MODEL G303 - GRAPHIC LCD OPERATOR INTERFACE TERMINALS
CONFIGURED USING CRIMSON 2.0 SOFTWARE
UP TO 5 RS-232/422/485 COMMUNICATIONS PORTS
(2 RS-232 AND 1 RS-422/485 ON BOARD, 1 RS-232 AND 1 RS422/485 ON OPTIONAL COMMUNICATIONS CARD)
10 BASE T/100 BASE-TX ETHERNET PORT TO NETWORK
UNITS AND HOST WEB PAGES
USB PORT TO DOWNLOAD THE UNIT’S CONFIGURATION
FROM A PC OR FOR DATA TRANSFERS TO A PC
UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE
MEMORY (4 MBYTE FLASH)
COMPACTFLASH® SOCKET TO INCREASE MEMORY CAPACITY
3.2-INCH 128X64 PIXEL LCD WITH YELLOW LED BACKLIGHT,
ABLE TO SUPPORT TEXT AND SIMPLE GRAPHICS
OUTDOOR UNIT WITH UV RATED OVERLAY AVAILABLE
32 BUTTON KEYPAD WITH USER IDENTIFIABLE KEYS,
NAVIGATIONAL KEYS, NUMERIC KEYS, KEYS FOR ON-SCREEN MENUS, AND OTHER VARIOUS KEYS.
THREE FRONT PANEL LEDS
POWER UNIT FROM 24 VDC ±20% SUPPLY
U
R
C
LABORATORY EQUIPMENT
US LISTED
L
63YN
FOR USE IN HAZARDOUS LOCATIONS:
Class I, Division 2, Groups A, B, C, and D Class II, Division 2, Groups F and G Class III, Division 2
Bulletin No. G303-N
Drawing No. LP0561
Released 11/13
GENERAL DESCRIPTION
The G303 Operator Interface Terminal combines unique capabilities normally expected from high-end units with a very affordable price. It is built around a high performance core with integrated functionality. This core allows the G303 to perform many of the normal features of the Paradigm range of Operator Interfaces while improving and adding new features.
The G303 is able to communicate with many different types of hardware using high-speed RS232/422/485 communications ports and Ethernet 10 Base T/100 Base-TX communications. In addition, the G303 features USB for fast downloads of configuration files and access to trending and data logging. A CompactFlash socket is provided so that Flash cards can be used to collect your trending and data logging information as well as to store larger configuration files.
In addition to accessing and controlling of external resources, the G303 allows a user to easily view and enter information. The unit uses a Liquid Crystal Display (LCD) module, which is easily readable in both indoor and outdoor applications. Users can enter data through the front panel 32-button keypad that has user identifiable keys.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Do not use the controller to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the controller.
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2/CLASS II, DIVISION 2/CLASS III, DIVISION 2
CAUTION: Risk of Danger.
Read complete instructions prior to installation
and operation of the unit.
CompactFlash is a registered trademark of CompactFlash Association.
CONTENTS OF PACKAGE
- G303 Operator Interface.
- Panel gasket.
- Two user legendable key sheets.
- Template for panel cutout.
- Hardware packet for mounting unit into panel.
- Terminal Block for connecting power.
ORDERING INFORMATION
MODEL NO. DESCRIPTION PART NUMBER
G303
G3CF CompactFlash Card G3RS RS232/485 Optional Communication Card G3RS0000 G3CN CANopen Optional Communication Card G3CN0000
G3DN
G3GSM GSM/GPRS Modem Option Card
G3PBDP Profibus DP Optional Communication Card G3PBDP00
SFCRM2 Crimson 2.0
CBL
G3FILM Protective Films G3FILM03
1
Contact your Red Lion distributor or visit our website for complete selection.
2
Use this part number to purchase Crimson on CD with a printed
manual, USB cable, and RS-232 cable. Otherwise, download from www. redlion.net.
3
Antenna (G3QANT00) is NOT included with the card. Must be purchased
separately if needed.
4
Red Lion offers RJ modular jack adapters. Refer to the DR literature for
complete details.
5
Battery type is lithium coin type CR2025.
6
Industrial grade two million write cycles. SMART Modular Technologies model
SG9CF (UL Listed Directory Category NWGQ)
Operator Interface for indoor applications only, textured finish with embossed keys
Operator Interface for indoor or outdoor applications, glossy finish with UV rated overlay (keys are not embossed)
DeviceNet Option Card With Isolated High Speed Communications Ports
RS-232 Programming Cable CBLPROG0 USB Cable CBLUSB00 Communications Cables
DR DIN Rail Mountable Adapter Products
Replacement Battery Key Strip Paper LBAFLM02
6
3
2
1
4
5
G303M000
G303S000
G3CFxxxx
G3DN0000
G3GSM000
SFCRM200
CBLxxxxx DRxxxxxx
BNL20000
1
SpecificationS
1. POWER REQUIREMENTS: +24 VDC ±20% @ 9.5 W maximum. Must use a Class 2 circuit according to National Electrical Code (NEC),
NFPA-70 or Canadian Electrical Code (CEC), Part I, C22.1 or a Limited Power Supply (LPS) according to IEC 60950-1 or Limited-energy circuit according to IEC 61010-1.
Power connection via removable three position terminal block.
Notes:
1. The front panel PWR LED indicates power.
2. The G303’s circuit common is not connected to the enclosure of the unit. See “Connecting to Earth Ground” in the section “Installing and Powering the G303”.
2. BATTERY: Lithium coin cell. Typical lifetime of 10 years.
3. DISPLAY: 3.2" 128 x 64 pixel FSTN LCD with yellow LED backlight for characters and simple graphics applications.
4. 32-KEY KEYPAD: 8 user legendable keys, 5 navigational keys, 10+2 numeric keys, 4 dedicated keys, and 3 soft keys for on-screen menus.
5. MEMORY:
On Board User Memory: 4 Mbyte of onboard non-volatile Flash memory. Memory Card: CompactFlash Type II slot for Type I and Type II
CompactFlash cards.
6. COMMUNICATIONS: USB Port: Adheres to USB specification 1.1. Device only using Type B
connection.
WARNING - DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION.
Serial Ports: Format and Baud Rates for each port are individually software
programmable up to 115,200 baud. PGM Port: RS232 port via RJ12. COMMS Ports: RS422/485 port via RJ45, and RS232 port via RJ12. These
two ports share the same hardware; the G303 multiplexes the ports to communicate via two protocols. These ports may be used to configure different master protocols, but only one port may be used if configuring a slave protocol or AB DH485.
DH485 TXEN: Transmit enable; open collector, VOH = 15 VDC, VOL = 0.5
V @ 25 mA max.
Note: For additional information on the communications or signal
common and connections to earth ground please see “Connecting to Earth Ground” in the section “Installing and Powering the G303”.
Ethernet Port: 10 BASE-T / 100 BASE-TX
RJ45 jack is wired as a NIC (Network Interface Card).
7. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range: 0 to 50°C Storage Temperature Range: -30 to 70°C Operating and Storage Humidity: 80% maximum relative humidity (non-
condensing) from 0 to 50°C.
Vibration to IEC 68-2-6: Operational 5 to 500 Hz, 3 g. Shock to IEC 68-2-27: Operational 40 g Altitude: Up to 2000 meters.
8. CERTIFICATIONS AND COMPLIANCES:
SAFETY CE Approved
EN 61326-1 Immunity to Industrial Locations Emission CISPR 11 Class B IEC/EN 61010-1
RoHS Compliant UL Listed: File #E179259 UL Hazardous: File #E211967 Type 4X Enclosure rating (Face only) IP66 Enclosure rating (Face only) IP20 Enclosure rating (Rear of unit)
9. CONNECTIONS: Compression cage-clamp terminal block. Wire Gage: 12-30 AWG copper wire Torque: 5-7 inch-pounds (56-79 N-cm)
10. CONSTRUCTION: Steel rear metal enclosure with NEMA 4X/IP66 aluminum front plate when correctly fitted with the gasket provided. Installation Category I, Pollution Degree 2.
11. MOUNTING REQUIREMENTS: Maximum panel thickness is 0.25" (6.3 mm). For NEMA 4X/IP66 sealing, a steel panel with a minimum thickness of
0.125" (3.17 mm) is recommended. Maximum Mounting Stud Torque: 17 inch-pounds (1.92 N-m)
12. WEIGHT: 1.96 lbs (0.89 Kg)
DIMENSIONS In inches (mm)
7.45 (189.2)
5.85
(148.6)
2.1 (52)
6.04 (153.4)
4.44
(112.8)
2
inStalling and powering the g303
USER IDENTIFIABLE KEYS
The G303 unit comes with a pre-printed key strip inserted. This key strip is
labeled F1 through F8 and corresponds to Crimson software.
If desired, these keys may be custom labeled for specific functions. The default key strip may be removed and a custom key strip inserted. Each unit is delivered with two sheets of white “Cover 65” paper. This 8½ x11 paper may be used with most copiers, jet printers, or laser printers.
REMOVE PANEL GASKET BEFORE REMOVING OR INSERTING KEY STRIPS
Custom key strips are made easily using the Adobe Acrobat file available from www.redlion.net or included with each Crimson CD. This program allows users to enter custom text and color schemes.
If more customization is needed, a graphics package can be used. The key strip dimensions are as follows.
1.075
(27.3)
.675
(17.1)
4.00 (101.6)
3.00 (76.2)
3X .75
.325 (8.3)
.375 (9.5)
.375 (9.5)
1.40 .55
(35.6)
(14)
VISIBLE AREA OF
EIGHT KEYS
CHAMFER (2 PLCS)
FOR EASIER INSERTION
(14)
.55
R.100
When inserting the key strip into the slot in the G303 panel, start one corner
first then slowly insert the strip into place.
Note: Key strips need to be inserted into the unit before mounting into a
panel.
MOUNTING INSTRUCTIONS
This operator interface is designed for through-panel mounting. A panel cut­out diagram and a template are provided. Care should be taken to remove any loose material from the mounting cut-out to prevent that material from falling into the operator interface during installation. A gasket is provided to enable sealing to NEMA 4X/IP66 specification. Install the eight kep nuts provided and tighten evenly for uniform gasket compression.
Note: tightening the kep nuts beyond a maximum of 17 inch-pounds (1.92 N-m) may cause damage to the front panel.
6.875 (174.6)
6.25 (158.8)
8X Ø.188 (Ø4.8)
ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING DIVISION 2 WIRING METHODS AS SPECIFIED IN ARTICLE 501-4 (b), 502-4 (b), AND 503-3 (b) OF THE NATIONAL ELECTRICAL CODE, NFPA 70 FOR INSTALLATION WITHIN THE UNITED STATES, OR AS SPECIFIED IN SECTION 19-152 OF CANADIAN ELECTRICAL CODE FOR INSTALLATION IN CANADA.
CONNECTING TO EARTH GROUND
Each G303 has a chassis ground terminal on the back of the unit. Your unit
should be connected to earth ground (protective earth).
The chassis ground is not connected to signal common of the unit. Maintaining isolation between earth ground and signal common is not required to operate your unit. But, other equipment connected to this unit may require isolation between signal common and earth ground. To maintain isolation
between signal common and earth ground care must be taken when connections are made to the unit. For example, a power supply with isolation between its
signal common and earth ground must be used. Also, plugging in a USB cable may connect signal common and earth ground.
1
1. USB’s shield may be connected to earth ground at the host. USB’s shield in
turn may also be connected to signal common.
POWER SUPPLY REQUIREMENTS
The G303 requires a 24 VDC power supply rated at 9.5 W. Your unit may draw considerably less than 9.5 W depending upon the options being used. As additional features are used your unit will draw increasing amounts of power. Items that could cause increases in current are additional communications, optional communications card, Compact Flash card, and other features programmed through Crimson.
In any case, it is very important that the power supply is mounted correctly if the unit is to operate reliably. Please take care to observe the following points:
– The power supply must be mounted close to the unit, with usually not
more than 6 feet (1.8 m) of cable between the supply and the operator interface. Ideally, the shortest length possible should be used.
– The wire used to connect the operator interface’s power supply should
be at least 22-gage wire. If a longer cable run is used, a heavier gage wire should be used. The routing of the cable should be kept away from large contactors, inverters, and other devices which may generate significant electrical noise.
– A power supply with a Class 2 or SELV rating is to be used. A Class 2
or SELV power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults. SELV is an acronym for “safety extra-low voltage.” Safety extra-low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault, such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred.
All tolerances ±0.010" (±0.25 mm).
5.275 (134)