MODEL G307K2 - KADET 2 OPERATOR INTERFACE WITH 7" TFT DISPLAY
z CONFIGURED USING CRIMSON® 3 SOFTWARE
z THREE SERIAL COMMUNICATIONS PORTS
(1 RS-232 AND 2 RS-232/422/485 PORTS)
z 10 BASE-T/100 BASE-TX ETHERNET PORT COMMUNICATES
WITH UP TO FOUR PROTOCOLS SIMULTANEOUSLY
z UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE FLASH
MEMORY
z SD CARD SOCKET FOR LOADING DATABASE IN FIELD
z 7-INCH TFT LCD 32K COLOR 800 X 480 PIXEL DISPLAY
z NEMA 4/IP65 FRONT PANEL
z THREE FRONT PANEL LED INDICATORS
z POWER UNIT FROM 24 ±20% VDC
z RESISTIVE ANALOG TOUCHSCREEN
U
R
US LISTED
L
IND. CONT
22SV
GENERAL DESCRIPTION
The G307K2 is the perfect solution for applications that require the operator
to monitor and control more than just a single device. With three serial ports and
an Ethernet port, the 7" Kadet 2 can connect to multiple serial and Ethernet
devices simultaneously, including PLCs, motor drives, bar code scanners, etc.
The G307K2 performs the functions of a multiple protocol converter, using
three high-speed RS-232/422/485 communications ports and a 10 Base-T
Ethernet port. The Ethernet port supports up to four protocols simultaneously,
allowing dissimilar Ethernet based products to communicate with one another.
The SD card slot can be used to load the unit's configuration file, allowing
configuration changes to be made and saved to the card for later transfer.
The G3 Kadet 2 range of HMIs is programmed with Red Lion's free Crimson
3 software. Crimson offers easy to use drag and drop communications
configuration, while the embedded image library allows the programmer to
create intuitive screens and prompts for the operator.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use the controller to directly command motors, valves, or other
actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the unit.
CONTENTS OF PACKAGE
- G307K2 Operator Interface.
- Hardware packet for mounting unit into panel.
- Terminal block for connecting power.
- Spare fuse.
ORDERING INFORMATION
MODEL NO.DESCRIPTIONPART NUMBER
G307K27" TFT Operator InterfaceG307K200
SDSD Card
CBLCommunications Cables and Adaptor
G3FILMProtective FilmG3FILM7K
1
Contact your Red Lion distributor or visit our website for selection of SD
cards, adapters and cables.
Note: If replacing Model G306K000, see Tech Note TNG3K6.
1
1
SDxxxxxx
CBLxxxxx
CAUTION: Risk Of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
1
Page 2
sPecIfIcatIons
1. POWER REQUIREMENTS:
Must use Class 2 or SELV rated power supply.
Power connection via removable three position terminal block.
Supply Voltage: 24 VDC ±20%, Class 2
Maximum Power: 250 mA @ 24 VDC
Fuse: Fast-blow 800 mA, 5x20 mm
2. BATTERY: Lithium coin cell. Typical lifetime of 10 years.
On Board User Memory: 128 Mbyte of non-volatile Flash memory.
Memory Card: SD slot accepts standard capacity cards up to 2 Gbyte.
6. COMMUNICATIONS: Three Serial Ports - One RS-232 port, two
RS-232/422/485: One Ethernet Port
Serial Ports: Format and Baud Rates for each port are individually software
programmable up to 115,200 baud.
2
DIMENSIONS In inches (mm)
7.888 (200.35)
COM CPU PWR
7.476 (189.9)
Ethernet Port: 10/100 Mbps
7. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range: 0 to 45°C
Operating and Storage Humidity: 10-90% relative humidity (non-
condensing) from -20 to 60°C.
Vibration: Operational 10 to 25 Hz, in X, Y, Z direction, 30 minutes, 2 g’s.
8. CERTIFICATIONS AND COMPLIANCES:
SAFETY
UL Listed, File #E302106, UL508
UL Type 4 Indoor Use Only Enclosure rating (Face only), UL50
10. CONSTRUCTION: Plastic enclosure with NEMA 4/IP65 front panel when
properly installed.
11. WEIGHT: 30 oz. (850 g)
1.675 (42.55)
5.762
(146.35)
VESA Mount: VESA 75 (75 mm x 75 mm). Use four screws (M4-0.7 mm) less than 8 mm long.
5.350
(135.9)
InstallIngand PowerIngthe g307K2
MOUNTING INSTRUCTIONS
The unit can be mounted into enclosures with a depth of 4". It is recommended
that the unit be mounted on the front panel of a steel enclosure. Allow clearance
of 1" around the sides of the unit for the mounting hardware. Allow 2.5" along
the bottom edge if using Red Lion communication cables.
Place the unit in the panel cutout. Slide clamps into the four holes provided
at the top and bottom of the case. Tighten the clamping screws in an even pattern
until the unit is secured in the panel. Caution: Do not over tighten the clamps.
To seal to NEMA4 specifications, all supplied mounting clamps must be used.
(Torque is 2.6 – 3.5 in/lb.) The panel must not flex more than 0.010".
R.08 (R2)
7.56 (192)
5.43 (138)
2
Page 3
CONNECTING POWER
A
The G307K2 requires a 24 VDC ±20% power supply. Please take care to
observe the following points:
- The wire used to connect the operator interface’s power supply should
be at least 22-gage wire. If a longer cable run is used, a heavier gage
wire should be used. The routing of the cable should be kept away from
large contactors, inverters, and other devices which may generate
significant electrical noise.
- A power supply with a Class 2 or SELV rating is to be used. A Class 2 or
SELV power supply provides isolation to accessible circuits from
hazardous voltage levels generated by a mains power supply due to
single faults. SELV is an acronym for “safety extra-low voltage.”
Safety extra-low voltage circuits shall exhibit voltages safe to touch
both under normal operating conditions and after a single fault, such as
a breakdown of a layer of basic insulation or after the failure of a single
component has occurred.
communIcatIng wIththe g307K2
The G307K2 has three serial ports, as well as an Ethernet port. The serial
ports are exposed via one DB9 male connector, and one DB9 female connector.
You may assign one unique protocol to each of the ports for a total of three
different serial protocols.
Note: If you assign a protocol to the Programming Port, you will no longer
be able to download. You should create a means to call the StopSystem()
function from the HMI touchscreen, such that the Programming Port activity
can be halted on command. Alternatively, the HMI's memory can be cleared to
restore download functionality.
The Ethernet port can be programmed to communicate via four protocols
simultaneously. For more information on protocol support, please refer to the
Crimson 3 programming software.
RJ-45 Ethernet
PROGRAMMING/COM2
5
COMM
TX 4
3
2
1
9
8
7
6 RX
RS-232
DB9-M
PC CONNECTION
Configuration files are downloaded to the Kadet 2 via the PC port, which can
be connected to a computer via various cables.
COM1
1
RXA
2
RXB
3
4
COMM
5
RS-485 (2-wire)
DB9-F
COM3
1
2
3
4
5
COMM
RS-232
DB9-F
1
RXA
RXB
TXA
TXB
COMM
2
3
4
5
6
7
8
9
6
7
8
9
RS-485 (4-wire)
DB9-F
1
COMM
2
3
4
5
6
7
RX
8
TX
9
COMM
RX
6
7
8
9
TX
RX
RXB
5
4
3
2
1
RS-232
DB9-M
9
CTS8
7
RTS
6
RS-485
DB9-F
USB to Serial
PT# CBLUSB7K (includes CBLPRO7K)
3
Cable
PT# CBLPRO7K
Page 4
DEVICE COMMUNICATIONS
Several adapters are available which allow direct connection via
Red Lion communications cables. For a list of adapters and cables,
please visit http://www.redlion.net/support/downloads.html.
G3 Comms Cable
PT# CBLxxxxx
Kadet Adapter
PT# CBLADKxx
SLC 5/03 CPU
FORCE
RUN
DH485
FLT
RS232
BATT
RUN
PROG
REM
PWR OUT +24
PWR OUT COM
120/240 VAC
VAC NEUT
CHASSIS GND
settIngthe swItches
ON
1
43
2
Normal mode.
software/unIt oPeratIon
CRIMSON SOFTWARE
Crimson software is available as a free download from Red Lion’s website or
it can be purchased on a CD, see “Ordering Information” for part number. The
latest version of the software is always available from the website, and updating
your copy is free.
TOUCHSCREEN
The unit will only produce an audible tone (beep) when a touch on an active
touchscreen cell is sensed. The touchscreen is fully functional as soon as the
operator interface is initialized, and can be operated with gloved hands.
POWER
VDC
USER
POWER
ON
Cycle power with the switches as shown in order
to display the Clear Database prompt. Touch the left
side of the display to clear the database; touch the
1
3 4
2
right side to continue in normal mode.
This operator interface utilizes a resistive analog touchscreen for user input.
FRONT PANEL LEDS
There are three front panel LEDs. Shown below is the default status of
the LEDs.
LEDINDICATION
RED (COM)
FLASHING Communications are active.
GREEN (CPU)
STEADYCPU is functioning
ORANGE (PWR)
STEADYPower is applied.
BATTERY REPLACEMENT
The G307K2 uses one CR2032 coin type lithium battery to maintain the RTC
(real-time clock) and for proper Ethernet download operation. To change the
battery, remove power, cabling, and then the rear cover of the unit. Remove the
old battery from the holder and replace with a new battery*. Replace the rear
cover, cables, and re-apply power. Set the RTC to the proper date and time.
* Please note that the old battery must be disposed of in a manner that
complies with your local waste regulations. Also, the battery must not be
disposed of in fire, or in a manner whereby it may be damaged and its contents
come into comtact with human skin.
TROUBLESHOOTING YOUR G307K2
If for any reason you have trouble operating, connecting, or simply have
questions concerning your new G307K2, contact Red Lion’s technical support.
For contact information, refer to the front page of this bulletin for phone and
fax numbers.
EMAIL: techsupport@redlion.net
Web Site: http://www.redlion.net
CAUTION: The circuit board contains static sensitive
components. Before handling the operator interface without the
rear cover attached, discharge static charges from your body by
touching a grounded bare metal object. Ideally, handle the
operator interface at a static controlled clean workstation. Also,
do not touch the surface areas of the circuit board. Dirt, oil, or
other contaminants may adversely affect circuit operation.
CAUTION: Danger of explosion if battery is incorrectly
replaced. Replace only with the same or equivalent type
recommended by the manufacturer. Dispose of used batteries
according to the manufacturer’s instructions.
Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
Red Lion Controls
Europe
Softwareweg 9
NL - 3821 BN Amersfoort
Tel +31 (0) 334 723 225
Fax +31 (0) 334 893 793
Red Lion Controls
India
201-B, 2nd Floor, Park Centra
Opp 32 Mile Stone, Sector-30
Gurgaon-122002 Haryana, India
Tel +91 984 487 0503
4
Red Lion Controls
China
Unit 302, XinAn Plaza
Building 13, No.99 Tianzhou Road
ShangHai, P.R. China 200223
Tel +86 21 6113 3688
Fax +86 21 6113 3683
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.