red lion N-Tron 1000 Series, N-Tron 1005TX, N-Tron 1002MC, N-Tron 1003GX2, N-Tron 1008TX Hardware Manual

N-Tron® 1000 Series
Industrial Gigabit Media Converters & Gigabit Ethernet Switches
Hardware Guide | March 2015
COPYRIGHT
Copyright, © 2015 Red Lion Controls, Inc. 20 Willow Springs Circle York, PA 17406 All rights reserved. Red Lion, the Red Lion logo and N-Tron are registered trademarks of Red Lion Controls,
Inc. All other company and product names are trademarks of their respective owners. The information contained in this document is subject to change without notice. Red Lion makes no warranty
of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability or fitness for a particular purpose. In no event shall Red Lion be liable for any incidental, special, indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein.
CONTACT INFORMATION :
AMERICAS
York, PA: +1 (717) 767-6511 Mobile, AL: +1 (251) 342-2164 Ballston Lake, NY: +1 (518) 877-5173 Hours: 8am-6pm Eastern Standard Time (UTC/GMT -5 hours)
ASIA-PACIFIC
Shanghai, P.R. China: +86 21-6113-3688 x767 Hours: 10am-6pm China Standard Time (UTC/GMT +8 hours)
EUROPE
The Netherlands: +31 33-4723-225 Hours: 9am-6pm Central European Time (UTC/GMT +1 hour)
Table of Contents Revised 2015-03-24
Table of Contents
Preface
Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Compliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Part 15 of the Federal Communications Commission (FCC) - A Rules: Interference . . . . . . iii
Industry Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Environmental Impact Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Toxic Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Trademark Acknowledgments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Release Notes and Document Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Publication History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Document Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Additional Product Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
General Safety Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Electrical Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Environmental Safety Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Hazardous Location Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Laser Safety Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Introduction and Specifications
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Product Ordering Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Model 1002MC Key Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Model 1002MC Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Model 1003GX2 - Key Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Model 1003GX2 Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
N-Tron 1000 Series Hardware Guide i
Table of Contents Revised 2015-03-24
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Model 1005TX - Key Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Model 1005TX Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
Model 1008TX - Key Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Model 1008TX Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Installation
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Installing/Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
DIN-Rail Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Power Connection (Top View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Ground Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
N-Tron Series Switch Grounding Techniques for 1000 Series . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
Operation and Maintenance
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
Model 1002MC, 1003GX2, 1005TX Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
Model 1008TX Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
Verify/Troubleshoot Cable Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
Red Lion Controls N-Tron 1000 Series Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
ii N-Tron 1000 Series Hardware Guide
Preface Revised 2015-03-24
Preface
Disclaimer
Portions of this document are intended solely as an outline of methodologies to be followed during the maintenance and operation of N-Tron 1000 Series equipment. It is not intended as a step-by-step guide or a complete set of all procedures necessary and sufficient to complete all operations.
While every effort has been made to ensure that this document is complete and accurate at the time of release, the information that it contains is subject to change. Red Lion Controls is not responsible for any additions to or alterations of the original document. Industrial networks vary widely in their configurations, topologies, and traffic conditions. This document is intended as a general guide only. It has not been tested for all possible applications, and it may not be complete or accurate for some situations.
Users of this document are urged to heed warnings and cautions summarized at the front of the document, such as electrical hazard warnings.
Compliance Information
It is recommended that the owner of this equipment determine and ensure conformance with any specific and applicable local regulations.
Part 15 of the Federal Communications Commission (FCC) - A Rules: Interference
Every effort has been made to ensure that this equipment is designed to comply with the limits for a Class A digital device, as described in the FCC Rules.
This product complies with Part 15 of the FCC-A Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful Interference
2. This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions; (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée.
N-Tron 1000 Series Hardware Guide iii
Preface Revised 2015-03-24
Environmental Impact Statement
Red Lion equipment contains no hazardous materials as defined by the United States Environmental Protection Agency (USEPA). Red Lion recommends that all failed product be returned to Red Lion for failure analysis and proper disposal.
Toxic Emissions
Red Lion equipment releases no toxic emissions.
Trademark Acknowledgments
Ethernet is a registered trademark of Xerox Corporation.
EtherNet/IPTM and CIPTM are registered trademarks of ODVA.
Release Notes and Document Updates
The hard copy and electronic media versions of this document are revised only at major releases and therefore, may not always contain the latest product information. As needed, Documentation Notes and or Product Bulletins will be provided between major releases to describe any new information or document changes.
The latest online version of this document and all product updates can be accessed through the Red Lion web site.
Publication History
The following information lists the release history of this document.
ISSUE/REVISION RELEASE DATE CONTENT DESCRIPTION
Revised 2014-01-23 January 2014 Document Updates
Revised 2015-03-17 March 2015 Added 1008TX Model, Format Changes
Revised 2015-03-24 March 2015 Format Changes to Cover, Page Header and Tables
Related Documents
Visit the Technical Resources page on the Red Lion website at the following link to view available documents related to this product.
Document Comments
Red Lion appreciates all comments that will help us to improve our documentation quality. The user can submit comments through the Red Lion Customer Service. Simply email us.
Additional Product Information
Additional product information can be obtained by contacting the local sales representative or Red Lion through the contact numbers and/or e-mail addresses listed on the inside of the front cover.
iv N-Tron 1000 Series Hardware Guide
Preface Revised 2015-03-24
Warnings and Cautions
Warnings apply to situations where personal injury or death may result.
Cautions apply to where reduced function or damage to equipment may result.
General Safety Cautions and Warnings
CAUTION: If the N-Tron series equipment is used in the manner not specified by Red Lion, the protection provided by the equipment may be impaired.
ATTENTION: Si l' N-Tron série équipement est utilisé d'une manière non spécifiée par Red Lion, la protection fournie par l'équipement peut être compromise.
CAUTION: Do not perform any services on the unit unless qualified to do so. Do not substitute unauthorized parts or make unauthorized modifications to the unit.
ATTENTION: Ne pas effectuer de services sur l'appareil s'il n'est pas qualifié pour le faire. Ne pas substituer pièces non autorisées ou de modifications non autorisées de l'appareil.
CAUTION: Do not operate the equipment in a manner not specified by this manual.
ATTENTION: Ne pas faire fonctionner l'équipement d'une manière non spécifiée par ce manuel.
WARNING: Install only in accordance with Local and National Codes of authorities having
jurisdiction.
ALERTE: Installer uniquement, conformément aux codes locaux et nationaux des autorités ayant compétence.
Electrical Safety Warnings
WARNING: Do not work on equipment or cables during periods of lightning activity.
ALERTE: Ne pas travailler sur le matériel ou les câbles pendant les périodes d'activité de la
foudre.
N-Tron 1000 Series Hardware Guide v
Preface Revised 2015-03-24
WARNING: Properly ground the unit before connecting anything else to the unit. Units not properly grounded may result in a safety risk and could be hazardous and may void the warranty. See the grounding technique section of this Hardware Guide for proper ways to ground the unit.
ALERTE: Correctement à la terre de l'unité avant tout raccordement à l'unité. Unités pas correctement mise à la terre peut entraîner un risque de sécurité et pourraient être dangereux et peut annuler la garantie. Voir la section technique de mise à la terre de ce mode d'emploi des moyens appropriés à la masse de l'appareil.
WARNING: This equipment must be used with a Listed UL Industrial Power Supply.
ALERTE: Cet équipement doit être utilisé avec une alimentation UL Listed industrielle.
WARNING: This equipment (1005TX and 1008TX) must be used with a Listed UL Class 2 Power
Supply.
ALERTE: Cet équipement (1005TX and 1008TX) doit être utilisé avec une alimentation UL Listed Classe 2.
WARNING: A Recognized or Listed fuse, rated maximum 3A, minimum 30VDC, must be installed on the line side of the device.
ALERTE: Un fusible reconnu ou classé, classé 3A maximale, 30VDC minimum, doit être installé sur le côté de la ligne de l'appareil.
WARNING: Use 110°C or higher rated copper wire, (0.22Nm) 2 lb/in tightening torque for field installed conductors.
ALERTE: Utilisez 110°C ou nominale supérieure fil de cuivre, (0,22 Nm) 2 lb/pouce couple de serrage pour le champ installé conducteurs.
WARNING: Do not operate the unit with the end plates removed, as this could create a shock or fire hazard.
ALERTE : Ne pas faire fonctionner l'unité avec les plaques d'extrémité retiré, ce qui pourrait créer une décharge électrique ou un incendie.
CAUTION: Observe proper DC Voltage polarity when installing power input cables. Reversing voltage polarity can cause permanent damage to the unit and voids the warranty.
ATTENTION: Respecter la polarité correcte de tension DC lors de l'installation des câbles d'alimentation d'entrée. Inversion de polarité de tension peut causer des dommages permanents à l'appareil et annule la garantie.
vi N-Tron 1000 Series Hardware Guide
Preface Revised 2015-03-24
Environmental Safety Cautions and Warnings
CAUTION: This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous locations only.
ATTENTION: Cet équipement est adapté pour une utilisation dans la classe I, Division 2, Groupes A, B, C et D ou non dangereux endroits seulement.
WARNING: Explosion Hazard – Substitution of components may impair suitability for Class I, Division 2.
ALERTE - Risque d'explosion - Remplacement d'un composant peut empêcher la conformité de Classe I, Division 2.
WARNING: Do not operate the equipment in the presence of flammable gases or fumes. Operat­ing electrical equipment in such an environment constitutes a definite safety hazard.
ALERTE : Ne pas utiliser le matériel en présence de gaz ou de vapeurs inflammables. L'utilisation de matériel électrique dans un tel environnement constitue un danger certain.
WARNING – Explosion Hazard – Do not connect or disconnect any connections while circuit is live unless area is known to be non-hazardous.
ALERTE - Risque d'explosion - Ne pas brancher ou débrancher les connexions lorsque le circuit est sous tension sauf si la zone est connue pour être non dangereux.
WARNING: Disconnect the power and allow to cool 5 minutes before touching.
ALERTE: Déconnectez le câble d'alimentation et laisser refroidir 5 minutes avant de la toucher.
Hazardous Location Warning
WARNING (1005TX and 1008TX only): This equipment is open-type device and is meant to be installed in an enclosure suitable for the environment that is only accessible with the use of a tool.
ALERTE (1005TX and 1008TX uniquement): Cet équipement est ouvert de type périphérique et est destiné à être installé dans un boîtier adapté à l'environnement qui n'est accessible qu'avec l'utilisation d'un outil.
N-Tron 1000 Series Hardware Guide vii
Preface Revised 2015-03-24
Laser Safety Warning
CAUTION (1002MC and 1003GX2 only): CLASS 1 LASER PRODUCT. Do not stare into the laser.
ATTENTION (1002MC et 1003GX2 uniquement): PRODUIT LASER CLASSE 1. Ne pas regarder dans le laser.
viii N-Tron 1000 Series Hardware Guide
Introduction and Specifications Revised 2015-03-24
Section 1 Introduction and Specifications
Introduction
The N-Tron 1000 Series Unmanaged Industrial Gigabit Ethernet Switches support high speed layer 2 switching between ports. This series of switches are housed in a ruggedized aluminum enclosure, and provide Category-5 compliant 10/100/1000Base-T connections for high performance network design, and hub/repeater upgrades.
All fiber products utilize the IEEE compliant LC duplex connectors for fiber optic communications in a convenient SFP (Small Form Pluggable) modular design. All 10/100/1000Base-T ports utilize the RJ45 shielded connectors.
The 1002MC/MCE is a two port unmanaged media converter that converts 10/100/1000Base-T copper to 1000BaseSX/LX full duplex fiber.
The 1003GX2/GXE2 is a three port unmanaged switch that offers one 10/100/1000Base-T copper port and two 1000BaseT/SX/LX full duplex copper/fiber ports.
The 1005TX is a five port unmanaged switch that offers five 10/100/1000Base-T copper ports.
The 1008TX is an eight port unmanaged switch that offers eight 10/100/1000Base-T copper ports.
Key Features
Compact Space Saving Package
Full IEEE 802.3 Compliance
Unmanaged Operation
Jumbo Frame Support (1005TX and 1008TX only)
Extended Environmental Specifications
-40°C to 85°C Operating and Storage Temperature
Supports Full/Half Duplex Operation
Up to 16.0 Gb/s Maximum Throughput
MDIX Auto Sensing Cable
Auto Sensing Speed and Flow Control
Full Wire Speed Communication
Store-and-Forward Switching Technology
Redundant Power Inputs (10-30 VDC, 10-49VDC for 1008TX)
LED Link/Activity Status Indication
Hardened Metal Enclosure
Industry Standard 35mm DIN Rail Mounted Enclosure
N-Tron 1000 Series Hardware Guide 1-1
Introduction and Specifications Revised 2015-03-24
Product Ordering Guide
The 1000 Series Media Converter and Unmanaged Industrial Gigabit Ethernet Switch model part numbers and net­work applications are presented in Table 1.
Table 1. Ordering Guide
PART NUMBER APPLICATION
1002MC-SX 1000BaseSX Multimode fiber Media Converter
1002MC-LX-YY 1000BaseLX Singlemode fiber Media Converter
1003GX2 Three port; One 10/100/100BaseT; Two 1000BaseSX/LX Gigabit Ethernet Switch
1003GX2-B One 10/100/1000BaseT port; Two 1000BaseSX/LX ports with mix-and-match SFP Mini-GBIC
fiber transceivers. Note: Unit must be populated with two SFP transceivers upon shipment
1003GX2-SX One 10/100/1000BaseT port; Two (2) 1000BaseSX SFP Mini-GBIC fiber transceivers
1003GX2-LX-10 One 10/100/1000BaseT port; Two (2) 1000BaseLX-10 SFP transceivers
1003GX2-LX-40 One 10/100/1000BaseT port; Two (2) 1000BaseLX-40 SFP transceivers
1003GX2-LX-80 One 10/100/1000BaseT port; Two (2) 1000BaseLX-80 SFP transceivers
1005TX Five port 10/100/1000BaseT Gigabit Ethernet switch
1008TX Eight port 10/100/1000BaseT Gigabit Ethernet switch
NTSFP-SX One 1000BaseSX Multimode SFP Gigabit Transceiver with LC Style Connector for up to
550m fiber segment length (two required per unit)
NTSFP-LX-ZZ One 1000BaseLX Singlemode SFP Gigabit Transceiver with LC Style Connector for up to ZZ
fiber segment length (two required per unit)
NTPS-24-1.3 DIN-Rail Power Supply 24V@1.3 amp; Used with all models
1000-PM Panel Mount kit; Used with all models
Where: “YY” or “ZZ” is: 10 for 10km maximum fiber segment length
40 for 40km maximum fiber segment length 80 for 80km maximum fiber segment length
N-Tron 1000 Series Hardware Guide 1-2
Introduction and Specifications Revised 2015-03-24
Model 1002MC Key Specifications
Table 2. 1002MC - Key Specifications
PHYSICAL ELECTRICAL
Height 4.0” (10.16 cm) Input Voltage 10-30 VDC (Regulated)
Width 1.0” (2.54 cm) Input Current 200mA max. @ 24VDC
(Steady State)
Depth w/ typical SFP installed 3.61” (9.165 cm) Inrush Current 13 Amp/0.8 ms max. @
24VDC
Weight 0.70 lbs (0.32 kg) Input Ripple Less than 100 mV
DIN Rail 35 mm Input Wire Size 12-24 AWG
ENVIRONMENTAL NETWORK MEDIA
Operating Temperature -40°C to 85°C 10BaseT Cat-3
Storage Temperature -40°C to 85°C 100BaseT Cat-5
Operating Humidity 10% to 90%
(Non Condensing)
Operating Altitude 0 to 10,000 ft. 1000BaseSX Multimode 50-62.5/125m
1000BaseT Cat-5e
1000BaseLX Singlemode 7-10/125m
CONNECTOR RECOMMENDED MINIMUM WIRING CLEARANCE
10/100/1000BaseTX One (1) RJ45 TX Copper Port Top 1 " (2.54 cm)
1000Base-X SFP One (1) SFP LC Duplex
Gigabit Fiber Port
Front 4 " (10.16 cm)
Table 3. Gigabit Fiber Transceiver SFP Characteristics
NTSFP-SX NTSFP-LX-10 NTSFP-LX-40 NTSFP-LX-80
FIBER LENGTH
TX POWER MIN
RX SENSITIVITY MAX
WAVELENGTH
ASSUMED FIBER LOSS
LASER TYPE
550m with 50/125m
275m @ 62.5/125m
-9.5dBm -9.5dBm -2dBm 0dBm
-17dBm -20dBm -22dBm -24dBm
850nm 1310nm 1310nm 1550nm
3.5 to 3.75 dB/km 0.45 dB/km 0.35 dB/km 0.25 dB/km
VCSEL FP DFB DFB
10km 40km 80km
N-Tron 1000 Series Hardware Guide 1-3
Introduction and Specifications Revised 2015-03-24
Model 1002MC Regulatory Approvals
Safety
For use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.
UL 508, Industrial Control Equipment.
ANSI/ISA-12.12.01-2007 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous
(Classified) Locations Groups A, B, C, D. T4A.
cUL C22.2 No. 14-M05
cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.
EMI
EN61000-6-4, EN55011 - Class A
FCC Title 47, Part 15, Subpart B - Class A
ICES-003 – Class A
EMS
EN61000-6-2
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (Conducted Disturbances)
Warranty
3 years from the date of purchase.
N-Tron 1000 Series Hardware Guide 1-4
Introduction and Specifications Revised 2015-03-24
Model 1003GX2 - Key Specifications
Table 4. 1003GX2 Key Specifications
PHYSICAL ELECTRICAL
Height 4.0” (10.16 cm) Input Voltage 10-30 VDC (Regulated)
Width 1.0” (2.54 cm) Input Current 200mA max. @ 24VDC
(Steady State)
Depth w/ typical SFP installed
Weight 0.7 lbs (0.32 kg) Input Ripple Less than 100 mV
DIN Rail 35 mm Input Wire Size 12-24 AWG
ENVIRONMENTAL NETWORK MEDIA
Operating Temperature -40°C to 85°C 10BaseT Cat-3
Storage Temperature -40°C to 85°C 100BaseT Cat-5
Operating Humidity 10% to 90%
Operating Altitude 0 to 10,000 ft. 1000BaseSX Multimode 50-62.5/125m
3.61” (9.165 cm) Inrush Current 13 Amp/0.8 ms max. @ 24VDC
1000BaseT Cat-5e
(Non Condensing)
1000BaseLX Singlemode 7-10/125m
CONNECTORS RECOMMENDED MINIMUM WIRING CLEARANCE
10/100/1000BaseTX One (1) RJ45 TX Copper Port Top 1 " (2.54 cm)
1000Base-X SFP Up to two (2) SFP LC Duplex
Gigabit Fiber Ports
Front 4 " (10.16 cm)
Table 5. Gigabit Fiber Transceiver (SFP) Characteristics
NTSFP-SX NTSFP-LX-10 NTSFP-LX-40 NTSFP-LX-80
FIBER LENGTH
TX POWER MIN
RX SENSITIVITY MAX
WAVELENGTH
ASSUMED FIBER LOSS
LASER TYPE
550m with 50/125m 275m @ 62.5/125m
-9.5dBm -9.5dBm -2dBm 0dBm
-17dBm -20dBm -22dBm -24dBm
850nm 1310nm 1310nm 1550nm
3.5 to 3.75 dB/km 0.45 dB/km 0.35 dB/km 0.25 dB/km
VCSEL FP DFB DFB
10km 40km 80km
N-Tron 1000 Series Hardware Guide 1-5
Introduction and Specifications Revised 2015-03-24
Model 1003GX2 Regulatory Approvals
Safety
For use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.
UL 508, Industrial Control Equipment.
ANSI/ISA-12.12.01-2007 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous
(Classified) Locations Groups A, B, C, D. T4A.
cUL C22.2 No. 14-M05
cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.
EMI
EN61000-6-4, EN55011 - Class A
FCC Title 47, Part 15, Subpart B - Class A
ICES-003 – Class A
EMS
EN61000-6-2
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (Conducted Disturbances)
Warranty
3 years from the date of purchase.
N-Tron 1000 Series Hardware Guide 1-6
Introduction and Specifications Revised 2015-03-24
Model 1005TX - Key Specifications
Table 6. 1005TX Key Specifications
PHYSICAL ELECTRICAL
Height 4.0” (10.16 cm) Input Voltage 10-30 VDC (Regulated)
Width 1.0” (2.54 cm) Input Current 230mA max. @ 24VDC
(Steady State)
Depth w/ typical SFP installed
Weight 0.7 lbs (0.32 kg) Input Ripple Less than 100 mV
DIN Rail 35 mm Input Wire Size 12-24 AWG
ENVIRONMENTAL NETWORK MEDIA
Operating Temperature -40°C to 85°C 10BaseT Cat-3
Storage Temperature -40°C to 85°C 100BaseT Cat-5
Operating Humidity 10% to 90%
Operating Altitude 0 to 10,000 ft.
3.61” (9.165 cm) Inrush Current 13 Amp/0.61 ms max. @ 24VDC
1000BaseT Cat-5e
(Non Condensing)
CONNECTORS RECOMMENDED MINIMUM WIRING CLEARANCE
10/100/1000BaseTX Five (5) RJ45 TX Copper
Ports
Top 1 " (2.54 cm)
Front 2 " (5.08 cm)
Model 1005TX Regulatory Approvals
Safety
For use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.
UL 508, Industrial Control Equipment
ANSI/ISA-12.12.01-2007 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous
(Classified) Locations Groups A, B, C, D. T4
cUL C22.2 No. 14-M05
cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.
EMI
EN61000-6-4, EN55011 - Class A
FCC Title 47, Part 15, Subpart B - Class A
ICES-003 – Class A
N-Tron 1000 Series Hardware Guide 1-7
Introduction and Specifications Revised 2015-03-24
EMS
EN61000-6-2
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (Conducted Disturbances)
Warranty
3 years from the date of purchase.
N-Tron 1000 Series Hardware Guide 1-8
Introduction and Specifications Revised 2015-03-24
Model 1008TX - Key Specifications
Table 7. 1008TX Key Specifications
PHYSICAL ELECTRICAL
Height 4.63” (11.76 cm) Input Voltage 10-49 VDC (Regulated)
Width 1.55” (3.94 cm) Input Current 290mA max. @ 24VDC
(Steady State)
Depth w/ typical SFP installed
Weight 0.7 lbs (0.32 kg) Input Ripple Less than 100 mV
DIN Rail 35 mm Input Wire Size 12-24 AWG
ENVIRONMENTAL NETWORK MEDIA
Operating Temperature -40°C to 85°C 10BaseT Cat-3
Storage Temperature -40°C to 85°C 100BaseT Cat-5
Operating Humidity 10% to 90%(Non Condens-
Operating Altitude 0 to 10,000 ft.
4.08” (10.37 cm) Inrush Current 20 Amp/0.06 ms max. @ 24VDC
1000BaseT Cat-5e
ing)
CONNECTORS RECOMMENDED MINIMUM WIRING CLEARANCE
10/100/1000BaseTX Eight (8) RJ45 TX Copper
Ports
Top 1 " (2.54 cm)
Front 2 " (5.08 cm)
Model 1008TX Regulatory Approvals
Safety
For use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.
UL 508, Industrial Control Equipment.
ANSI/ISA-12.12.01-2013 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous (Classi-
fied) Locations Groups A, B, C, D. T4.
cUL C22.2 No. 14-M05
cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.
EMI
FCC Title 47, Part 15, Subpart B - Class A
Industry Canada ICES-003 – Class A
EN 55011 - Class A
EN 61000-6-4
EN 61000-3-2/3
N-Tron 1000 Series Hardware Guide 1-9
Introduction and Specifications Revised 2015-03-24
EMS
EN 61000-6-2
EN 61000-4-2/3/4/5/6/8/11
Warranty
3 years from the date of purchase.
N-Tron 1000 Series Hardware Guide 1-10
Installation Revised 2015-03-24
Section 2 Installation
Introduction
This sections contains the information and procedures necessary to unpack, inspect, install and connect the N-Tron 1000 Series equipment.
Unpacking
Remove all the equipment from the packaging, and store the packaging in a safe place.
Inspection
Please ensure the shipping package contains the following items in undamaged condition:
1. N-Tron 1000 Series Media Converter or Ethernet Switch.
2. Product CD.
If the package contents are damaged:
1. Contact your carrier.
2. File any damage claims with the carrier.
Installing/Mounting
Read the following warning before beginning the installation:
Lire l'avertissement suivant avant de commencer l'installation:
WARNING: Never install or work on electrical equipment or cabling during peri-
ods of lightning activity. Never connect or disconnect power when hazardous gases are present.
ALERTE: Ne jamais installer ou de travailler sur un équipement électrique ou de
câblage pendant les périodes d'activité de la foudre. Ne jamais brancher ou débrancher l'alimentation en gaz dangereux sont présents
N-Tron 1000 Series Hardware Guide 2-11
Installation Revised 2015-03-24
DIN-Rail Mounting
a. Install the unit in a standard DIN rail. Recess the unit to allow at least 2” of horizontal clearance for CAT5e
cable bend radius or 5” of horizontal clearance for Fiber Optic cable bend radius.
b. To install the unit to 35mm industrial DIN rail,
place the top edge of the included mounting bracket on the back of the unit against the DIN rail at a 15° angle as shown. Rotate the bottom of the unit to the back (away from you) until it snaps into place.
c. To remove the unit from the 35mm industrial
DIN rail, pull forward on the unit until it disen­gages from the bottom of the DIN rail. Rotate the bottom of the unit towards you and up at an approximate 15° upward angle to completely remove the unit.
URMK 1000-PM
Most Red Lion N-Tron™ products are designed to be mounted on industry standard 35mm DIN rail. However, DIN rail mount­ing may not be suitable for all applications. Our Universal Rack Mount Kit (P/N: URMK) can be used to mount the 1000 Series enclosures to standard 19" racks, and our Panel Mount Assembly (P/N: 1000-PM) can be used to mount the 1000 Series enclosures to a panel or any other flat surface.
N-Tron 1000 Series Hardware Guide 2-12
Installation Revised 2015-03-24
Connections
Power Connection (Top View)
1. Unscrew & Remove the DC Voltage Input Plug from the top header.
2. Install the DC Power Cables into the Plug (observing polarity on unit).
3. Plug the Voltage Input Plug back into the top header.
4. Tightening torque for the terminal block power plug is 0.5 Nm/0.368 Pound Foot.
5. Verify the Power LED stays ON (GREEN).
Note: Either V1 or V2 can be connected to power for minimal operation. For redundant power opera-
tion, V1 and V2 plugs must be connected to separate DC Voltage sources. Use wire sizes of 12-24 gauge. Limit he power cord length to less than 10 meters in order to ensure optimum performance.
Recommend using 24V DC Power Supplies, similar to:
100-240VAC:N-Tron NTPS-24-1.3, DC 24V/1.3A
Ground Connection
N-Tron Series Switch Grounding Techniques for 1000 Series
The grounding philosophy of any control system is an integral part of the design. N-Tron series switches are designed to be grounded, but the user has been given the flexibility to float the switch when required. The best noise immunity and emissions (i.e. CE) are obtained when the N-Tron switch chassis is connected to earth ground via a drain wire. Some N-Tron series switches have metal din-rail brackets that can ground the switch if the din-rail is grounded. In some cases, N-Tron series switches with metal brackets can be supplied with optional plastic brackets if isolation is required.
N-Tron 1000 Series Hardware Guide 2-13
Installation Revised 2015-03-24
Users may run a drain wire & lug from the screw provided on the back face of the enclosure. In the event the provided grounding screw has been lost, care should be taken to limit the penetration of the outer skin by less than 1/4". Failure to do so may cause irreversible damage to the internal components of the switch.
Note: Ensure the power supply is grounded properly before applying power to the grounded switch. This can be verified by using a voltmeter to determine that there is no voltage difference between the power supply’s negative output terminal and the chassis grounding point of the switch.
Drain wire with lug connecting switch chassis to known god grounding posts.
Note: The V-legs of the power input connector are connected to the chassis internally on the 1002MC, 1003GX2 and 1005TX. Before applying power to the grounded switch, you must use a volt meter to verify there is no voltage difference between the power supply’s negative output ter­minal and the switch chassis grounding point.
If the use of shielded cables is required, it is generally recommended to only connect the shield at one end to pre­vent ground loops and interfere with low level signals (i.e. thermocouples, RTD, etc.). Cat5e cables manufactured to EIA-568A or 568B specifications are required for use with N-Tron series switches.
In the event all Cat5e patch cable distances are small (i.e. All Ethernet devices are located the same local cabinet and/or referenced to the same earth ground), it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals.
N-Tron 1000 Series Hardware Guide 2-14
Installation Revised 2015-03-24
Cable Connection
Cable connections are dependent on the network configuration and N-Tron 1000 Series model in use.
1. For 10Base-T ports, plug a Category 3 (or greater) twisted pair cable into the RJ45 connector.
2. For 100/1000Base-T ports, plug a Category 5e (or greater) twisted pair cable into the RJ45 connector. Con-
nect the other end to the far end station.
3. Verify that the LNK/ACT LEDs are ON once the connection has been completed.
4. To connect any other port to another Switch or Repeater, use a standard Cat5e straight through or crossover
cable.
CAUTION: Creating a port to port connection on the same switch (i.e. loop) is an illegal operation and will create a broadcast storm which will crash the network!
ATTENTION: Création d'un port de connexion du port sur le même commutateur (c.-à-boucle) est une opération illégale et va créer une tempête de diffusion qui va planter le réseau!
N-Tron 1000 Series Hardware Guide 2-15
Installation Revised 2015-03-24
N-Tron 1000 Series Hardware Guide 2-16
Operation and Maintenance Revised 2015-03-24
Section 3 Operation and Maintenance
Introduction
The N-Tron 1000 Series Gigabit Media Converter & Industrial Gigabit Ethernet Switch devices provide operating status information through the LED indicators located on the front panel.
Controls and Indicators
Model 1002MC, 1003GX2, 1005TX Indicators
Table 8. Model 1002MC, 1003GX2, 1005TX Indicators (from top to bottom)
INDICATOR DESCRIPTION
LNK/ACT
SPD1000
N-Tron 1000 Series Hardware Guide 3-17
Green LED lights when power is connected
LED indicating link/activity
LED indicating 1000 Link data speed
Operation and Maintenance Revised 2015-03-24
Table 9 describes the indicator states and the operating modes:
Table 9. Model 1002MC, 1003GX2, 1005TX Indicator States
INDICATOR STATE DESCRIPTION
LNK/ACT
SPD1000
ON Power is applied
OFF Power is off
ON Link established, no activity on cable
BLINKING Link established, activity on cable
OFF No link activity on cable
ON Link is operating at 1000Mbps
OFF Link is operating at 10/100Mbps
Model 1008TX Indicators
Table 10. Model 1008TX Indicators (from top to bottom)
INDICATOR DESCRIPTION
Green LED lights when power is connected
ACT
1000
3-18
LED indicating activity
LED indicating 1000 Link data speed
N-Tron 1000 Series Hardware Guide
Operation and Maintenance Revised 2015-03-24
Table 11 describes the indicator states and the operating modes:
Table 11. Model 1008TX Indicator States
INDICATOR STATE DESCRIPTION
ACT
1000
ON Power is applied
OFF Power is off
ON/BLINKING Link established, activity on cable
OFF No link activity on cable
ON Link is operating at 1000Mbps
OFF Link is operating at 10/100Mbps
Maintenance
Maintenance is limited to verifying the cable interface and unit cleaning.
Verify/Troubleshoot Cable Interface
1. Make sure the (Power LED) is ON.
2. Make sure you are supplying sufficient current for the chosen switch version.
Note: The inrush current will exceed the steady state current by ~ 2X.
3. Verify that Link LEDs are ON for both ports.
4. Verify cabling used between stations.
5. Verify that cabling is Category 3 or greater for 10Mbps Operation.
Cleaning
Clean hardware only with a damp cloth.
N-Tron 1000 Series Hardware Guide 3-19
Operation and Maintenance Revised 2015-03-24
Red Lion Controls N-Tron 1000 Series Limited Warranty
Red Lion warrants to the end user that this hardware product will be free from defects in workmanship and materi­als, under normal use and service, for the applicable warranty period from the date of purchase from Red Lion or its authorized reseller. If a product does not operate as warranted during the applicable warranty period, Red Lion shall, at its option and expense, repair the defective product or part, deliver to customer an equivalent product or part to replace the defective item, or refund to customer the purchase price paid for the defective product. All prod­ucts that are replaced will become the property of Red Lion. Replacement products may be new or reconditioned. Any replaced or repaired product or part has a ninety (90) day warranty or the remainder of the initial warranty period, whichever is longer. Red Lion shall not be responsible for any custom software or firmware, configuration information, or memory data of customer contained in, stored on, or integrated with any products returned to Red Lion pursuant to any warranty.
OBTAINING WARRANTY SERVICE: Customer must contact Red Lion within the applicable warranty period to obtain warranty service authorization. Dated proof of purchase from Red Lion or its authorized reseller may be required. Products returned to Red Lion must be pre-authorized by Red Lion with a Return Material Authorization (RMA) number marked on the outside of the package, and sent prepaid and packaged appropriately for safe ship­ment. Responsibility for loss or damage does not transfer to Red Lion until the returned item is received by Red Lion. The repaired or replaced item will be shipped to the customer, at Red Lion's expense, not later than thirty (30) days after Red Lion receives the product. Red Lion shall not be responsible for any software, firmware, information, or memory date of customer contained in, stored on, or integrated with any products returned to Red Lion for repair, whether under warranty or not.
ADVANCE REPLACEMENT OPTION: Upon registration, this product qualifies for advance replacement. A replacement product will be shipped within three (3) days after verification by Red Lion that the product is consid­ered defective. The shipment of advance replacement products is subject to local legal requirements and may not be available in all locations. When an advance replacement is provided and customer fails to return the original product to Red Lion within fifteen (15) days after shipment of the replacement, Red Lion will charge customer for the replacement product, at list price.
WARRANTIES EXCLUSIVE: IF A RED LION PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUS­TOMER'S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT RED LION’S OPTION. TO THE FULL EXTENT ALLOWED BY LAW, THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, TERMS, OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES, TERMS, OR CONDITIONS OF MERCHANT­ABILITY, FITNESS FOR A PARTICULAR PURPOSE, SATISFACTORY QUALITY, CORRESPONDENCE WITH DESCRIPTION, AND NON-INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY DISCLAIMED. RED LION NEI­THER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. RED LION SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUS­TOMER'S OR ANY THIRD PERSON'S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAU­THORIZED ATTEMPTS TO OPEN, REPAIR OR MODIFY THE PRODUCT, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, POWER CUTS OR OUTAGES, OTHER HAZARDS, OR ACTS OF GOD.
LIMITATION OF LIABILITY: TO THE FULL EXTENT ALLOWED BY LAW, RED LION ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEG­LIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATA, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION,
3-20
N-Tron 1000 Series Hardware Guide
Operation and Maintenance Revised 2015-03-24
MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF N­TRON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT N-TRON'S OPTION. THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REM­EDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.
DISCLAIMER: Some countries, states, or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for personal injury, so the above limitations and exclusions may be limited in their application to you. When the implied warranties are not allowed to be excluded in their entirety, they will be limited to the duration of the applicable written warranty. This warranty gives you specific legal rights which may vary depending on local law.
GOVERNING LAW: This Limited Warranty shall be governed by the laws of the State of Delaware, U.S.A.
N-Tron 1000 Series Hardware Guide 3-21
Loading...