.29” (111 x 50 x 33mm)
Weight: 4.55lb (129g)
www
www.GlobalTestSupply. com
reedinstruments
com
2
Pantone 534 Blue Pantone 123 Yellow
Pantone 485 Red Pantone 123 Yellow
Pantone 534 Blue
Black
Rich Black - 20/20/20/100
Blue - 100/80/30/5 Yellow - 0/27/100/0
Red - 10/100/100/5 Yellow - 0/27/100/0
Blue - 100/80/30/5
Instrument Description
1. Clamp Jaw
2. Clamp Trigger
3. Safety Barrier
4. Voltage Output Lead
www
www.GlobalTestSupply. com
reedinstruments
com
3
Pantone 534 Blue Pantone 123 Yellow
Pantone 485 Red Pantone 123 Yellow
Pantone 534 Blue
Black
Rich Black - 20/20/20/100
Blue - 100/80/30/5 Yellow - 0/27/100/0
Red - 10/100/100/5 Yellow - 0/27/100/0
Blue - 100/80/30/5
Operating Instructions
• Connect the test leads to the voltage output lead of the Clamp Adaptor and input shock of the voltage measurement device
• Turn on the voltage measurement device and set it to AVC 200mV or 400mV
• Position the Clamp Adaptor perpendicular to and centered around the conductor
• Read the measured value on the voltage measurement device