Redvision RVX18, RVX-PSU-ALM16, RVX-PSU, RVX-PSU-ALM16-W, RVX18-W User Manual

...
X-SERIES
USER MANUAL
Products Covered:
RV X-SERIES™ PTZ Positioning Camera RVX-PSU Power Supply RVX-PSU-ALM16 Power Supply with Alarm Module RVX-PSU-ALM16-W PSU with Wireless PIR module
© 2012 Redvision CCTV Limited. All rights reserved.
X-SERIESTMUSER MANUAL
1 INSTALLING THE CAMERA HEAD
1.1 CONVERT DOME TO BALL PTZ CONFIGURATION
1.2 ATTACHING CAMERA TO BRACKET
1.3 BRACKET TYPES
1.4 HOW TO CANTILEVER BALL/PTZ ARMS FORWARD
2 HOW TO CONFIGURE THE CAMERA
2.1 REMOVING THE DIP SWITCH SCREW COVER
2.1.1 CAMERA ORIENTATION FOR SETTING DIP SWITCHES
2.1.2
DEFAULT DIP SWITCH SETTINGS
2.2 SETTING THE CAMERA ADDRESS
2.3
SETTING THE CAMERA PROTOCOL
2.4 SETTING THE CAMERA BAUD RATE
2.5 SETTING THE CAMERA RS485 TERMINATION
2.6 REAL TIME CLOCK (RTC)
2.7 REPLACING THE DIP SWITCH COVER
3 POWER SUPPLY INSTALLATION
3.1 REDVISION POWER SUPPLY(RVX-PSU)
3.2 VOLTAGE
3.3 RVX-PSU INTERNAL CONNECTIONS
3.3.1 MAINS INPUT
3.3.2
CONNECTIONS TO CAMERA – 8 WAY BLOCK
3.3.3 CONNECTIONS TO CONTROL – 8 WAY BLOCK
3.3.4 RS485 DIAGNOSTIC LEDS
3.3.5 FUSE PROTECTION
4 RVX-PSU-ALM16 (PSU WITH ALARM MODULE)
4.1 VOLTAGE
4.2 RVX-PSU-ALM16 CONNECTIONS
4.2.1 MAINS INPUT
4.2.2
CONNECTIONS TO CAMERA (8 WAY BLOCK)
4.2.3 CONNECTIONS TO CONTROL (8 WAY BLOCK)
4.2.4 RS485 DIAGNOSTIC LEDS
4.2.5 FUSE PROTECTION
4.3 ALARM MODULE DIP SWITCH SETTINGS
4.3.1 PROTOCOL - ALARM MODULE
4.3.2
BAUD RATE - ALARM MODULE
4.3.3 RS485 TERMINATION - ALARM MODULE
4.4 ALARM INPUTS
4.4.1 ALARM INPUTS - GROUNDS
4.4.2
ALARM RELAY OUTPUTS (VOLT FREE)
4.5 NORMALLY OPEN/CLOSED ALARM INPUTS
4.5.1 TERMINATION SCENARIOS
5 WIRELESS ALARM CARD (WIRELESS PIR DETECTOR)
5.1 FACTORY FITTED WIRELESS CARD (RVX-PSU-ALM16-W)
5.1.1 CONFIGURING WIRELESS ALARM MODULE
5.1.2 POSITIONING OF RVX-PSU-ALM16-W
5.2 IF RETRO FITTING WIRELESS ALARM RECEIVER
Table of Contents
X-SERIESTMUSER MANUAL
6 NAVIGATING THE MENUS
6.1 MENU NAVIGATION - FLOW CHART
6.1.1 ACCESS MAIN MENU FROM 3RD PARTY CONTROLLERS
6.1.2
EXIT MENU
6.2 LOGIN
6.3
LOGIN EXPIRY
6.4 SET UP
6.4.1 ENTER DATE & TIME CLOCK
6.4.2
DAYLIGHT SAVING
6.4.3 LANGUAGE OPTIONS
6.4.4 DISPLAY
6.4.5 PASSWORDS
6.4.6 DATUM CHECK
6.4.7 CAMERA ORIENTATION
6.4.8 DATE AND TIME OF INSTALLATION
6.4.9 CLEAR SETTINGS
6.4.10 DIAGNOSTICS
7 NIGHT MODE
7.1 SELECT NIGHT MODE
7.2 NIGHT MODE SWITCHING
7.3 ON LEVEL
7.4 OFF LEVEL
7.5 AUTO SWITCH DELAY
7.6 ON TIMES
7.7 INFRA RED POWER (RVX - IR VERSION ONLY)
8 CAMERA SETTINGS
8.1 DAY MODE SETTINGS
8.2 LOW LIGHT MODE SETTINGS
8.3 IR MODE SETTINGS
8.4 VIDEO GAIN
8.5 VIDEO LIFT
8.6 IRIS KEY USAGE
8.7 DIGITAL ZOOM
8.8 INVERT CAMERA IMAGE
8.9 CROSS HAIR
9 JOYSTICK & WIPER
9.1 JOYSTICK CURVE
9.2 ZOOM RATIO
9.3 JOYSTICK SPEED
9.4 WIPER
9.4.1 INTERMITTENT WIPE
9.4.2 WIPER TIMEOUT
9.4.3
WIPE SHORTCUT PRESET
9.4.4 WASH SHORTCUT PRESET
9.5 PAN LIMITS
9.6
TILT LIMITS
9.7 SHORTCUTS
9.8 AUX RELAY FUNCTIONS
9.9 COMPATIBILITY MODE
X-SERIESTMUSER MANUAL
10 PRESETS & TOURS
10.1 FOCUS SHIFT
10.2 PRESET
10.2.1 SET A PRESET (USING CAMERA INTERNAL MENU)
10.2.2
EDIT PRESET
10.2.3 PRESET SPEED
10.3
TOURS
10.3.1 TOUR 1 TO 8
10.4 RESTORE (PRESETS AND TOURS)
10.4.1 RESTORE TO NUMBER – EITHER TOUR OR PRESET NUMBER
10.4.2 TIMED RESTORE WEEKDAY
10.4.3 TIMED RESTORE WEEKEND
10.4.4 RESTORE MODE (PRESETS & TOURS)
10.4.5 RESTORE DELAY (PRESETS & TOURS)
11 PRIVACY ZONES
11.1 SET/CLEAR MASK
11.2 ZOOM THRESHOLD
11.3 EDIT MASK
12 ALARM HANDLING IN MENU SOFTWARE
12.1 ENABLE /DISABLE ALARMS
12.2 ALARM OVER-RIDE
12.3 ALARM CYCLE TIME
12.4 EDIT ALARMS
12.4.1 ACTIVE TIME WEEKDAYS
12.4.2
ACTIVE TIME WEEKENDS
12.4.3 ACTION WHEN ACTIVE
12.4.4 ACTION NUMBER
12.4.5 ACTION WHEN MASKED
12.4.6 TITLE
12.4.7 NEW ALARM DWELL
12.4.8 SHOW ALARM INFO
12.4.9 CLEAR COUNTERS
13 CONTACT TECHNICAL SUPPORT
14 TECHNICAL SPECIFICATION
15 WARRANTY INFORMATION
X-SERIESTMUSER MANUAL
NOTES
X-SERIESTMUSER MANUAL
1
OBSERVE THE FOLLOWING PRECAUTIONS WHEN INSTALLING:
1. Mount the Camera in a position where it cannot be be interfered with either intentionally or accidentally.
2.
The mounting surface should be capable of supporting the weight of both the Camera and mounting brackets under all expected conditions of load, vibration and temperature.
3. The mounting brackets should be fitted in accordance with instructions and should observe all appropriate safety precautions & local building regulations.
4. Ensure the Camera is in the correct orientation, see FIG B above.
1 INSTALLING THE CAMERA HEAD
1.1 CONVERT DOME TO BALL PTZ CONFIGURATION
The RVX Series can be mounted as a dome or ball PTZ configuration. To convert the dome to ball PTZ remove the M4 button head screws with 2.5mm allen key provided. See FIG A below.
1.2 ATTACHING CAMERA TO BRACKET
BBRRAACCKKEETT IINNSSTTAALLLLAATTIIOONN::
Fixings to the various bracket types will depend on the fixing surface. It is important to use adequate quality fixings to safely support the complete Dome/Ball PTZ assembly. Fixing slots on a 4” PCD provide adequate clearance for 6mm bolts if attaching the Pedestal or Swan Mount to the mast.
FFLLYYIINNGG LLEEAADD:
:
If using a Swan/Pedestal/Pendant Mount, install the Fly Lead optionally through the Central Mounting Tube or via a 20mm Gland Entry Point. The Gland Entry is supplied with a 20 x 1mm thread to accomodate industry standard 20mm Glands.
FIG B MOUNTING ORIENTATION
X-SERIESTMUSER MANUAL
2
TECH SUPPORT COMMENT: It is important to match the menu software settings to the Camera
orientation (6.4.7) i.e. is the Camera hanging down or upright?
‘hanging down’ would be using one of the following bracket types :
swan [RV-SWAN] ,
pendant [RV-PNDT]
or wall [RV-WALL] - NOT SUITABLE FOR UPRIGHT MOUNTING
‘Upright’ would be using the pedestal bracket [RV-PED]
AATTTTAACCHHIINNGG CCAAMMEERRAA TTOO TTHHEE BBRRAACCKKEETT::
See Fig C & D below
1. Remove Mount Cover Plate.
2. Fully unscrew Hand Lock Nut.
3.
Offer Camera to Bracket. The Mounting Boss orientation is important and should match the picture in FIG C & D below. i.e The Flat Edge should be positioned to the rear and the Retaining Lugs engaged in the Boss Cut Outs.
4. If RV-PED (Pedestal) is being used support the Camera with hand when tightening the Hand Lock Nut - ensure the
Hand Lock Nut is fully tightened.
5. Ensure the Clearance is even throughout 360° rotation and the Camera is free moving.
6. Replace Mount Cover Plates.
1.3 BRACKET TYPES
RV-SWAN (Swan mount), RV-WALL (Wall mount), RV-PNDT (Pendant mount), RV-PED (Pedestal for mast/tower mount).
1.4 HOW TO CANTILEVER BALL/PTZ ARMS FORWARD
1. Remove pear shaped badge on each arm using small flat head screw driver.
2. Slightly loosen by one turn (BUT DO NOT REMOVE) the allen screws.
3. Cantilever the Ball Arms forward to ‘STOP’ position.
4. Tighten allen screws.
5. Replace badges (spares are provided).
6.
See Section 6.4.7 and from the SET UP MENU select either ‘UPRIGHT ARMS OUT’ or ‘HANGING ARMS OUT’
X-SERIESTMUSER MANUAL
3
2 HOW TO CONFIGURE THE CAMERA
2.1 REMOVING THE DIP SWITCH SCREW COVER
There are two rows of DIP switches located behind the large screw cap (see FIG 1 below). Use flat bladed screw driver to remove by turning anti-clockwise to unscrew.
2.1.2
DEFAULT DIP SWITCH SETTINGS All X-series™ cameras are factory defaulted to the following configuration:
BBV Up The Coax (UTC)
Camera address set to 1
RS485 termination set to ON
Real-time clock set to OFF
2.1.1 CAMERA ORIENTATION FOR SETTING DIP SWITCHES
CAUTION: Make sure the dip switches read right way up before configuring Camera. The word ‘protocol’
should be displayed as per picture see FIG 2 below
Ô ‘ON’ is down (away from the word protocol) Ô ‘OFF’ is up (toward the word protocol)
The switch numbers read 1 to 8 from left to right
THE BAUD & PROTOCOL SWITCHES (ROW A) WORK AS FOLLOWS:
SWITCH 1,2,3 PROTOCOL (SEE 2.3) SWITCH 4 & 5
BAUD RATE (2.4) SWITCH 6 NOT USED SWITCH 7 REAL TIME CLOCK (RTC) BATTERY ENABLE (2.6) SWITCH 8 RS485 TERMINATION ENABLE (2.5)
Use row B (FIG 2 below) to set the Camera address (2.2)
TABLE 1
X-SERIESTMUSER MANUAL
ROW ‘B’ DIP SWITCH ROW ‘B’ DIP SWITCH
CAMERA CAMERA ADDRESS
12345678 ADDRESS 12345678
not used 00000000 16 00001000
1 10000000 17 10001000 2 01000000 18 01001000 3 11000000 19 11001000 4 00100000 20 00101000 5 10100000 21 10101000 6 01100000 22 01101000 7 11100000 23 11101000 8 00010000 24 00011000
9 10010000 25 10011000 10 01010000 26 01011000 11 11010000 27 11011000 12 00110000 28 00111000 13 10110000 29 10111000 14 01110000 30 01111000 15 11110000 31 11111000
ROW ‘A’ DIP SWITCH
BAUD
1 2345678
9600 00
2400 10
4800 01
19200 11
2.4 SETTING THE CAMERA BAUD RATE
On row ‘A’ Use DIP switch numbers 4 and 5 to set the Baud rate. 0=off (up) & 1=ON (down). (See TABLE 3 below). For Baud Rate settings refer to user manual for the control equipment being used. NB Pelco D is normally 2400, Pelco P is 4800, Dennard is 9600.
TABLE 3
4
ROW ‘A’ DIP SWITCH
PROTOCOL
123 45678
BBV
Up the Coax 000
Pelco P 0 1 0
Pelco D 1 1 0
Dennard 1 0 1
Vista 0 0 1
Bosch 0 1 1
BBV422 1 1 1
2.3 SETTING THE CAMERA PROTOCOL
On row ‘A’ Set DIP switch numbers 1, 2 and 3 (See TABLE 2 below). ‘1’ represents ON (down) and ‘0 represents OFF (up).
TABLE 2
See www.redvisioncctv.com/support/downloads for camera address 32 to 255
2.2 SETTING THE CAMERA ADDRESS
See table TABLE 1 below for guidance on DIP switch setting for each Camera address. ‘0’ represents OFF (up) and ‘1’ represents ON (down).
5
X-SERIESTMUSER MANUAL
ROW ‘A’ DIP SWITCH
RTC
12345678
OFF 0
ON 1
ROW ‘A’ DIP SWITCH
TERMINATION
12345678
OFF 0
ON 1
2.6 REAL TIME CLOCK (RTC)
Row A, switch 7 sets the Camera’s internal real time clock. The RTC is used for setting the cameras’ internal clock & can be used for programming timed tours as well as RVX Series alarm functions (if using RVX-PSU-ALM16/W). The RTC battery can be set to ‘ON’ either at commissioning or installation stage. The default position is OFF (UP).
TABLE 5
2.7 REPLACING THE DIP SWITCH COVER
Before replacing the DIP switch screw cap, it is important to check it is free of dirt and grit. Thread
contamination could affect the waterproof seal.
The thread should be carefully aligned to prevent burring.
Using a large flat bladed screw driver turn the screw CLOCKWISE to tighten.
CAUTION: Termination switch should be set to ON (down) if:
Ô The Camera is being run on coax protocol Ô The Camera is the only one connected to the twisted pair Ô The Camera is last one on a daisy chain Ô An alarm module has been fitted to the Camera power supply & is running 485 protocol
The termination switch should be OFF(up) if:
More than one Camera is connected on a DAISY CHAIN but it is NOT the last in line [The exception would be if an alarm module were installed. If this were the case, the Camera should be terminated (ON/DOWN) and the alarm module would un-terminated (OFF/UP) see section 4.5 Setting the Alarm Module RS485 Termination].
2.5 SETTING THE CAMERA RS485 TERMINATION
The default position is ON (down).
TABLE 4
X-SERIESTMUSER MANUAL
6
WARRANTY & SAFETY NOTICE: DISCONNECT ALL POWER BEFORE
OPENING OR WORKING ON THE POWER SUPPLY UNIT. INSTALLATION MUST BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON.
3 POWER SUPPLY INSTALLATION & SETUP
Camera Warranty is void unless it is installed using one of the following Redvision power supplies and a Redvision supplied fly lead (Composite cable): Using the wrong type of 3rd party PSU could compromise safety and damage the camera unit.
RVX-PSU RVX-PSU-ALM16 RVX-PSU-ALAM16-W
The RVX Power Supplies are compatible with the following X-Series Cameras: RVX18, RVX18-W, RVX18-IR, RVX18-IR-W, RVX28, RVX28-W, RVX28-IR, RVX28-IR-W.
COMPOSITE CABLE: A pre-made composite cable with a 7 way female amphenol connector is supplied with all Redvision brackets. The female connector connects directly to the male connector on the RVX PTZ Camera housing. Follow the colour coding idents as shown in table 3.2.2 for terminating the fly lead in the power supply.
CABLE/ PIN OUT TABLE
PIN No. CABLE/WIRE
1 Video Signal 2 Video Screen 3 White 4 Orange 5 NOT USED 6 RED 24Vdc
7 (Centre) BLACK 0Vdc
3.2 VOLTAGE
Input: 110V/230V Output: 24Vdc @ 2A
3.3 RVX-PSU INTERNAL CONNECTIONS
3.3.1 MAINS INPUT
TABLE 6
3.1 REDVISION POWER SUPPLY (RVX-PSU)
1. Mount the Redvision PSU in a position so it cannot be interfered with intentionally or accidentally. Ideally use a lockable cabinet .
2.
Securely fix the Redvision PSU using appropriate size screws and ensure the cable glands have sufficient clearance to allow the cables to enter.
3. All cables should be channelled through the appropriate sized gland holes.
4. It is recommended that a good quality screened data pair or coax is used for transmitting data signal.
5. If the Redvision alarm module and or wireless PIR module is to be used refer to section 4 and 5.
6. If Star configuration is used it is recommended a suitable Star Card interface is used.
7. Only use Redvision supplied umbilical cables for connecting
the X-SERIES ball/PTZ dome & Redvision PSU. Warranty will be void if these cables are extended between the PTZ/dome unit and PSU. Extending cables could also compromise safety.
METAL COVER
FIG 7
4 CORNER FIXING HOLES
MAINS INPUT
DOME CONNECTIONS
EARTH TERMINAL
RS485 DIAGNOSTIC LEDS
CONTROL CONNECTIONS
The Redvision power supply (part code: RVX-PSU) outputs 24V DC & is supplied in a weather proof ABS box rated IP67.
NOTE: Earth connection requires 4mm red spade loop (supplied with PSU) to be fitted by engineer at installation. SSAAFFEETTYY:: EENNSSUURREE MMAAIINNSS IINNPPUUTT && EEAARRTTHH CCOONNNNEECCTTIIOONNSS AARREE SSEECCUURREELLYY SSTTRRAAIINN RREELLIIEEVVEEDD.
.
PCB IDENT MAINS POWER
* LIVE LIVE (BROWN) 110/230Vac Connection via 2 way terminal block
* NEUTRAL NEUTRAL (BLUE) Connection via 2 way terminal block
* EARTH GREEN/YELLOW Connection via terminal screw
X-SERIESTMUSER MANUAL
7
3.3.2 CONNECTIONS TO CAMERA - 8 WAY TERMINAL BLOCK
TABLE 7
PCB IDENT CONTROL CONNECTIONS
AUX-C
AUX-E Not used
VIDEO COAX signal (BNC P6)
V-GND COAX screen
RS485(A) RS485(A)
RS485(B) RS485(B)
24V
0V
PCB IDENT UMBILICAL LEAD TO CAMERA
N/C Normally Closed
N/C Normally Closed
VIDEO Coax signal (BNC 7)
V-GND Coax screen
RS485(A) White
RS485(B) Orange
+24V Red
0V Black and cable screen
3.3.3 CONNECTIONS TO CONTROL - 8 WAY TERMINAL BLOCK
TABLE 8
STATUS DESCRIPTION
* RED/OFF GREEN/OFF DISCONNECTED
* RED/OFF GREEN/ON OK IDLE
* RED/FLASH GREEN/FLASH OK - TRAFFIC PASSING
* RED/ON GREEN/ON A/B REVERSED
3.3.4 RS485 DIAGNOSTIC LEDs
TABLE 9
PCB IDENT DESCRIPTION
* F1 Mains input fuse 3.15A - Anti Surge*
F2 Camera fuse 3.15A - Fast Blow
3.3.5 FUSE PROTECTION
TABLE 10
X-SERIESTMUSER MANUAL
8
4 RVX-PSU-ALM16 (PSU WITH ALARM MODULE)
4.1 VOLTAGE
Input: 100-230V 47-63Hz 80VA MAX Output:
24Vdc @ 2A
4.2 RVX-PSU-ALM16 INTERNAL CONNECTIONS
4.2.1 MAINS INPUT
TABLE 11
NOTE: Earth connection requires 4mm red spade loop (supplied with PSU) to be fitted by engineer at installation. SSAAFFEETTYY:: EENNSSUURREE MMAAIINNSS IINNPPUUTT && EEAARRTTHH CCOONNNNEECCTTIIOONNSS AARREE SSEECCUURREELLYY SSTTRRAAIINN RREELLIIEEVVEEDD.
.
WARRANTY & SAFETY NOTICE: DISCONNECT ALL POWER BEFORE OPENING OR WORKING
ON THE RVX-PSU-ALM16 POWER SUPPLY UNIT WITH EMBEDDED ALARM CARD. THIS PROTECTS HIGH VOLTAGE COMPONENTS. INSTALLATION MUST BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON.
FIG 8
CONFIG DIP SWITCH (S5)
METAL COVER
ALARM OUTPUTS
ALARM INPUTS
MAINS INPUT
DOME CONNECTIONS
CONTROL CONNECTIONS
EARTH TERMINAL
S3 S4
PCB IDENT MAINS POWER
* LIVE LIVE (BROWN) 110/230Vac Connection via 2 way terminal block
* NEUTRAL NEUTRAL (BLUE) Connection via 2 way terminal block
* EARTH GREEN/YELLOW Connection via earth terminal screw
X-SERIESTMUSER MANUAL
9
4.2.2 CONNECTIONS TO CAMERA - 8 WAY TERMINAL BLOCK
TABLE 12
PCB IDENT CONTROL CONNECTIONS
AUX-C
AUX-E
VIDEO COAX signal (BNC P6)
V-GND COAX screen
RS485(A) RS485(A)
RS485(B) RS485(B)
24V Red
0V Black and cable screen
PCB IDENT UMBILICAL LEAD TO CAMERA
N/C Normally Closed
N/C Normally Closed
VIDEO Coax signal (BNC 7)
V-GND Coax screen
RS485(A) White (+IVE)
RS485(B) Orange
+24V Red
0V Black and cable screen
4.2.3 CONNECTIONS TO CONTROL - 8 WAY TERMINAL BLOCK
TABLE 13
STATUS DESCRIPTION
* RED/OFF GREEN/OFF DISCONNECTED
* RED/OFF GREEN/ON OK IDLE
* RED/FLASH GREEN/FLASH OK - TRAFFIC PASSING
* RED/ON GREEN/ON A/B REVERSED
4.2.4 RS485 DIAGNOSTIC LEDs
TABLE 14
PCB IDENT DESCRIPTION
* F1 Mains input fuse 3.15A - Anti Surge*
F2 Camera fuse 3.15A - Fast Blow
4.2.5 FUSE PROTECTION
TABLE 15
4.3 ALARM MODULE DIP SWITCH SETTINGS
Refer to S5 ‘CONFIG DIP SWITCH’ (see diagram in FIG 8, page 8) for Setting Protocol, Baud Rate & RS485 termination. Switches 6 & 7 are NOT used.
X-SERIESTMUSER MANUAL
10
4.3.1 PROTOCOL - ALARM MODULE
TABLE 16
4.3.2 BAUD RATE - ALARM MODULE
TABLE 17
PPrroottooccooll BBaauudd RRaattee RRSS 448855 TTeerrmmiinnaattiioonn
DDIIPP SSWWIITTCCHH NNoo..
1 23 4 5 6 7 8
BBV Coax 000 NOT NOT Pelco P
010 USED USED
Pelco D
1 10
Dennard 101 Vista 0 01
Bos ch/ Forward Vision 011
BBV 422 111
PPrroottooccooll BBaauudd RRaattee RRSS 448855 TTeerrmmiinnaattiioonn
DDIIPP SSWWIITTCCHH NNoo..
123 4 5 6 7 8
2400 10 NOT NOT 4800
01 USED USED
9600
00
19200 11
4.3.3 RS485 TERMINATION - ALARM MODULE See 4.5.1 for TERMINATION SCENARIOS
TABLE 18
4.4 ALARM INPUTS
1-16 sets of volt free Contacts which can be configured using the onboard 8 way dip S3 & S4 (FIG 8, page 8 ) for either normally open or normally closed operation. See
44..5
5
below.
4.4.1
ALARM INPUT GROUNDS 16 Alarm Inputs are provided to match 16 Ground Inputs.
PPrroottooccooll BBaauudd RRaattee RRSS 448855 TTeerrmmiinnaattiioonn
DDIIPP SSWWIITTCCHH NNoo..
123 4 5 6 7 8
OFF 000 NOT NOT 0 ON 010 USED USED 1
TECH SUPPORT COMMENT: Alarm module PROTOCOL should be set to the same PROTOCOL as the camera.
TECH SUPPORT COMMENT: Alarm module BAUD RATE should be set to the same BAUD RATE as the camera.
PELCO D normally uses 2400. PELCO P normally uses 4800.
X-SERIESTMUSER MANUAL
11
4.5 NORMALLY OPEN/NORMALLY CLOSED ALARM INPUTS
See S3 & S4 on the RVX-PSU-ALM16 PCB (see diagram FIG 8, page 8)
TABLE 19
4.5.1 TERMINATION SCENARIOS If control is over coax protocol, both the Camera and Alarm Module should be terminated.
If control is over RS485 and the system is running a Star Card configuration, both the Camera and Alarm Module should be terminated.
COAX PROTOCOL
COAX PROTOCOL
PSU &
ALARM MODULE
TERMINATED
DVR
RV-DOME
TERMINATED
RV-DOME
TERMINATED
PSU
PSU &
ALARM MODULE
TERMINATED
DVR
RV-DOME
TERMINATED
RV-DOME
TERMINATED
PSU
STAR RS 485
STAR RS 485
STAR
CARD
4.4.2 RELAY OUTPUTS (VOLT FREE) There are 3 relay outputs NO/NC 0V output: Alarms, Wash and Aux. ALARMS are tied into ALARM INPUTS. WASH is activated by a wash command or by user defined preset. AUX can be triggered by ACTIVE ALARMS or IR NIGHT MODE SWITCHING.
S3 NO/NC ALARMS 1-8 S4 NO/NC ALARMS 9-16
If control is over RS485 and the system is running a Daisy Chain configuration then;
(A) If the Camera and Alarm Module is the last in line, both the Camera and Alarm Module should be terminated.
RS 485
DAISY CHAIN
X-SERIESTMUSER MANUAL
12
PSU &
ALARM MODULE
TERMINATED
DVR
RV-DOME
UN-TERMINATED
RV-DOME
UN-TERMINATED
RV-DOME
TERMINATED
PSUPSU
RS 485
DAISY CHAIN
(B) ) If the Camera and Alarm Module is NOT the last in line, the Camera should be terminated and the Alarm Module un-
Terminated. The Alarm Module takes over the termination from the Camera i.e. it (the Alarm Module) should be un­terminated!
PSU &
ALARM MODULE
UN-TERMINATED
DVR
RV-DOME
UN-TERMINATED
RV-DOME
UN-TERMINATED
RV-DOME
TERMINATED
RV-DOME
TERMINATED
END OF LINE
PSUPSUPSU
5 WIRELESS ALARM CARD (WIRELESS PIR DETECTOR)
5.1 FACTORY FITTED WIRELESS CARD (RV-PSU-ALM16-W)
The Redvision Wireless Card is compatible with the Redvision Wireless PIR, Luminite Genesis Range and the Redwall Wireless Transmitter Module Part Code WF434T, (wireless enables Redwall PIRs).
This PSU is compatible with the following RVX SERIES PTZs: RRVVXX1188,, RRVVXX1188--IIRR,, RRVVXX1188--WW,, RRVVXX1188--IIRR--WW,, RRVVXX2288,, RRVVXX2288--IIRR,, RRVVXX2288--WW,, RRVVXX2288--IIRR--WW.
.
Refer to
44..22
for RVX-PSU INTERNAL CONNECTIONS &
44..3
3
for ALARM MODULE DIP SETTINGS.
WARRANTY & SAFETY NOTICE: DISCONNECT ALL POWER BEFORE OPENING OR WORKING ON
THE POWER SUPPLY UNIT AND ALARM CARD. WIRELESS ALARM CARDS SHOULD NOT BE HOT SWAPPED OR INSTALLED WHILST THE POWER IS LIVE. INSTALLATION MUST BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON.
5.1.1 CONFIGURING WIRELESS ALARM MODULE ALARM
INPUTS The RVX-PSU-ALM16-W has 16 Alarm Inputs. These can either be used as either HARDWIRED or WIRELESS Alarm Inputs, or a combination of both, e.g. 8 HARDWIRED & 8 WIRELESS.
FIG 8
X-SERIESTMUSER MANUAL
13
1 to 3 dip switches are not used & should be left ‘ON’ (UP)
Switches 4 to 8 (Dome Head Site Code) provide up to 32 (1 to
16 shown in TABLE 19) channels of wireless transmission to enable alarm activation.
The transmission needs to be matched between the Dome Head
Site Code on the wireless alarm module & the Site Code within the PIR detector (see separate PIR installation guide supplied with the PIR).
One or more domes wil respond to any wireless PIR within range
providing the Dome Head Site Code & corresponding PIR Site Code match.
SW1
45678
1
s ssss
2 s ssst 3 s sst s 4 s sstt 5 s s t ss 6 s s t s t 7 s s tts 8 s s ttt 9 s t sss 10 s t sst 11 s t s t s 12 s t s tt 13 s ttss 14 s tts t 15 s ttts 16 s tttt
UP = s
DOWN = t
TABLE 19
DIP SWITCH SETTINGS The WIRELESS Alarm Module has a single 8 Way DIP SWITCH. (See FIG 8 below).
CONFIG DIP SWITCH (S5)
AERIAL
NO/NC ALARMS (S3 & S4)
WIRELESS 8 WAY DIP SWITCH
METAL COVER
ALARM OUTPUTS
ALARM INPUTS
MAINS INPUT
DOME CONNECTIONS
CONTROL CONNECTIONS
EARTH TERMINAL
5.1.2 POSITIONING OF RV-PSU-ALM16-W To maximise the transmission range install the PSU externally with the aerial pointing through the gland towards the ground. An optional booster aerial (RV-AE434) can be used to significantly improve signal and range. It is recommended to use the booster aerial if the PIRs are installed on metal clad buildings.
5.2 IF RETRO FITTING WIRELESS ALARM RECEIVER
If Retro-Fitting a wireless alarm receiver card onto an existing 16 way alarm module (RVX-PSU-ALM16-W) observe the following steps:
A) ISOLATE POWER FROM PSU
- YOU CANNOT HOT SWAP WIRELESS ALARM MODULE. B) Align Wireless Alarm Module with P3 Connector and secure with M3 fixings. E) Thread aerial antenna through gland and connect to BNC on Wireless Receiver. F) See Table 19, 5.1.1 for DIP switch settings.
X-SERIESTMUSER MANUAL
14
6 NAVIGATING THE MENUS
6.1 MENU NAVIGATION - FLOW CHART
Use joystick/Arrow keys to navigate the menu options. See FIG 9, page 15.
6.1.1
ACCESS MAIN MENU FROM 3rd PARTY CONTROLLERS As most keyboards differ in the way they access the Camera’s MAIN MENU it is recommended the user refers to the specific keyboard manual for the control system they are using. See Table 20, below, for examples.
6.1.2 EXIT MENU Move the joystick or arrow keys to the left from all levels to exit the Camera main menu. Any changes made will be saved permanently when the menu is exited. The message ‘SAVED OK’ will appear to confirm changes have been saved.
6.2 LOGIN
Use joystick/Arrow keys to navigate the menu options.
Ô From main menu move joystick/arrow4 TO LOGIN MENU Ô MOVE 3456 ENTER DIGIT PASSWORD Ô MOVE 3TO SAVE & EXIT
A message will display to confirm successful login or not.
DDeeffaauulltt PPAASSSSWWOORRDDSS:
:
TECHNICIAN 999900 (Full access) SUPERVISOR
555500 (partial access)
OPERATOR 111100 (limited access)
To change a password see 6.4.5.4 & view permissions rights see 6.4.5
6.3 LOGIN EXPIRY
After 5 minutes of user inactivity the system times out and the Camera reverts to its previous activity. Access to the menu will be denied unless password is re-entered.
6.4 SET UP
The ‘SET UP’ is the main sub menu for accessing Camera configuration settings. See 6.4.1 to 6.4.10.
LOGIN > MAIN MENU >
SSEETT UUP
P
6.4.1 ENTER DATE & TIME
Ô LOGIN > MAIN MENU >
SSEETTUUPP >
>
ENTER DATE/TIME
Ô MOVE 3456 TO SET DATE DD:MM:YY & TIME HH:MM:SS Ô MOVE 3TO SAVE & EXIT
BBV
DTX400
BBV 1000
DTX 1000
PELCO
ACCESS MAIN CAMERA MENU
Press & hold # then press 1
Press & hold SHIFT then press 1
Press hold # then press wash key
Press & hold # then wash key
Save 95 Preset
CONTROLLER
Some common examples for accessing the Camera main menu and commands are as follows:
TABLE 20
IR MODEIR MODE
LOW LIGHT MODE
LIGHT SENSING
MANUAL
TIMED
SELECT NIGHT MODE
HANGING
HANGING ARMS OUT
UPRIGHT
UPRIGHT ARMS OUT
OFF
EXPOSURE COMPENSATION
SHUTTER SPEED
NIGHT MODE SWITCHING
JOYSTICK FOCUS MODE
EXPOSURE COMPENSATION
SHUTTER SPEED
COLOUR/MONO
PRESET FOCUS MODE
ON LEVEL
NIGHT MODE SWITCHING
OFF LEVEL
AUTO SWITCH DELAY
ON TIMES
IR LAMP POWER
LOG IN
SET UP 6.4
PASSWORDS
DATUM CHECK
CAMERA ORIENTATION
INSTALLATION DATE
CLEAR SETTINGS
DIAGNOSTICS
VIDEO GAIN
VIDEO LIFT
IRIS KEY USAGE
DIGITAL ZOOM
INVERT CAMERA IMAGE
MIRROR CAMERA IMAGE
CROSS HAIR
JOYSTICK FOCUS MODE
EXPOSURE COMPENSATION
SHUTTER SPEED
PRESET FOCUS MODE
ADVANCED CONFIGURATION
ADVANCED CONFIGURATION
CLEAR TOURS
CLEAR PRESETS
CLEAR CONFIGURATION
CLEAR PRIVACY
CLEAR EVERYTHING
CLEAR ALARM SETTINGS
REBOOT
LOW LIGHT MODE SETTINGS
JOYSTICK FOCUS MODE
EXPOSURE COMPENSATION
SHUTTER SPEED
FOCUS CORRECTION (OFF)
PRESET FOCUS MODE
ADVANCED CONFIGURATION
IR MODE SETTINGS
DAY MODE SETTINGS
NIGHT MODE
7
ENTER DATE/TIME
DAYLIGHT SAVING
LANGUAGE
DISPLAY
DATE/TIME POSITION
CAMERA TITLE
CAMERA TITLE SCREEN POSITION
PRESET TEXT POSITION
TEXT BACKGROUND
SHOW PRESETS DURING TOURS
MAIN MENU
FIG 9
6.1
MENU NAVIGATION - FLOW CHART
CAMERA SETTINGS
8
JOYSTICK CURVE
ZOOM RATIO
PAN LIMITS
TILT LIMITS
SHORTCUTS
AUX RELAY FUNCTION
COMPATIBILITY MODE
WIPER TIME OUT
INTERMITTENT
WIPER SHORTCUT PRESET
WASH SHORTCUT PRESET
WIPER/WASH SHORTCUT PRESET
NIGHT MODE SHORTCUT PRESETS
STANDARD
BBV TX1000/1500
JOYSTICK SPEED
EDIT PRESETS
SET PRESET
PRESET SPEED
RESTORE TO NUMBER
TIMED RESTORE WEEKDAY
TIMED RESTORE WEEKEND
RESTORE MODE
RESTORE DELAY
ACTIVE TIME WEEKDAY
ACTIVE TIME WEEKENDS
ACTION WHEN ACTIVE
ACTION NUMBER
ACTION WHEN MASKED
TITLE
NEW ALARM DWELL
SHOW ALARM INFO
CLEAR COUNTERS
TITLE
INITIALISE TOUR
EDIT TOUR
DWELL
SPEED
TOUR ORDER
X-SERIESTMUSER MANUAL
16
WIPER
TOURS TOURS 1 - 8
RESTORE
PRESET
ENABLE ALARMS
ALARM OVERRIDE TIME
ALARM CYCLE TIME
SET OR CLEAR MASK
ZOOM THRESHOLD
EDIT MASK
EDIT ALARM
JOYSTICK 9
PRESETS & TOURS 10
PRIVACY 11
ALARMS 12
FREEZE FRAME DURING SEEK
X-SERIESTMUSER MANUAL
17
6.4.2 DAYLIGHT SAVING Default setting is AUTO.
Ô LOGIN > MAIN MENU >
SSEETTUUPP >
>
DAYLIGHT SAVING
Ô MOVE 3456 TO SET AUTO, OFF (+0), ON (+1) Ô MOVE 3TO SAVE & EXIT
6.4.3 LANGUAGE OPTIONS Localise the display messages into the following language options:
English
Spanish
German
French
Portuguese
Ô LOGIN USING TECHNICIAN PASSCODE > MAIN MENU > LANGUAGES Ô MOVE 56 TO CHANGE LANGUAGE Ô MOVE 3TO SAVE & EXIT
6.4.4 DISPLAY
6.4.4.1 DATE/TIME POSITION User has the option of inserting the on screen position of the date/time
Ô LOGIN > MAIN MENU >
SSEETTUUPP >> DDIISSPPLLAAY
Y
> DATE & TIME POSITION
Ô MOVE 56 TO MOVE THE DISPLAY POSITION Ô MOVE 3TO SAVE & EXIT
Default is OFF (nothing displayed).
6.4.4.2 CAMERA TITLE
Ô LOGIN > MAIN MENU >
SSEETTUUPP >> DDIISSPPLLAAY
Y
> CAMERA TITLE > TITLE
Ô MOVE 56 TO CHANGE ALPHANUMERIC CHARACTERS Ô MOVE 3TO SAVE & EXIT
6.4.4.3 CAMERA TITLE SCREEN POSTION
Ô LOGIN > MAIN MENU >
SSEETTUUPP >> DDIISSPPLLAAY
Y
> CAMERA TITLE > POSITION ON SCREEN
Ô MOVE 56 TO MOVE SCREEN POSITION Ô MOVE 3TO SAVE & EXIT
6.4.4.4 SHOW PRESET TITLES DURING TOURS
Ô LOGIN > MAIN MENU >
SSEETTUUPP >> DDIISSPPLLAAY
Y
> SHOW PRESET TITLE DURING TOURS
Ô MOVE 56 SELECT YES/NO Ô MOVE 3TO SAVE & EXIT
6.4.4.5 PRESET TEXT POSITION
Ô LOGIN > MAIN MENU >
SSEETTUUPP >> DDIISSPPLLAAYY >
>
SHOW PRESET TEXT POSITION
Ô MOVE 56 TO CHANGE POSITION Ô MOVE 3TO SAVE & EXIT
TECH SUPPORT COMMENT: It is important users do not set everything to the same corner of the screen
X-SERIESTMUSER MANUAL
18
6.4.4.6 TEXT BACKGROUND
Ô LOGIN > MAIN MENU >
SSEETTUUPP >> DDIISSPPLLAAYY
> TEXT BACKGROUND
Ô MOVE 56 SELECT TO CHANGE TEXT BACKGROUND Ô MOVE 3TO SAVE & EXIT
6.4.5 PASSWORDS
Ô LOGIN > MAIN MENU >
SSEETTUUPP
> PASSWORDS
6.4.5.1
OPERATOR (LIMITED ACCESS) Default password is 111100. TO CHANGE see 6.4.5.4 Permission rights:
Date/time
Daylight saving
Presets
Tours
Display options
Language options
Datum check
6.4.5.2 SUPERVISOR (PARTIAL ACCESS) Default password is 555500. TO CHANGE see 6.4.5.4 Permission rights: All operator permissions plus:
Clear privacy
Set privacy
Alarms
6.4.5.3 TECHNICIAN (FULL ACCESS) Default password is 999900. TO CHANGE see 6.4.5.4 Permission rights: All operator & supervisor permissions plus:
Camera titles
Set passwords
Installation date
Clear settings
Reboot
Diagnostics
IR modes
Camera settings
Joystick settings
Wiper settings
6.4.5.4 TO CHANGE PASSWORD
Ô LOGIN > MAIN MENU >
SSEETTUUPP >
>
PASSWORDS
Ô LOGIN USING TECHNICIAN PASSCODE Ô MOVE 3456 TO SELECT LEVEL TO BE CHANGED Ô MOVE 3456 TO CHANGE PASSWORD NUMBER Ô MOVE 3TO SAVE & EXIT
6.4.6 DATUM CHECK The Redvision X-Series Camera is programmed to perform a datum check every 24 hours. The Camera will pan and tilt for a few seconds while it undergoes a self diagnostic test and re-checks its alignment. When the process is complete the Camera will revert to its previous activity including any tours with presets.
TECH SUPPORT COMMENT: It is recommended to leave the Camera in the default 24 hour option
X-SERIESTMUSER MANUAL
19
6.4.7 CAMERA ORIENTATION The Camera orientation automatically sets the maximum tilt up/down positions depending on whether the Camera is in upright or hanging down mode. The maximum tilt restrictions can be deactivated to allow full tilt movement. See 9.6.
Ô LOGIN > MAIN MENU >
SSEETTUUPP >>
CAMERA ORIENTATION
Ô MOVE 56 TO SELECT CAMERA ORIENTATION > HANGING, HANGING ARMS OUT, UPRIGHT, UPRIGHT ARMS OUT Ô MOVE 3TO SAVE & EXIT
6.4.8 DATE AND TIME OF INSTALLATION
Ô LOGIN > MAIN MENU >
SSEETTUUPP >
>
INSTALLATION DATE
Ô MOVE 3456 TO ENTER INSTALLATION DATE/TIME Ô MOVE 3TO SAVE & EXIT
6.4.9 CLEAR SETTINGS
6.4.9.1 CLEAR CONFIGURATION Use this option to partially clear configuration settings. All configuration changes except for tours and presets will be reset to factory default.
Ô LOGIN > MAIN MENU >
SSEETTUUPP >
>
CLEAR SETTINGS > CLEAR CONFIGURATION
Ô MOVE 56 TO SELECT YES/NO Ô MOVE 3TO SAVE & EXIT
6.4.9.2 CLEAR PRESETS Use this option to clear ALL stored presets.
Ô LOGIN > MAIN MENU >
SSEETTUUPP >
>
CLEAR SETTINGS > CLEAR PRESETS
Ô MOVE 56 TO SELECT YES/NO Ô MOVE 3TO SAVE & EXIT
6.4.9.3 CLEAR TOURS Use this option to clear ALL stored tours.
Ô LOGIN > MAIN MENU >
SSEETTUUPP >
>
CLEAR SETTINGS > CLEAR TOURS
Ô MOVE 56 TO SELECT YES/NO Ô MOVE 3TO SAVE & EXIT
6.4.9.4 CLEAR PRIVACY MASKS Use this option to clear ALL privacy masks.
Ô LOGIN > MAIN MENU >
SSEETTUUPP >
>
CLEAR SETTINGS > CLEAR PRIVACY MASKS
Ô MOVE 56 TO SELECT YES/NO Ô MOVE 3TO SAVE & EXIT
6.4.9.5 CLEAR ALARM SETTINGS
Ô LOGIN > MAIN MENU >
SSEETTUUPP >
>
CLEAR SETTINGS > CLEAR ALARM SETTINGS
Ô MOVE 56 TO SELECT YES/NO Ô MOVE 3TO SAVE & EXIT
6.4.9.6 CLEAR EVERYTHING This option clears ALL settings but does not reboot the camera, therefore leaving video picture.
Ô LOGIN > MAIN MENU >
SSEETTUUPP >>
CLEAR SETTINGS > CLEAR EVERYTHING
Ô MOVE 56 TO SELECT YES/NO Ô MOVE 3TO SAVE & EXIT
6.4.9.7 REBOOT To soft restart the camera (equivalent to power cycling).
Ô LOGIN > MAIN MENU >
SSEETTUUPP >>
CLEAR SETTINGS > REBOOT
Ô MOVE 56 TO SELECT YES/NO Ô MOVE 3TO SAVE & EXIT
7 NIGHT MODE
7.1 SELECT NIGHT MODE
IR Mode Low Light Mode
Ô LOGIN > MAIN MENU > NIGHT MODE > SELECT NIGHT MODE Ô MOVE 56 TO SELECT EITHER IR MODE OR LOW LIGHT MODE Ô MOVE 3TO SAVE & EXIT
7.2 NIGHT MODE SWITCHING
Light sensing Manual Timed
Ô LOGIN > MAIN MENU > NIGHT MODE > NIGHT MODE SWITCHING Ô MOVE 56 TO SELECT EITHER LIGHT SENSING, MANUAL OR TIMED Ô MOVE 3TO SAVE & EXIT
7.3 ON LEVEL
Light level at which the camera switches to either IR mode or Low Light Mode (Low light mode can be set to force camera to stay in colour or mono without infra red) Default setting is 50. On Level must be lower than OFF level. The lower the number the darker the light needs to be in order for the camera to switch to IR mode or Low Light Mode..
Ô LOGIN > MAIN MENU > NIGHT MODE > ON LEVEL Ô MOVE 56 CHANGE VALUE Ô MOVE 3TO SAVE & EXIT
7.4 OFF LEVEL
Light level at which the camera switches to DAY MODE Colour.
Ô LOGIN > MAIN MENU > NIGHT MODE > OFF LEVEL Ô MOVE 56 CHANGE VALUE Ô MOVE 3TO SAVE & EXIT
7.5 AUTO SWITCH DELAY
The AUTO SWITCH DELAY time can be set in seconds. The delay prevents the IR pods & Camera responding to short term effects e.g. car headlights, which may cause the IR pods & Camera to switch to mono.
Ô LOGIN > MAIN MENU > NIGHT MODE > AUTO SWITCH DELAY Ô MOVE 56 CHANGE VALUE (1 - 999 seconds) Ô MOVE 3TO SAVE & EXIT
X-SERIESTMUSER MANUAL
20
6.4.10 DIAGNOSTICS There are five diagnostic screens which display useful information for the technician and remote help diagnostics for Redvision’s technical support helpdesk. They are not configurable.
To access the diagnostic screens.
Ô LOGIN > MAIN MENU >
SSEETTUUPP >
>
DIAGNOSTICS
Ô MOVE 56 TO SELECT SYSTEM, STATUS, CAMERA, TELEMETRY OR MOTORS Ô MOVE 3TO SAVE & EXIT
To ‘exit’ motors, it is necessary to ‘recall’ the menu see 6.1.1
TECH SUPPORT COMMENT: *The numerical value is an arbitrary figure and not a lux measurement.
Solid block = Infra red ON No Block = Infra red OFF
X-SERIESTMUSER MANUAL
21
7.6 ON TIMES
The IR PODS (RVX-IR version) & Camera can be programmed to switch on/off colour/mono at pre-determined times. There are 24 block positions representing each hour of the day.
Ô LOGIN > MAIN MENU > NIGHT MODE > IR ON TIMES Ô MOVE 56 TO SELECT HOUR TIME BLOCKS Ô MOVE 3TO SAVE & EXIT
7.7 INFRA RED POWER (RVX-IR VERSION ONLY)
The infra-red intensity can be varied. Default is set to 100%.
Ô LOGIN > MAIN MENU > NIGHT MODE > IR POWER Ô MOVE 56 CHANGE VALUE Ô MOVE 3TO SAVE & EXIT
8 CAMERA SETTINGS
Use CAMERA SETTINGS to optimise the Sony module performance for specific day or night-time conditions.
1. Day Settings – default day time colour & IR PODS off (RVX-IR models) (see 8.1).
2. Night Mode settings – camera is either in IR Mode or Low Light Mode (see 7.1).
8.1 DAY MODE SETTINGS
8.1.1 SHUTTER SPEED Adjust the shutter speed to achieve greater light sensitivity. Default is 1/215
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > SHUTTER SPEED Ô MOVE 56 TO CHANGE SHUTTER SPEED 1/1 to AUTO Ô MOVE 3TO SAVE & EXIT
8.1.2 EXPOSURE COMPENSATION Adjustment for unusual lighting distribution. Compensation can be either positive (additional exposure) or negative (reduced exposure). Default setting = 0
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > EXPOSURE COMPENSATION Ô MOVE 56 TO ADJUST EXPOSURE LEVEL BETWEEN +7 AND -7 Ô MOVE 3TO SAVE & EXIT
8.1.3 JOYSTICK FOCUS MODE There are two settings AUTO focus & MANUAL focus. Default setting for day is auto.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > JOYSTICK FOCUS MODE Ô MOVE 56 TO SELECT AUTO OR MANUAL Ô MOVE 3TO SAVE & EXIT
8.1.4 PRESET FOCUS MODE
((SSOONNYY MMOODDUULLEE)
)
There are two modes: auto & stored. Default setting for day is auto.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > PRESET FOCUS MODE Ô MOVE 56 TO SELECT AUTO OR STORED Ô MOVE 3TO SAVE & EXIT
8.1.5. ADVANCED CONFIGURATION
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > ADVANCED CONFIGURATION
8.1.5.1 ZOOM LIMIT
((SSOONNYY MMOODDUULLEE)
)
This can be adjusted from 10% to 100%
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > ZOOM LIMIT Ô MOVE 56 TO CHANGE ZOOM LIMIT (10% to 100%) Ô MOVE 3TO SAVE & EXIT
X-SERIESTMUSER MANUAL
22
8.1.5.2 BACKLIGHT COMPENSATION
The ability of a Camera to compensate in cases where a subject with a large amount of background light would otherwise be obscured by blooming or silhouetting. Can be turned ON or OFF. Default is off.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > ADV CONFIG > BACKLIGHT COMPENSATION Ô MOVE 56 TO SELECT ON/OFF Ô MOVE 3TO SAVE & EXIT
8.1.5.3 IMAGE STABILISER
((SSOONNYY MMOODDUULLEE)
)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > ADV CONFIG > IMAGE STABILISER Ô MOVE 56 TO SELECT ON/OFF Ô MOVE 3TO SAVE & EXIT
8.1.5.4 WHITE BALANCE
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > ADV CONFIG > WHITE BALANCE Ô MOVE 56 TO SELECT OPTION Ô MOVE 3TO SAVE & EXIT
8.1.5.5 NOISE REDUCTION (PARKED)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > ADV CONFIG >
NNOOIISSEE RREEDDUUCCTTIIOONN ((PPAARRKKEEDD)
)
Ô MOVE 56 TO ADJUST 0 to 5 (0 IS DEFAULT) Ô MOVE 3TO SAVE & EXIT
8.1.5.6 NOISE REDUCTION (MOVING)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > ADV CONFIG >
NNOOIISSEE RREEDDUUCCTTIIOONN ((MMOOVVIINNGG)
)
Ô MOVE 56 To ADJUST 0 to 5 (2 is DEFAULT) Ô MOVE 3TO SAVE & EXIT
8.1.5.7 SPOT AE
((SSOONNYY MMOODDUULLEE)
)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > ADV CONFIG >
SSPPOOTT AAE
E
Ô MOVE 56 TO SELECT ON/OFF Ô MOVE 3TO SAVE & EXIT
8.1.5.8 APERTURE CORRECTION
((SSOONNYY MMOODDUULLEE)
)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > ADV CONFIG >
AAPPEERRTTUURREE CCOORRRREECCTTIIOON
N
Ô MOVE 56 TO SELECT 1 to 16 (9 IS DEFAULT) Ô MOVE 3TO SAVE & EXIT
8.1.5.9 GAIN LIMIT
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > ADV CONFIG >
GGAAIINN LLIIMMIIT
T
Ô MOVE 56 TO CHANGE VALUE Ô MOVE 3TO SAVE & EXIT
8.1.5.10 CHROMA CORRECTION
((HHIITTAACCHHII MMOODDUULLEE)
)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DAY MODE SETTINGS > CHROMA CORRECTION Ô MOVE 56 TO CHANGE VALUE Ô MOVE 3TO SAVE & EXIT
X-SERIESTMUSER MANUAL
23
TECH SUPPORT COMMENT: In
LLOOWW LLIIGGHHTT MMOODDEE sseettttiinngg,
,
the camera can be programmed to auto switch to
IR ‘ON’ MONO by using... THE IRIS KEY or A PRESET NUMBER.
8.2 LOW LIGHT MODE SETTINGS
The following settings apply when the camera switches from
DDAAYY MMOODDEE SSEETTTTIINNGGS
S
(colour) to
NNIIGGHHTT MMOODDEE>>LLOOWW LLIIGGHHTT
MMOODDEE SSEETTTTIINNGGS
S
8.2.1 COLOUR/MONO Select either
CCOOLLOOUURR oorr MMOONNO
O
for when the camera switches to
LLOOWW LLIIGGHHTT MMOODDEE SSEETTTTIINNGG.
.
In this mode, on DAY to NIGHT
change over, the camera will be ‘forced’ to stay in colour or mono (without IR) regardless of ambient light conditions.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > NIGHT SETTINGS > COLOUR/MONO Ô MOVE 56 TO SELECT COLOUR OR MONO Ô MOVE 3TO SAVE & EXIT
8.2.2 SHUTTER SPEED The shutter speed can be slowed down to increase light sensitivity. Default setting = 1/25.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > SHUTTER SPEED Ô MOVE 56 TO CHANGE SHUTTER SPEED Ô MOVE 3TO SAVE & EXIT
8.2.3 EXPOSURE COMPENSATION Adjustment for unusual lighting distribution. Compensation can be either positive (additional exposure) or negative (reduced exposure). Default setting = 0.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > EXPOSURE COMPENSATION Ô MOVE 56 TO ADJUST EXPOSURE LEVEL BETWEEN +7 AND -7 Ô MOVE 3TO SAVE & EXIT
8.2.4 JOYSTICK FOCUS MODE There are two settings AUTO focus & MANUAL focus. Default setting for NIGHT is AUTO.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > JOYSTICK FOCUS MODE Ô MOVE 56 TO SELECT AUTO OR MANUAL Ô MOVE 3TO SAVE & EXIT
8.2.5 PRESET FOCUS MODE
((SSOONNYY MMOODDUULLEE)
)
There are two modes: AUTO & STORED. Default setting for NIGHT
is STORED.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > PRESET FOCUS MODE Ô MOVE 56 TO SELECT AUTO OR STORED Ô MOVE 3TO SAVE & EXIT
8.2.6 ADVANCED CONFIGURATION
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > ADVANCED CONFIGURATION
8.2.6.1 ZOOM LIMIT
((SSOONNYY MMOODDUULLEE)
)
This can be adjusted from 10 to 100%
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > ADV CONFIG > ZOOM LIMIT Ô MOVE 56 TO ADJUST ZOOM LIMIT BETWEEN 10% and 100% Ô MOVE 3TO SAVE & EXIT
X-SERIESTMUSER MANUAL
24
8.2.6.2 BACKLIGHT COMPENSATION The ability of a Camera to compensate in cases where a subject with a large amount of background light would otherwise be obscured by blooming or silhouetting.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > ADV CONFIG > BACKLIGHT COMPENSATION Ô MOVE 56 TO SELECT ON/OFF Ô MOVE 3 TO SAVE & EXIT
8.2.6.3 IMAGE STABILISER
((SSOONNYY MMOODDUULLEE)
)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > ADV CONFIG > IMAGE STABILISER Ô MOVE 56 TO SELECT ON/OFF Ô MOVE 3 TO SAVE & EXIT
8.2.6.4 WHITE BALANCE
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > ADV CONFIG >
WWHHIITTEE BBAALLAANNCCE
E
Ô MOVE 56 TO SELECT OUTDOOR AUTO/ATW/OUTDOOR/INDOOR/AUTO/SODIUM LAMP/SODIUM LAMP AUTO Ô MOVE 3 TO SAVE & EXIT
8.2.6.5 WIDE DYNAMIC RANGE
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > ADV CONFIG >
WWIIDDEE DDYYNNAAMMIICC RRAANNGGE
E
Ô MOVE 56 TO SELECT OFF/AUTO/ON Ô MOVE 3 TO SAVE & EXIT
8.2.6.6 NOISE REDUCTION (PARKED)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > ADV CONFIG >
NNOOIISSEE RREEDDUUCCTTIIOONN ((PPAARRKKEEDD)
)
Ô MOVE 56 TO ADJUST 0 to 5 (2 IS DEFAULT) Ô MOVE 3 TO SAVE & EXIT
8.2.6.7 NOISE REDUCTION (MOVING)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > ADV CONFIG >
NNOOIISSEE RREEDDUUCCTTIIOONN ((MMOOVVIINNGG)
)
Ô MOVE 56 TO ADJUST 0 to 5 (0 IS DEFAULT) Ô MOVE 3 TO SAVE & EXIT
8.2.6.8 SPOT AE
((SSOONNYY MMOODDUULLEE)
)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > ADV CONFIG >
SSPPOOTT AAE
E
Ô MOVE 56 TO SELECT OFF/ON (ON IS DEFAULT) Ô MOVE 3 TO SAVE & EXIT
8.2.6.9 APERTURE CORRECTION
((SSOONNYY MMOODDUULLEE)
)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > ADV CONFIG >
AAPPEERRTTUURREE CCOORRRREECCTTIIOON
N
Ô MOVE 56 TO SELECT 1 to 16 (9 IS DEFAULT) Ô MOVE 3 TO SAVE & EXIT
8.2.6.10 GAIN LIMIT
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > LOW LIGHT MODE SETTINGS > ADV CONFIG >
GGAAIINN LLIIMMIIT
T
Ô MOVE 56 TO CHANGE VALUE Ô MOVE 3TO SAVE & EXIT
X-SERIESTMUSER MANUAL
25
8.3 IR MODE SETTINGS
8.3.1 FOCUS CORRECTION
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > FOCUS CORRECTION Ô MOVE 56 TO SELECT ON OR OFF(DEFAULT) Ô MOVE 3TO SAVE & EXIT
8.3.2 SHUTTER SPEED The shutter speed can be slowed down to increase light sensitivity. Default setting = 1/25.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > SHUTTER SPEED Ô MOVE 56 TO CHANGE SHUTTER SPEED 1/12 to AUTO Ô MOVE 3TO SAVE & EXIT
8.3.3 EXPOSURE COMPENSATION Adjustment for unusual lighting distribution. Compensation can be either positive (additional exposure) or negative (reduced exposure). Default setting = 0.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > EXPOSURE COMPENSATION Ô MOVE 56 TO ADJUST EXPOSURE LEVEL BETWEEN +7 AND -7 Ô MOVE 3TO SAVE & EXIT
8.3.4 JOYSTICK FOCUS MODE There are two settings AUTO focus & MANUAL focus. Default setting for NIGHT is AUTO.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > JOYSTICK FOCUS MODE Ô MOVE 56 TO SELECT AUTO OR MANUAL Ô MOVE 3TO SAVE & EXIT
8.3.5 PRESET FOCUS MODE
((SSOONNYY MMOODDUULLEE)
)
There are two modes: AUTO & STORED. Default setting for NIGHT is STORED.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > PRESET FOCUS MODE Ô MOVE 56 TO SELECT AUTO OR STORED Ô MOVE 3TO SAVE & EXIT
8.3.6 ADVANCED CONFIGURATION
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > ADVANCED CONFIGURATION
8.3.6.1 ZOOM LIMIT
((SSOONNYY MMOODDUULLEE)
)
This can be adjusted from 10 to 100%
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > ADV CONFIG > ZOOM LIMIT Ô MOVE 56 TO ADJUST ZOOM LIMIT BETWEEN 10% and 100% Ô MOVE 3TO SAVE & EXIT
8.3.6.2 BACKLIGHT COMPENSATION The ability of a Camera to compensate in cases where a subject with a large amount of background light would otherwise be obscured by blooming or silhouetting.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > ADV CONFIG > BACKLIGHT COMPENSATION Ô MOVE 56 TO SELECT ON/OFF Ô MOVE 3 TO SAVE & EXIT
TECH SUPPORT COMMENT: For typical CCTV applications it is recommended to leave the setting to default ‘OFF’.
X-SERIESTMUSER MANUAL
26
8.3.6.3 IMAGE STABILISER
((SSOONNYY MMOODDUULLEE)
)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > ADV CONFIG > IMAGE STABILISER Ô MOVE 56 TO SELECT ON/OFF Ô MOVE 3 TO SAVE & EXIT
8.3.6.4 WHITE BALANCE
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > ADV CONFIG >
WWHHIITTEE BBAALLAANNCCE
E
Ô MOVE 56 TO SELECT OUTDOOR AUTO/ATW/OUTDOOR/INDOOR/AUTO/SODIUM LAMP/SODIUM LAMP AUTO Ô MOVE 3 TO SAVE & EXIT
8.3.6.5 WIDE DYNAMIC RANGE
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > ADV CONFIG >
WWIIDDEE DDYYNNAAMMIICC RRAANNGGE
E
Ô MOVE 56 TO SELECT OFF/AUTO/ON Ô MOVE 3 TO SAVE & EXIT
8.3.6.6 NOISE REDUCTION (PARKED)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > ADV CONFIG >
NNOOIISSEE RREEDDUUCCTTIIOONN ((PPAARRKKEEDD)
)
Ô MOVE 56 TO ADJUST 0 to 5 (0 IS DEFAULT) Ô MOVE 3 TO SAVE & EXIT
8.3.6.7 NOISE REDUCTION (MOVING)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > ADV CONFIG >
NNOOIISSEE RREEDDUUCCTTIIOONN ((MMOOVVIINNGG)
)
Ô MOVE 56 TO ADJUST 0 to 5 (2 IS DEFAULT) Ô MOVE 3 TO SAVE & EXIT
8.3.6.8 SPOT AE
((SSOONNYY MMOODDUULLEE)
)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > ADV CONFIG >
SSPPOOTT AAE
E
Ô MOVE 56 TO SELECT OFF/ON (ON IS DEFAULT) Ô MOVE 3 TO SAVE & EXIT
8.3.6.9 APERTURE CORRECTION
((SSOONNYY MMOODDUULLEE)
)
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > ADV CONFIG >
AAPPEERRTTUURREE CCOORRRREECCTTIIOON
N
Ô MOVE 56 TO SELECT 1 to 16 (9 IS DEFAULT) Ô MOVE 3 TO SAVE & EXIT
8.3.6.10 GAIN LIMIT
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IR MODE SETTINGS > ADV CONFIG >
GGAAIINN LLIIMMIIT
T
Ô MOVE 56 TO CHANGE VALUE Ô MOVE 3TO SAVE & EXIT
8.4 VIDEO GAIN
Video gain can be set from 0 to 7db to compensate for losses in long cable runs. Default setting is 2.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > VIDEO GAIN Ô MOVE 56TO ADJUST from 0 - 7 Ô MOVE 3 TO SAVE & EXIT
TECH SUPPORT COMMENT: It is recommended to use video lift first before adding gain as this will
usually give better results
8.5 VIDEO LIFT
High frequency video lift can be set between 0 & 8. Default is zero.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > VIDEO LIFT Ô MOVE 56 TO ADJUST BETWEEN 0 -8 Ô MOVE 3TO SAVE & EXIT
8.6 IRIS KEY USAGE
The iris key can be assigned to either:
Adjust exposure compensation - brighten/darken image.
Shutter speed - allows integration & can only be adjusted when the camera is in NIGHT mode.
Night Mode Switching – switches between IR mode & Night Mode (Low Light Setting).
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > IRIS KEY USAGE Ô MOVE 56 TO SELECT EXPOSURE COMPENSATION, SHUTTER SPEED, NIGHT MODE SWITCHING OR OFF Ô MOVE 3TO SAVE & EXIT
8.7 DIGITAL ZOOM
Select digital zoom if user wants zoom beyond optical zoom limit. Default is off.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > DIGITAL ZOOM Ô MOVE 56 SELECT YES/NO Ô MOVE 3TO SAVE & EXIT
8.8 INVERT CAMERA IMAGE
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > INVERT CAMERA IMAGE Ô MOVE 56 SELECT YES/NO Ô MOVE 3TO SAVE & EXIT
8.9 MIRROR CAMERA IMAGE
This function reverses the image e.g. left to right will appear right to left.
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > MIRROR CAMERA IMAGE Ô MOVE 56 SELECT YES/NO Ô MOVE 3TO SAVE & EXIT
8.10 CROSS
HAIR
Ô LOGIN > MAIN MENU > CAMERA SETTINGS > CROSS HAIR Ô MOVE 56 SELECT ON/OFF Ô MOVE 3TO SAVE & EXIT
X-SERIESTMUSER MANUAL
27
TECH SUPPORT COMMENT: Picture degradation may occur at high zoom
TECH SUPPORT COMMENT: Technicians should set the Camera orientation first see 6.4.7.
‘INVERT CAMERA IMAGE’ function should only be used to correct for special cases once orientation has been set otherwise it should be set to NO.
TECH SUPPORT COMMENT: Technician should attempt to compensate for poor cable runs using video lift,
before using video gain
9 JOYSTICK & WIPER
9.1 JOYSTICK CURVE
There are three settings. The following options describe how sensitive the joystick is to small movements. Linear is most sensitive, quasi linear and non-linear allow for finer control at low speeds, ramping up with larger movements. Quasi linear is the default.
Ô LOGIN > MAIN MENU > JOYSTICK > JOYSTICK CURVE Ô MOVE 56 TO SELECT QUASI LINEAR, LINEAR OR NON-LINEAR Ô MOVE 3TO SAVE & EXIT
9.2
ZOOM RATIO
The zoom ratio affects how much the Camera slows down as you zoom in [the higher the numbers make the speed drop off more as you zoom in]. The default setting is 16.
Ô LOGIN > MAIN MENU > JOYSTICK > ZOOM RATIO Ô MOVE 56 8,16,32,64 Ô MOVE 3TO SAVE & EXIT
9.3 JOYSTICK SPEED
Default setting is 60%. Use 56 to increase/decrease.
Ô LOGIN > MAIN MENU > JOYSTICK > JOYSTICK SPEED Ô MOVE 56 INCREASE/DECREASE SPEED SETTING Ô MOVE 3TO SAVE & EXIT
9.4 WIPER
Applies to RVX models fitted with wiper.
Ô LOGIN > MAIN MENU > JOYSTICK > WIPER Ô MOVE 56 INTERMITTENT WIPE (1-99) OR WIPER TIMEOUT (1-255) Ô MOVE 56 TO CHANGE TIME IN SECONDS: WIPE (1-99) TIMEOUT (1-255) Ô MOVE 3TO SAVE & EXIT
9.4.1 INTERMITTENT WIPE
Ô LOGIN > MAIN MENU > JOYSTICK > WIPER > INTERMITTENT WIPE Ô WIPER SHORT-CUT PRESET > TO SELECT 1–99 SECS
9.4.2 WIPER TIMEOUT
Ô LOGIN > MAIN MENU > JOYSTICK > WIPER > WIPER TIMEOUT Ô WIPER SHORT-CUT PRESET > TO SELECT 1–255 MINS
9.4.3 WIPER SHORT-CUT PRESET If the control unit does not have a dedicated wiper key function it is possible to allocate a ‘PRESET’ number to activate/deactivate the wiper.
Ô LOGIN > MAIN MENU > JOYSTICK > WIPER > WIPER SHORTCUT PRESET Ô WIPER SHORT-CUT PRESET > SELECT NO PRESET/OR PRESET NUMBER BETWEEN 1-100
To activate wiper: Press preset number To deactivate wiper: Select same preset number
9.4.4 WASH SHORTCUT PRESET If the control unit does not have a dedicated wiper key function it is possible to allocate a ‘PRESET’ number to activate/deactivate the wiper.
Ô LOGIN > MAIN MENU > JOYSTICK > JOYSTICK WIPER Ô WASH SHORT-CUT PRESET > SELECT NO PRESET/OR PRESET NUMBER BETWEEN 1-100
X-SERIESTMUSER MANUAL
28
X-SERIESTMUSER MANUAL
29
9.5 PAN LIMITS
Program Camera to pan only within pre-defined left and right limits. This can be useful if the Camera is mounted on the corner of a building or a wall. If presets are programmed the Camera will stay within the permitted limits, and not take the shortest route .
Ô LOGIN > MAIN MENU > JOYSTICK > PAN LIMIT > SET PAN LIMITS Ô MOVE 56 TO SELECT ON/OFF Ô MOVE 3TO SAVE & EXIT
9.5.1 SET RIGHT LIMIT
Ô LOGIN > MAIN MENU > JOYSTICK > PAN LIMIT > SET RIGHT PAN LIMIT Ô PAN THE CAMERA TO THE RIGHT MOST PAN LIMIT Ô PRESS SELECT OR WAIT 10 SECS FOR AUTO SET Ô MOVE 3TO SAVE & EXIT
9.5.2 SET LEFT LIMIT
Ô LOGIN > MAIN MENU > JOYSTICK > PAN LIMIT > SET LEFT PAN LIMIT Ô PAN THE CAMERA TO THE LEFT MOST PAN LIMIT Ô PRESS SELECT OR WAIT 10 SECS FOR AUTO SET Ô MOVE 3TO SAVE & EXIT
9.6 SET TILT LIMITS
Default setting is ‘on’. Limits are determined by the Camera Orientation set-up see 6.4.7
All X-Series Cameras have the following viewing ‘tilt’ angle:
In Dome configuration (i.e. with lid): 90
º to 10º above horizon.
In Ball configuration (i.e. without lid): 90º to 60º above horizon.
Default tilt setting is ‘ON’. Limits are determined by the Camera orientation setup. See 6.4.7
Ô LOGIN > MAIN MENU > JOYSTICK > TILT LIMIT > SET TILT Ô MOVE 56 TO SELECT ON/OFF Ô MOVE 3TO SAVE & EXIT
9.7 SHORT-CUTS
It is possible to allocate a PRESET number to activate the WIPER, WASH or NIGHT MODE SWITCHING.
Ô LOGIN > MAIN MENU > JOYSTICK > SHORTCUTS Ô MOVE 56 TO SELECT WIPER/WASH/NIGHTMODE SWITCHING Ô MOVE 56 SELECT ‘NO PRESET’ OR ‘PRESET NUMBER’ BETWEEN 1 - 100 Ô MOVE 3TO SAVE & EXIT
9.8 AUXILLARY RELAY FUNCTION
If using an RVX-PSU-ALM16 or RVX-PSU-AALM16-W, the auxilliary relay can be programmed to transmit ‘active’ alarms only or trigger when the camera switches to IR NIGHT MODE (e.g. Switch on additional IR or WHITE LIGHTING etc.).
Ô LOGIN > MAIN MENU > JOYSTICK > AUX RELAY FUN Ô MOVE 56 TO SELECT OFF/ACTIVE ALARMS/ NIGHT MODE Ô MOVE 3TO SAVE & EXIT
TECH SUPPORT COMMENT: If re-setting LEFT & RIGHT PAN limits the technician should turn ‘use limits’
off to allow full movement
TECH SUPPORT COMMENT: If a preset number is allocated to the wiper or IR lamp function, it cannot be used
for a preset position. The wiper or IR function will over-ride a preset position if it shares the same preset number.
9.9 COMPATIBILITY MODE
Use this function if ADPRO/TELEPRECISION ABSOLUTE POSITIONING/BBV1000/1500 Control Systems are being deployed. All other systems select ‘STANDARD’.
Ô LOGIN > MAIN MENU > JOYSTICK > COM MODE Ô MOVE 56 TO SELECT CONTROL SYSTEM/STD OR OFF Ô MOVE 3TO SAVE & EXIT
10 PRESETS & TOURS
Presets and tours can be programmed using third party keyboard controllers, or from the Camera’s own internal menu. To access presets & tours menu:
Ô LOGIN > MAIN MENU > PRESETS & TOURS
10.1 FOCUS SHIFT
10.2 PRESET
10.2.1 SET A PRESET (USING CAMERA INTERNAL MENU)
Ô LOGIN > MAIN MENU > PRESETS & TOURS > PRESETS > SET PRESETS Ô MOVE 56 TO SELECT PRESET NUMBER TO BE SAVED (1 - 100) Ô NUDGE JOYSTICK/ARROW right TO PRODUCE COSSHAIR Ô USE PTZ CONTROL TO MOVE CAMERA INTO POSITION Ô USE ENTER OR CANCEL TO QUIT OR WAIT 10 SECS FOR PRESET TO AUTO SET Ô REPEAT STEPS 4 TO 6 TO SET MORE PRESETS Ô MOVE 3TO SAVE & EXIT
10.2.2 EDIT PRESET The default display title for a preset is p1, p2, p3 etc. TO CUSTOMISE preset titles. A preset can be edited in three ways: TITLE, NIGHT MODE SWITCHING & CLEAR PRESET
10.2.2.1 TITLE - The default preset title ‘p1’,’p2’ etc can be renamed e.g. front door:
Ô LOGIN > MAIN MENU > PRESETS & TOURS > PRESETS > EDIT PRESETS Ô MOVE 56 TO SELECT PRESET NUMBER TO BE EDITED Ô USE4 TO INPUT TITLE Ô USE 56 TO SELECT ALPHANUMERIC CHARACTERS Ô MOVE 3TO SAVE & EXIT
10.2.2.2 NIGHT MODE SWITCHING A preset can be programmed to switch to a different night mode setting e.g infra red, low light colour or mono with no infrared. for example, this may be useful if the camera is set to switch to low light colour mode at night, but needs to automatically switch to ir mono in certain preset position
Ô LOGIN > MAIN MENU > PRESETS & TOURS > PRESETS > EDIT PRESETS Ô MOVE 56 TO SELECT NIGHT MODE Ô MOVE 56 TO SELECT IR MODE/LOW LIGHT MODE/AUTO Ô MOVE 3TO SAVE & EXIT
NOTE: Auto will default to the setting selected in ‘SELECT NIGHT MODE’ 7.1
X-SERIESTMUSER MANUAL
30
TECH SUPPORT COMMENT: Technicians will be familiar with setting up focus on a ‘fixed’ camera by
temporarily fitting the lens with a Neutral Density (ND) filter to compensate for focus shift when the camera switches to mono. The best way to ensure optimum focus on THE REDVISION X-SERIES PTZ/Dome camera is to set ‘night-time’ presets when the light levels are low and the camera is in mono. If using a PTZ fitted with IR, the IR pods should be switched ON (RVX-IR versions only). The controller’s ‘focus near’ focus far can be used to fine tune the focus manually before saving the preset. This way the camera will remember the IR focus settings at an absolute focal length for that specific preset.
X-SERIESTMUSER MANUAL
31
10.2.2.3 CLEAR PRESET – (DELETES INDIVIDUAL PRESET & CONTENT)
Ô LOGIN > MAIN MENU > PRESETS & TOURS > PRESETS > EDIT PRESETS Ô MOVE 56 TO SELECT PRESET NUMBER TO BE EDITED
USE
4 TO SELECT PRESET
USE
56 TO SELECT YES/NO
Ô MOVE 3TO SAVE & EXIT
10.2.3 PRESET SPEED The speed at which the Camera moves to each preset can be programmed. Default is 60%. To change the value:
Ô LOGIN > MAIN MENU > PRESETS & TOURS > PRESETS > PRESET SPEED Ô MOVE 56 TO SELECT PRESET Ô MOVE 56 TO CHANGE VALUE (10% TO 100%) Ô MOVE 3TO SAVE & EXIT
10.3
TOURS
Tour 1 by default is fully populated & includes all set presets. It is possible to program up to 100 presets per tour. Once a tour is set the Camera moves between each preset within that tour automatically, and will dwell [10.3.1.4] for a period specified. The restore tour mode [10.4.4] can be activated on any tour from 1 to 8. The tour is continually repeated unless interrupted by:
Manual pan, tilt or zoom
Calling up a preset position
An alarm activation
10.3.1
TOUR 1 TO 8 The user can set up to 8 different tours. Tour 1 by default is fully populated & includes all set presets. These can be edited if required. All other tours are empty.
Ô LOGIN > MAIN MENU > PRESETS & TOURS > TOURS Ô TOUR Ô MOVE 56 TO SELECT A TOUR NUMBER 1 - 8 Ô MOVE 56 TO CHANGE VALUE Ô MOVE 3TO SAVE & EXIT
10.3.1.1 TOUR TITLE (HOW TO PROGRAM) Each tour can be assigned its own title. The default title is T1, T2, T3 etc.
Ô LOGIN > MAIN MENU > PRESETS & TOURS > TOURS > TOUR TITLES TOUR Ô MOVE 4 TO INPUT TITLE Ô MOVE 56 TO SELECT A TOUR NUMBER TO BE NAMED Ô MOVE 56 TO SELECT ALPHANUMERIC CHARACTERS Ô MOVE 3TO SAVE & EXIT
10.3.1.2 HOW TO INITIALISE A TOUR
Ô LOGIN > MAIN MENU > PRESETS & TOURS > TOURS > INITIALISE TOUR Ô MOVE 56 TO SELECT EITHER CANCEL (DOES NOTHING & LEAVES TOUR INTACT), CLEAR (REMOVES
PRESETS FROM TOUR) OR SET (POPULATES THE TOUR WITH ALL SET PRESETS IN ORDER)
Ô MOVE 3TO SAVE & EXIT
10.3.1.3 EDIT TOUR Allows operator to edit the standard tour sequence e.g. preset 1,2,3, The default setting is position 1 of the tour = preset 1, and, position 2 = preset 2 etc. The tour can be edited so that position 1 could = preset 2 for example. any positions set to ‘NO preset’ will be ignored when the tour is running.
Ô LOGIN > MAIN MENU > PRESETS & TOURS > TOURS > EDIT TOUR Ô MOVE 56 TO SELECT TOUR TO BE EDITED Ô MOVE 3TO SAVE & EXIT
TECH SUPPORT COMMENT: Note that any positions set to empty presets will be skipped
10.3.1.4 TOUR DWELL TIME The time the Camera dwells between each preset can be programmed between 1 & 120 seconds. Default is 8 seconds.
Ô LOGIN > MAIN MENU > PRESETS & TOURS > TOURS > DWELL Ô MOVE 56 TO SELECT DWELL TIME IN SECONDS Ô MOVE 3TO SAVE & EXIT
10.3.1.5 SPEED The speed at which the Camera moves to each preset. Programmed in seconds.
Ô LOGIN > MAIN MENU > PRESETS & TOURS > TOURS > SPEED Ô MOVE 56 TO SELECT SPEED IN SECONDS Ô MOVE 3TO SAVE & EXIT
10.3.1.6 TOUR ORDER The speed at which the Camera moves to each preset. Programmed in seconds.
Ô LOGIN > MAIN MENU > PRESETS & TOURS > TOURS > TOUR ORDER Ô MOVE 56 TO SELECT STANDARD (1,2,3)/PING-PONG (1,2,3,- 3,2,1) /RANDOM Ô MOVE 3TO SAVE & EXIT
10.3.1.7 FREEZE FRAME DURING SEEK Freezes the last preset image until Camera moves to next preset image.
Ô LOGIN > MAIN MENU > PRESETS & TOURS > TOURS > FREEZE FRAME Ô MOVE 56 TO SELECT FREEZE FRAME Ô MOVE 3TO SAVE & EXIT
10.4 RESTORE (PRESETS & TOURS)
10.4.1 RESTORE TO NUMBER - EITHER TOUR NUMBER OR PRESET NUMBER
Ô LOGIN > MAIN MENU > PRESETS & TOURS > RESTORE > RESTORE TO NUMBER Ô MOVE 56 TO SELECT NUMBER
(1 TO 100 IF ASSIGNING PRESET NUMBER) (1 TO 8 IF ASSIGNING TOUR NUMBER)
Ô MOVE 3TO SAVE & EXIT
10.4.2 TIMED RESTORE WEEKDAY
Ô LOGIN > MAIN MENU > PRESETS & TOURS > RESTORE > TIMED RESTORE WEEKDAY Ô MOVE 34 TO SELECT HOUR TIME BLOCKS* Ô MOVE 56 TO SELECT ENABLE (1 - 9) DISABLE (-) Ô MOVE 3TO SAVE & EXIT
*Note: This is a global setting for Monday through Friday.
10.4.3 TIMED RESTORE WEEKEND
Ô LOGIN > MAIN MENU > PRESETS & TOURS > RESTORE > TIMED RESTORE WEEKEND Ô MOVE 34 TO SELECT HOUR TIME BLOCKS* Ô MOVE 56 TO SELECT ENABLE (1 - 9) DISABLE (-) Ô MOVE 3TO SAVE & EXIT
*Note: This is a global setting for Saturday & Sunday.
X-SERIESTMUSER MANUAL
32
X-SERIESTMUSER MANUAL
33
10.4.4 RESTORE MODE (PRESETS & TOURS) Use this option to make the Camera revert to a tour or preset after a specified delay period (in seconds) of inactivity (see RESTORE DELAY 10.4.5). Restore modes:
Ô LOGIN > MAIN MENU > PRESETS & TOURS > RESTORE > RESTORE MODE Ô MOVE 56 TO SELECT: OFF, FIXED TOUR, FIXED PRESET, TIMED TOUR, TIMED PRESET Ô MOVE 3TO SAVE & EXIT
10.4.5 RESTORE DELAY (PRESETS & TOURS) Time taken before presets or tours are restored. Select between 5 - 180 seconds and OFF.
Ô LOGIN > MAIN MENU > PRESETS & TOURS > RESTORE DELAY Ô MOVE 56 TO SELECT ‘OFF’or CHANGE VALUE IN SECONDS (5 - 180) Ô MOVE 3TO SAVE & EXIT
11 PRIVACY ZONES
Multiple privacy zones can be programmed.
11.1 SET/CLEAR MASK
Ô LOGIN > MAIN MENU > PRIVACY > SET/CLEAR MASK Ô MOVE 56 TO SELECT A MASK NUMBER Ô MOVE 4 TO REVEAL CROSS HAIRS Ô MOVE CAMERA TO REQUIRED VIEW USING PTZ CONTROLS Ô SELECT ENTER COMMAND FROM CONTROL OR WAIT 15 SECS UNTIL RED PATCH APPEARS Ô MOVE 56 TO SCROLL TO NEXT MASK NUMBER Ô REPEAT STEPS 3 TO 5 TO CREATE NEW PRIVACY MASKS Ô MOVE 3TO SAVE & EXIT
11.2 ZOOM THRESHOLD
Ô LOGIN > MAIN MENU > PRIVACY > ZOOM THRESHOLD Ô MOVE 56 0 - 100% Ô MOVE 3TO SAVE & EXIT
11.3 EDIT MASK
Ô LOGIN > MAIN MENU > PRIVACY > EDIT MASK Ô MOVE 56 TO SELECT A MASK NUMBER TO BE EDITED Ô CLEAR MASK 56 YES/NO Ô MOVE 3TO SAVE & EXIT
TECH SUPPORT COMMENT: Recommended privacy patch should be set 50% larger than object being masked
TECH SUPPORT COMMENT: Can also use ‘timed restore weekday/weekend’ to restore.
To restore to a different tour at different times see 12.4
X-SERIESTMUSER MANUAL
34
12 ALARM HANDLING IN MENU SOFTWARE
The alarms can be mapped to any preset or tour, or to just put a message on the screen.
Within the Alarm Edit menu (12.4) use
56 to select alarm number; within each alarm you can set type of action, dwell,
and time-based masking for weekdays (12.4.1) & weekends (12.4.2).
The time-based masking is SECONDARY to the "Enable alarms" menu (12.1). If the alarm is not enabled, it will be completely ignored.
If an alarm is enabled, but masked, the user can then decide to set it to be "silent" or "message only" [12.4.3].
Title [12.4.6] is the title or name of the alarm (just like giving a preset or tour a title), this will be displayed on screen when the alarm activates.
ALARM ACTIONS:
"Go to preset" will go to preset *if set* and dwell on it for <dwell> seconds. Otherwise it will just display alarm title (if set) or alarm number (if not) on screen for <dwell> before moving on.
"Go to tour" will invoke the selected tour (if set) for <dwell> seconds. Otherwise it will just display alarm title (if set) alarm number (if not) on screen for <dwell> before moving on.
It is down to the user to ensure that the alarm dwell time gives sufficient time to run the tour, or as much of the tour as they require.
"Message only" will display alarm title (if set) / number (if not) on screen for <dwell> seconds before moving on.
Silent will do nothing and move on instantly.
When all alarms are cleared (12.4.9), the Camera will be pointing at wherever the last preset was, or running the last tour. This will continue until either the user moves the Camera, or the RESTORE MODE (10.4.4)[if set] kicks in.
12.1 ENABLE /DISABLE ALARMS
Alarms need to be ‘enabled’ in order to function correctly. This feature can also be used to disable nuisance alarms caused by faulty alarm input devices such as PIRs. The alarm default setting is ‘all’ alarms enabled [block].
Ô LOGIN > MAIN MENU > ALARMS>ENABLE ALARMS Ô MOVE 34 TO SELECT ALARM NUMBER 1 TO 16 Ô MOVE 56 TO ENABLE(BLOCK) /DISABLE (CLEAR) Ô MOVE 3TO SAVE & EXIT
12.2 ALARM OVER-RIDE
On alarm activation the Camera automatically switches to the preset view of the most current alarm. The alarm overide is the time the Camera will wait before over-riding the operator’s joystick commands and moving to alarm action. The over­ride time can be set to between 1 and 20 seconds. Default is 10 seconds.
Ô LOGIN > MAIN MENU > ALARMS > ALARM OVERIDE TIME Ô MOVE 56 TO CHANGE VALUE 1 -20 SECS Ô MOVE 3TO SAVE & EXIT
12.3 ALARM CYCLE TIME
The alarm cycle time programmed in seconds is the time it takes to tour the presets of still active alarms. Default is 3 seconds. This function will be ignored if alarms are connected directly to third party control equipment rather than the Redvision Alarm Module (RV-PSU-ALM16) & (RV-PSU-ALM16-W)
Ô LOGIN > MAIN MENU > ALARMS > NEW ALARM CYCLE TIME Ô MOVE 56 TO CHANGE VALUE 1 -20 SECS Ô MOVE 3TO SAVE & EXIT
X-SERIESTMUSER MANUAL
35
12.4 EDIT ALARMS
Use this menu to program how alarms are configured e.g. Create a weekday time schedule when alarms are automatically enabled or disabled and the type of action required when an alarm is enabled & subsequently activated etc. Alarm dwell (12.4.7) time can also be programmed in the menu.
Ô LOGIN > MAIN MENU > ALARMS > EDIT ALARMS > 1-16 >
12.4.1
ACTIVE TIME WEEKDAYS
Ô LOGIN > MAIN MENU > ALARMS > EDIT ALARMS > 1-16 > ACTIVE TIME WEEKDAYS Ô MOVE 34 TO SELECT HOUR TIME BLOCKS* Ô MOVE 56 TO SELECT ENABLE(SOLID) DISABLE (CLEAR) Ô MOVE 3TO SAVE & EXIT
*Note: This is a global setting for monday through friday.
12.4.2 ACTIVE TIME WEEKENDS
Ô LOGIN > MAIN MENU > ALARMS > EDIT ALARMS > 1-16 > ACTIVE TIME WEEKEND Ô MOVE 34 TO SELECT HOUR TIME BLOCKS* Ô MOVE 56 TO SELECT ENABLE(SOLID) DISABLE (CLEAR) Ô MOVE 3TO SAVE & EXIT
*Note: This is a global setting for saturday and sunday.
12.4.3 ACTION WHEN ACTIVE
Ô LOGIN > MAIN MENU > ALARMS > EDIT ALARMS > 1-16 > ACTION WHEN ACTIVE Ô MOVE 56 TO SELECT ‘GO TO PRESET’, MESSAGE ONLY, SILENT OR RUN TOUR Ô MOVE 3TO SAVE & EXIT
12.4.4 ACTION NUMBER
Ô LOGIN > MAIN MENU > ALARMS > EDIT ALARMS > 1-16 > ACTION NUMBER Ô MOVE 56 TO SELECT NUMBER BETWEEN 1- 100 Ô MOVE 3TO SAVE & EXIT
12.4.5 ACTION WHEN MASKED
Ô LOGIN > MAIN MENU > ALARMS > EDIT ALARMS > 1-16 > ACTION WHEN MASKED Ô MOVE 56 TO SELECT ‘GOTO MESSAGE ONLY OR SILENT Ô MOVE 3TO SAVE & EXIT
12.4.6 TITLE
Ô LOGIN > MAIN MENU > ALARMS > EDIT ALARMS > 1-16 > TITLE Ô MOVE 56 TO SELECT ALPHNUMERIC CHARACTERS Ô MOVE 3TO SAVE & EXIT
TECH SUPPORT COMMENT: The ‘Action Number’ is the number of the preset or tour to go depending on
which option is selected
X-SERIESTMUSER MANUAL
36
12.4.7 NEW ALARM DWELL The Camera will move to a corresponding preset when a new alarm occurs.
On multiple alarms, presets will be called up in sequence. the dwell time (in seconds) between each alarm can be programmed. Default is 5 seconds. This function will be ignored if alarms are connected directly to third party control equipment rather than the Redvision alarm module.
Ô LOGIN > MAIN MENU > ALARMS > EDIT ALARMS > 1-16 > NEW ALARM DWELL TIME Ô MOVE 56 TO CHANGE VALUE BETWEEN 1 – 20 SECONDS Ô MOVE 3TO SAVE & EXIT
12.4.8 SHOW ALARM INFO
Ô LOGIN > MAIN MENU > ALARMS > EDIT ALARMS > 1-16 > SHOW ALARM INFO Ô ALARM INFO INCLUDES: ALARM NUMBER, ’ENABLED Y/N, ACTIVE Y/N, MASKED Y/N, ACTION WHEN ACTIVE,
LAST ACTIVATION
Ô MOVE 3TO SAVE & EXIT
12.4.9 CLEAR COUNTERS
Ô LOGIN > MAIN MENU > ALARMS > EDIT ALARMS > 1-16 > CLEAR COUNTERS Ô MOVE 56 TO SELECT YES OR NO Ô MOVE 3TO SAVE & EXIT
TECH SUPPORT COMMENT: See ALARM OVER-RIDE 12.2 and ALARM CYCLE TIME 12.3 - the new alarm
dwell defines how long the Camera will stay on a new alarm when cycling through the active alarms list.
TECH SUPPORT COMMENT: ALSO INCLUDES NUMBER OF ACTIVATIONS WHICH COULD BE USEFUL FOR
TRACKING DOWN ‘CHATTERING’ ALARMS
IImmaaggee sseennssoor
r
Sony EXview 1/4” HAD CCD (PS) RS485 Pelco P, Pelco D, Vista, Dennard &
Bosch
MMooddeell
FCB-EX490E/P FCB-EX985 E/P FCB-EX1020/P Coax BBV
OOppttiiccaall zzoooomm
RVX18x Optical RVX28x Optical RVX36x Optical Addressing DIP switch
DDiiggiittaall zzoooom
m
12x 12x 12x Baud rate 2400,4800.9600 & 19200
HHoorriizzoonnttaall rreessoolluuttiioon
n
550TVL 550TVL 550TVL
AAnnggllee ooff vviieew
w
2.8 - 48° 2.2° – 54.2° 1.7° – 57.8°
FFooccaall LLeennggtth
h
4.1 to 73.8mm 3.5 – 91.0mm 3.5 – 91.0mm
(F1.4 to F3)
(F1.6 to F3.8) (F1.6 to F3.8)
LLeefftt && RRiigghhtt PPaann LLiimmiitts
s
Programmable
MMiinn iilllluummiinnaattiioon
n
0.7 1x (F1.4,50IRE) 0.25 1x(F1.35,50IRE) 1.4 1x(F1.6,50IRE)
PPaann && TTiillt
t
Continuous 360 Pan
(0.1-200 per second).
Tilt +60° to -90° depending
on set up
IIRR wwaavveelleennggtth
h
850nm (semi covert)
PPrreesseettss//TToouurrs
s
100 presets with programmable
940nm covert wavelength available to special order
titles & 8 tours with
programmable titles
IIRR rraanngge
e
Tested to 100m (850nm)
PPaasssswwoorrdd pprrootteeccttiioon
n
Yes (three levels)
CCaammeerraa ttiittlle
e
s
s
16 alphanumeric characters
PPrreesseett ttiittllees
s
16 alphanumeric characters
PPrriivvaaccyy zzoonnees
s
24 programmable
Camera head material Die cast aluminium
AAllaarrmm hhaannddlliinng
g
Weekend/weekday time
WWiinnddoow
w
Flat toughened glass schedules for enabling/disabling
OOppeerraattiinngg tteemmppeerraattuurre
e
-35
˚
C to 50˚C heater/Fan alarms
CCaammeerraa hheeaadd WWeeiigghht
t
6.5 Kilos
VViiddeeoo llaauunncchh aammpplliiffiieer
r
0-6dB 8 steps
PPaaiinntt ffiinniissh
h
Powder coat
HHeeaatteer
r
Yes
IIPP RRaattiinng
g
IP66
FFaan
n
Yes
Intermittent and Wiper Time Out
FFeeaattuurrees
s
16 Alarm inputs (volt free).
1 relay o/p fits to RV-PSU.
Optional wireless card up to 16 PIRs
IInnppuut
t
110V to 240Vac, 50MZ
TTyyppe
e
Pedestal, Swan, pedestal (tower
OOuuttppuut
t
24V DC @ 2A output mount) wall, corner, pendant &
PPoowweerr CCoonnssuummppttiioon
n
2 Amps at 48VA pole clamp
X-SERIESTMUSER MANUAL
37
13 CONTACT TECHNICAL SUPPORT
Redvision Technical Support Helpline tel: +44 (0) 1420 448 448
email: support@redvisioncctv.com web: www.redvisioncctv.com/support
14 TECHNICAL SPECIFICATION
CAMERA TELEMETRY
MECHANICAL
INFRA RED ILLUMINATION (RVX-IR version)
ENVIRONMENTAL & PHYSICAL
KEY FEATURES
WIPER (Optionally available on all models) OPTIONAL ALARM MODULE
MOUNTING BRACKETS
WARNING: THIS IS A CLASS A PRODUCT. IF INSTALLED IN A STATIC ENVIRONMENT RADIO
INTERFERENCE MAY BE CAUSED IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES.
POWER CONSUMPTION
This product is marked and has been fully tested and complies with:
2004/108/eec Electromagnetic Compatibility
73/23/eec Low Voltage Directives
60950:2006 Safety Standards
Redvision CCTV Limited (Redvision) warrants the buyer that the product will, on the date of shipment be free from defects in material & workmanship and will conform to Redvision’s specifications provided to the buyer. If any defect in material or workmanship appears in the product, Redvision will at its option, either repair or replace the defective product without charge at Redvision’s customer service centre or serviced authorised repair facility or credit or refund the purchase price of the defective product provided;
The defect appears within 24 months from the date of purchase by the end user
Examination of the product confirms that the claimed defect actually exists.
Buyer shall follow Redvision’s instructions regarding return of the defective product and no product will be accepted for repair, replacement, credit or refund without the written authorisation of Redvision or in accordance with Redvision’s written instructions. In the case of any such return the buyer shall bear the risk of loss or damage and shall prepay all transportation charges to Redvision. Repaired or replacement product will be shipped with freight prepaid by Redvision and the buyer shall bear the risk of loss or damage. The replaced product shall become Redvision’s property.
In no event shall Redvision be responsible for de-installation or reinstallation of the product or for the expenses thereof. If it is determined that product is not defective, the buyer shall pay Redvision all costs of handling, inspection, repairs and transportation at Redvision’s then prevailing rates.
Repairs and replacements covered by the above warranty are warranted to be free from defects as set forth above except that the defect must appear;
Within three (3) months from the date of repair or replacement; or
Prior to the expiration of the above twenty four (24) month period, whichever is later.
With respect to product not manufactured by Redvision, to the extent permitted, extends the warranties and affords the remedies to the buyer given to Redvision by its vendor of said products. The foregoing warranties do not extend;
To expendable items
To experimental or development products
To product which has been subjected to misuse, neglect, accident or abuse;
To the unauthorised repair or alteration by anyone other than Redvision;
To improper installation, storage or maintenance by anyone other than Redvision;
To product used in material violation of Redvision’s instruction; or
To product which has had its serial numbers or month and year of manufacture or shipment removed, defaced or altered or
To software.
The term “software” means a set of logical instructions and table of information which guide the functioning of a processor. Such set may be contained in any medium whatsoever including, without limitation, hardware containing a pattern of bits representing such set, provided, however, the term “software” does not mean or include the medium.
Redvision shall charge for the repair of all product returned out of warranty.
call Redvision Customer Service +44 (0) 1420 448 448 for an RMA number.
or visit www.redvisioncctv.com for more information.
Due to a policy of continuous product development the content of this manual may change without notice. Redvision CCTV Limited will endeavour to ensure the latest version is made available through the download section on its website www.redvisioncctv.com. Copyright © 2008 - 2011 Redvision CCTV Limited. All rights reserved. Redvision CCTV, the Redvision Logo, Redvision X-series™ RV Camera Series™, Redzone™ IR Illuminator are trademarks or registered trademarks of Redvision CCTV Limited.
Redvision CCTV Limited 17 Highview business park High Street Bordon Hampshire GU35 0AX United Kingdom
Company registration UK3952814
www.redvisioncctv.com
X-SERIESTMUSER MANUAL
15 WARRANTY INFORMATION
X-SERIESTMUSER MANUAL
X-SERIES
Loading...