All rights reserved. Red Lion, the Red Lion logo and N-Tron are registered trademarks of Red Lion Controls,
Inc. All other company and product names are trademarks of their respective owners.
The information contained in this document is subject to change without notice. Red Lion makes no warranty
of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability
or fitness for a particular purpose. In no event shall Red Lion be liable for any incidental, special, indirect or
consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions
in this manual or the information contained herein.
Portions of this document are intended solely as an outline of methodologies to be followed during the
maintenance and operation of N-Tron® Series 1000 equipment. It is not intended as a step-by-step guide or a
complete set of all procedures necessary and sufficient to complete all operations.
While every effort has been made to ensure that this document is complete and accurate at the time of release, the
information that it contains is subject to change. Red Lion Controls is not responsible for any additions to or
alterations of the original document. Industrial networks vary widely in their configurations, topologies, and traffic
conditions. This document is intended as a general guide only. It has not been tested for all possible applications,
and it may not be complete or accurate for some situations.
Users of this document are urged to heed warnings and cautions summarized at the front of the document, such as
electrical hazard warnings.
Compliance Information
It is recommended that the owner of this equipment determine and ensure conformance with any specific and
applicable local regulations.
Part 15 of the Federal Communications Commission (FCC) - A Rules: Interference
Every effort has been made to ensure that this equipment is designed to comply with the limits for a Class A digital
device, as described in the FCC Rules.
This product complies with Part 15 of the FCC-A Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful Interference
2. This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Operation of this device in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at their own expense.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment
Regulations. Operation is subject to the following two conditions; (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des
règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas
causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris
l'interférence qui peut causer l'opération peu désirée.
N-Tron® Series 1000 Hardware Guideiii
Revised 2016-08-30Preface
Drawing No. LP1001
Environmental Impact Statement
Red Lion equipment contains no hazardous materials as defined by the United States Environmental Protection
Agency (USEPA). Red Lion recommends that all failed product be returned to Red Lion for failure analysis and
proper disposal.
Toxic Emissions
Red Lion equipment releases no toxic emissions.
Trademark Acknowledgments
Ethernet is a registered trademark of Xerox Corporation. All other company and product names are trademarks of
their respective owners.
Release Notes and Document Updates
The hard copy and electronic media versions of this document are revised only at major releases and therefore,
may not always contain the latest product information. As needed, Documentation Notes and or Product Bulletins
will be provided between major releases to describe any new information or document changes.
The latest online version of this document and all product
http://www.redlion.net/documentation.
at
updates can be accessed through the Red Lion web site
Publication History
The following information lists the release history of this document.
ISSUE/REVISIONRELEASE DATECONTENT DESCRIPTION
Revised 2014-01-23January 2014Document Updates
Revised 2015-03-17March 2015Added 1008TX Model, Format Changes
Revised 2015-03-24March 2015Format Changes to Cover, Page Header and Tables
Revised 2016-08-30August 2016Add 1008TX-POE+ model
Related Documents
Visit the Technical Resources page on the Red Lion website at the following link to view available documents
related to this product.
Red Lion appreciates all comments that will help us to improve our documentation quality. The user can submit
comments through the Red Lion Customer Service. Simply email us at
customer.service@redlion.net
Additional Product Information
Additional product information can be obtained by contacting the local sales representative or Red Lion through the
contact numbers and/or e-mail addresses listed on the inside of the front cover.
ivN-Tron® Series 1000 Hardware Guide
PrefaceRevised 2016-08-30
Drawing No. LP1001
Warnings and Cautions
Warnings apply to situations where personal injury or death may result.
Cautions apply to where reduced function or damage to equipment may result.
General Safety Cautions and Warnings
CAUTION: If the N-Tron series equipment is used in the manner not specified by RedLion, the
protection provided by the equipment may be impaired.
ATTENTION: Si
la protection fournie par l'équipement peut être compromise.
CAUTION: Do not perform any services on the unit unless qualified to do so. Do not substitute
unauthorized parts or make unauthorized modifications to the unit.
ATTENTION:
substituer pièces non autorisées ou de modifications non autorisées de l'appareil.
l' N-Tron série équipement est utilisé d'une manière non spécifiée par Red Lion,
Ne pas effectuer de services sur l'appareil s'il n'est pas qualifié pour le faire. Ne pas
CAUTION: Do not operate the equipment in a manner not specified by this manual.
ATTENTION: Ne pas faire fonctionner l'équipement d'une manière non spécifiée par ce manuel.
WARNING: Install only in accordance with Local and National Codes of authorities having
jurisdiction.
ALERTE: Installer uniquement, conformément aux codes locau
compétence.
Electrical Safety Warnings
WARNING: Do not work on equipment or cables during periods of lightning activity.
ALERTE: Ne pas travailler sur le matériel ou les câbles pendant les périodes d'activité de la
foudre.
x et nationaux des autorités ayant
N-Tron® Series 1000 Hardware Guidev
Revised 2016-08-30Preface
Drawing No. LP1001
WARNING: Properly ground the unit before connecting anything else to the unit. Units not
properly grounded may result in a safety risk and could be hazardous and may void the warranty.
See the grounding technique section of this Hardware Guide for proper ways to ground the unit.
ALERTE: Correctement à la terre de l'unité avant tout raccordement à l'unité. Unités pas
correctement mise à la terre peut entraîner un risque de sécurité et pourraient être dangereux et
peut annuler la garantie. Voir la section technique de mise à la terre de ce mode d'emploi des
moyens appropriés à la masse de l'appareil.
WARNING: This equipment must be used with a Listed UL Industrial Power Supply.
ALERTE: Cet équipement doit être utilisé avec une
alimentation UL Listed industrielle.
WARNING: This equipment (1005TX,1008TX and 1008-TXPOE+) must be used with a Listed UL
Class 2 Power Supply.
ALERTE: Cet équipement (1005TX,1008TX and 1008-TXPOE+) d
oit être utilisé avec une alimen-
tation UL Listed Classe 2.
WARNING: A Recognized or Listed fuse, rated maximum 3A, minimum 30VDC, must be installed
on the line side of the device.
ALERTE:
Un fusible reconnu ou classé, classé 3A maximale, 30VDC minimum, doit être installé
sur le côté de la ligne de l'appareil.
WARNING: Use 110°C or higher rated copper wire, (0.22Nm) 2 lb/in tightening torque for field
installed conductors.
ALERTE: Utilisez 110°C ou nominale supérieure fil de cuivre, (0,22 Nm) 2 lb/pouce couple de
serrage pour le champ installé conducteurs.
WARNING: Do not operate the unit with the end plates removed, as this could create a shock or
fire hazard.
ALERTE : N
e pas faire fonctionner l'unité avec les plaques d'extrémité retiré, ce qui pourrait créer
une décharge électrique ou un incendie.
CAUTION: Observe proper DC Voltage polarity when installing power input cables. Reversing
voltage polarity can cause permanent damage to the unit and voids the warranty.
ATTENTION: Respecter la polarité correcte de tension DC lors de l'installation des câbles
d'alimentation d'entrée. Inversion de polarité de tension peut causer des dommages permanents à
l'appareil et annule la garantie.
viN-Tron® Series 1000 Hardware Guide
PrefaceRevised 2016-08-30
Drawing No. LP1001
Environmental Safety Cautions and Warnings
CAUTION: This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or
non-hazardous locations only.
ATTENTION: Cet équipement est adapté pour une utilisation dans la classe I, Division 2, Groupes
A, B, C et D ou non dangereux endroits seulement.
WARNING: Expl
osion Hazard – Substitution of components may impair suitability for Class I,
Division 2.
ALERTE - Risque d'explosion - Remplacement d'un composant peut empêcher la conformité de
Classe I, Division 2.
WARNING: Do not operate the equipment in the presence of flammable gases or fumes. Operating electrical equipment in such an environment constitutes a definite safety hazard.
ALERTE : Ne pas utiliser le matériel en présence de gaz ou de vapeurs inflammables. L'utilisation
de matériel électrique dans un tel environnement constitue un danger certain.
WARNING – Explosion Hazard – Do not connect or disconnect any connections while circuit is
live unless area is known to be non-hazardous.
ALERTE - Risque d'explosion - Ne pas brancher ou débrancher les connexions lorsque le circuit
est sous tension sauf si la zone est connue pour être non dangereux.
WARNING: Disconnect the power and allow to cool 5 minutes before touching.
ALERTE: D
éconnectez le câble d'alimentation et laisser refroidir 5 minutes avant de la toucher.
Hazardous Location Warning
WARNING (1005TX ,1008TX and 1008TX-POE+ only): This equipment is open-type device and
is meant to be installed in an enclosure suitable for the environment that is only accessible with
the use of a tool.
ALERTE (1005TX ,1008TX and 1008-TXPOE+ uniquement): Cet équipement est ouvert de type
périphérique et est destiné à être installé dans un boîtier adapté à l'environnement qui n'est
accessible qu'avec l'utilisation d'un outil.
N-Tron® Series 1000 Hardware Guidevii
Revised 2016-08-30Preface
Drawing No. LP1001
Laser Safety Warning
CAUTION (1002MC and 1003GX2 only): CLASS 1 LASER PRODUCT. Do not stare into the
laser.
ATTENTION (1002MC et 1003GX2 uniquement): PRODUIT LASER CLASSE 1. Ne pas regarder
dans le laser.
viiiN-Tron® Series 1000 Hardware Guide
Introduction and SpecificationsRevised 2016-08-30
Drawing No. LP1001
Section 1 Introduction and Specifications
Introduction
The N-Tron® Series 1000 Unmanaged Industrial Gigabit Ethernet Switches and Media Converters are housed in
ruggedized enclosures, and provide Category-5 compliant 10/100/1000Base-T connections for high performance
network design. The 1000 series switches support high speed layer 2 switching between ports.
Fiber models utilize IEEE compliant LC duplex connectors for fiber optic communications in a convenient SFP
(Small Form Pluggable) modular design. All 10/100/1000Base-T ports utilize RJ45 shielded connectors.
• The 1002MC is a two port unmanaged media converter that converts 10/100/1000Base-T copper to
1000BaseSX/LX SFP port.
• The 1003GX2 is a three port unmanaged Gigabit switch that offers one 10/100/1000Base-T copper port and
two 1000BaseT/SX/LX SFP ports.
• The 1005TX is a five port unmanaged Gigabit switch that offers five 10/100/1000Base-T copper ports.
• The 1008TX is an eight port unmanaged Gigabit switch that offers eight 10/100/1000Base-T copper ports.
• The 1008TX-POE+ is an eight port unmanaged Gigabit switch that offers eight 10/100/1000Base-T copper
ports, including 4 PoE+ capable ports (up to 30 Watts each).
Red Lion’s industrial Power over Ethernet (PoE) solutions are designed to transmit power and data over an
Ethernet network. PoE networks eliminate the need for running separate wires for power and are ideal in
installations with devices such as IP surveillance cameras, wireless access points, IP phones and other PoEenabled devices. These industrial PoE devices offer a compact, rugged design for harsh, remote locations.
Key Features
• Compact Space Saving Package
• Unmanaged Operation
• Jumbo Frame Support (1005TX and 1008TX only)
• Extended Environmental Specifications
• Supports Full/Half Duplex Operation
• Up to 16.0 Gb/s Maximum Throughput
• MDIX Auto Sensing Cable
• Auto Sensing Speed and Flow Control
• Full Wire Speed Communication
• Store-and-Forward Switching Technology
• Redundant Power Inputs
• LED Link/Activity Status Indication
• Industry Standard 35mm DIN-Rail Mounted Enclosure
• Plug-and Play installation
N-Tron® Series 1000 Hardware Guide1-1
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.