Red Lion ET-8ES-MIL-1, ET-8MS-MIL-1 Users Manual

IP67
Fast
Industrial
Switch
Contents at a Glance:
Section 1
General Specifications
Page 3
Section 2
LED Indicators
Page 5
Section 3
Mechanical Dimensions\Installation
Page 6
Section 4
Power and Communication Wiring
Page 7
Section 5
Mating Connections Wiring
Page 8
Section 6
Service Information
Page 9
USER MANUAL
Installation and Wiring Manual
This manual applies to the following products:
ET-8ES-MIL-1 8-port unmanaged IP67 Ethernet switch with 8 10/100 ports ET-8MS-MIL-1 8-port managed IP67 Ethernet switch with 8 10/100 ports
ET-8xS-MIL_manual r07.doc Page 1 of 9 Last Revised: 16-Jan-14
RED LION Protected Technology Policy - Red Lion protects your investment in Red Lion systems
Note: All information in this document is subject to change without notice.
with long-term planned technology and our unique Protected Technology Policy. We will continue to support the specified capabilities of standard Red Lion products for at least five years (twenty years for Industrial Managed Switches). We plan each product improvement and new feature to be upward compatible with existing designs and installations. Our goals are to make each new software release bring new power to your Red Lion systems and have every existing feature, applications program and data file continue to work. We protect your investment even further with a liberal five-year trade-in policy. Exchange standard products for upgraded versions of the same product to take advantage of new features and performance improvements at any time for five years. A prorated trade-in allowance will be given for your existing equipment. Red Lion protects your long-term productivity with state-of-the-art planned technology and continued support.
Red Lion Statement of Limited Warranty - Red Lion, manufacturer of Red Lion products, warrants to
Buyer that products, except software, manufactured by Red Lion will be free from defects in material and workmanship. Red Lion's obligation under this warranty will be limited to repairing or replacing, at Red Lion's option, the defective parts within five (5) years of the date of installation, or within 60 months of the date of shipment from the point of manufacture, whichever is sooner. Products may be returned by Buyer only after permission has been obtained from Red Lion. Buyer will prepay all freight charges to return any products to the repair facility designated by Red Lion. This limited warranty does not cover losses or damages which occur in shipment to or from Buyer or due to improper installation, maintenance, misuse, neglect or any cause other than ordinary commercial or industrial applications. In particular, Red Lion makes no warranties whatsoever with respect to implied warranties of merchantability or fitness for any particular purpose. All such warranties are hereby expressly disclaimed. No oral or written information or advice given by Red Lion or Red Lion’s representative shall create a warranty or in any way increase the scope of this warranty. This limited warranty is in lieu of all other warranties whether oral or written, expressed or implied. Red Lion's liability shall not exceed the price of the individual units, which are the basis of the claim. In no event shall Red Lion be liable for any loss of profits, loss of use of facilities or equipment, or other indirect, incidental or consequential damages.
INSTALLATION AND HAZARDOUS AREA WARNINGS - These products should not be used
to replace proper safety interlocking. No software-based device (or any other solid-state device) should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety. In particular, Red Lion disclaims any responsibility for damages, either direct or consequential, that result from the use of this equipment in any application. All power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods and in accordance with the authority having jurisdiction.
FCC Statement - This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; Consult the dealer or an experienced radio/TV technician for help.
Copyright & Trademarks - Copyright 2013 Sixnet, Inc. All Rights Reserved.
ET-8xS-MIL_manual r07.doc Page 2 of 9 Last Revised: 16-Jan-14
Section 1
General Specifications
Overview
This manual will help you install and maintain the IP67 Industrial Ethernet Switch. Installation of these switches will enable the user to manage the network by monitoring/gathering network data, allow for browser or telnet configuration, increase network performance, and more.
Note: This manual only covers the installation and wiring of these switches. Refer
to the separate Software User Manual for details on configuring and using any of
the management functions such as SNMP, RSTP, IGMP, port mirroring, etc.
Operation
The IP67 Industrial Ethernet Switch can support 10BaseT (10 Mbps) or 100BaseT (100 Mbps) on all ports. Each of these ports will independently auto-sense the speed, allowing you to interface to regular(10Mb) or fast Ethernet(100Mb) devices.
Standards and Specs
The IP67 Industrial Ethernet Switch meets the following standards plus others:
General
8 Fast Ethernet ports
Ethernet switch type
Managed or Unmanaged
Ethernet protocols supported
All IEEE 802.3
Ethernet connectors
MIL-DTL-38999 Series III w/ 22D socket (female) contacts (9-
35)
USB/RS232 connector
MIL-DTL-38999 Series III w/ 22D socket (female) contacts (9-
35)
Ethernet speed (10/100BaseTX)
Auto-negotiation (10 or 100 Mbps)
Ethernet MDI/MDIX
Auto-crossover
Ethernet TD and RD polarity
Auto-polarity
Ethernet isolation
1500 VRMS 1 minute
Latency for 10 Mbps ports
16us
Typical less frame time
(Varies on load & settings)
Latency for 100 Mbps ports
5us
Full or half duplex operation
Yes, automatic on unmanaged, configurable on managed
MAC addresses supported
2048
Memory bandwidth
3.2 Gbps
Power
Automatic power savings when ports are unused
Power input receptacle
MIL-DTL-38999 Series III w/ pin (male) contacts (9-98) size 20
Input voltage (all models)
10-30 VDC (continuous)
Input power (typical – with all ports linked and active)
3 W (unmanaged) 4 W (managed)
Reverse polarity protection
Yes
Extended power protection
Exceeds MIL-STD-1275
Surge protection
100 volts for 1 second
Transient protection
15,000 watts peak
Spike Protection
5,000 watts (10x for 10 uS) or 250 volts (50x for 100 uS)
Environmental
Truly industrial design
Operating temperature range
-40 to +75 °C (cold startup at -40 °C)
Storage temperature range
-40 to +85 °C
Humidity (non-condensing)
5 to 95% RH (Conformal coating avaible by special order)
Vibration, shock and freefall
MIL-STD-810F; IEC68-2-6, -27 and -32
Electrical safety
UL508/CSA C22, EN61010-1
EMC emissions and immunity
MIL-STD-461E; FCC part 15, ICES-003; EN55022, IEC61326-1
Hazardous locations (Class I, Division 2; Zone 2)
ANSI / ISA 12.12.01, CSA C22.2/213; ATEX IEC60079-0, 15
Package protection
IP67 dust, oil and water-tight
Dimensions (L x W x H) (see diagram on next page)
10.5 x 4 x 1.5” (267 x 102 x 38 mm)
Weight (including caps)
2.20 lbs (1 Kg)
ET-8xS-MIL_manual r07.doc Page 3 of 9 Last Revised: 16-Jan-14