Red Lion ET-8ES-MIL-1, ET-8MS-MIL-1 Users Manual

IP67
Fast
Industrial
Switch
Contents at a Glance:
Section 1
General Specifications
Page 3
Section 2
LED Indicators
Page 5
Section 3
Mechanical Dimensions\Installation
Page 6
Section 4
Power and Communication Wiring
Page 7
Section 5
Mating Connections Wiring
Page 8
Section 6
Service Information
Page 9
USER MANUAL
Installation and Wiring Manual
This manual applies to the following products:
ET-8ES-MIL-1 8-port unmanaged IP67 Ethernet switch with 8 10/100 ports ET-8MS-MIL-1 8-port managed IP67 Ethernet switch with 8 10/100 ports
ET-8xS-MIL_manual r07.doc Page 1 of 9 Last Revised: 16-Jan-14
RED LION Protected Technology Policy - Red Lion protects your investment in Red Lion systems
Note: All information in this document is subject to change without notice.
with long-term planned technology and our unique Protected Technology Policy. We will continue to support the specified capabilities of standard Red Lion products for at least five years (twenty years for Industrial Managed Switches). We plan each product improvement and new feature to be upward compatible with existing designs and installations. Our goals are to make each new software release bring new power to your Red Lion systems and have every existing feature, applications program and data file continue to work. We protect your investment even further with a liberal five-year trade-in policy. Exchange standard products for upgraded versions of the same product to take advantage of new features and performance improvements at any time for five years. A prorated trade-in allowance will be given for your existing equipment. Red Lion protects your long-term productivity with state-of-the-art planned technology and continued support.
Red Lion Statement of Limited Warranty - Red Lion, manufacturer of Red Lion products, warrants to
Buyer that products, except software, manufactured by Red Lion will be free from defects in material and workmanship. Red Lion's obligation under this warranty will be limited to repairing or replacing, at Red Lion's option, the defective parts within five (5) years of the date of installation, or within 60 months of the date of shipment from the point of manufacture, whichever is sooner. Products may be returned by Buyer only after permission has been obtained from Red Lion. Buyer will prepay all freight charges to return any products to the repair facility designated by Red Lion. This limited warranty does not cover losses or damages which occur in shipment to or from Buyer or due to improper installation, maintenance, misuse, neglect or any cause other than ordinary commercial or industrial applications. In particular, Red Lion makes no warranties whatsoever with respect to implied warranties of merchantability or fitness for any particular purpose. All such warranties are hereby expressly disclaimed. No oral or written information or advice given by Red Lion or Red Lion’s representative shall create a warranty or in any way increase the scope of this warranty. This limited warranty is in lieu of all other warranties whether oral or written, expressed or implied. Red Lion's liability shall not exceed the price of the individual units, which are the basis of the claim. In no event shall Red Lion be liable for any loss of profits, loss of use of facilities or equipment, or other indirect, incidental or consequential damages.
INSTALLATION AND HAZARDOUS AREA WARNINGS - These products should not be used
to replace proper safety interlocking. No software-based device (or any other solid-state device) should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety. In particular, Red Lion disclaims any responsibility for damages, either direct or consequential, that result from the use of this equipment in any application. All power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods and in accordance with the authority having jurisdiction.
FCC Statement - This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; Consult the dealer or an experienced radio/TV technician for help.
Copyright & Trademarks - Copyright 2013 Sixnet, Inc. All Rights Reserved.
ET-8xS-MIL_manual r07.doc Page 2 of 9 Last Revised: 16-Jan-14
Section 1
General Specifications
Overview
This manual will help you install and maintain the IP67 Industrial Ethernet Switch. Installation of these switches will enable the user to manage the network by monitoring/gathering network data, allow for browser or telnet configuration, increase network performance, and more.
Note: This manual only covers the installation and wiring of these switches. Refer
to the separate Software User Manual for details on configuring and using any of
the management functions such as SNMP, RSTP, IGMP, port mirroring, etc.
Operation
The IP67 Industrial Ethernet Switch can support 10BaseT (10 Mbps) or 100BaseT (100 Mbps) on all ports. Each of these ports will independently auto-sense the speed, allowing you to interface to regular(10Mb) or fast Ethernet(100Mb) devices.
Standards and Specs
The IP67 Industrial Ethernet Switch meets the following standards plus others:
General
8 Fast Ethernet ports
Ethernet switch type
Managed or Unmanaged
Ethernet protocols supported
All IEEE 802.3
Ethernet connectors
MIL-DTL-38999 Series III w/ 22D socket (female) contacts (9-
35)
USB/RS232 connector
MIL-DTL-38999 Series III w/ 22D socket (female) contacts (9-
35)
Ethernet speed (10/100BaseTX)
Auto-negotiation (10 or 100 Mbps)
Ethernet MDI/MDIX
Auto-crossover
Ethernet TD and RD polarity
Auto-polarity
Ethernet isolation
1500 VRMS 1 minute
Latency for 10 Mbps ports
16us
Typical less frame time
(Varies on load & settings)
Latency for 100 Mbps ports
5us
Full or half duplex operation
Yes, automatic on unmanaged, configurable on managed
MAC addresses supported
2048
Memory bandwidth
3.2 Gbps
Power
Automatic power savings when ports are unused
Power input receptacle
MIL-DTL-38999 Series III w/ pin (male) contacts (9-98) size 20
Input voltage (all models)
10-30 VDC (continuous)
Input power (typical – with all ports linked and active)
3 W (unmanaged) 4 W (managed)
Reverse polarity protection
Yes
Extended power protection
Exceeds MIL-STD-1275
Surge protection
100 volts for 1 second
Transient protection
15,000 watts peak
Spike Protection
5,000 watts (10x for 10 uS) or 250 volts (50x for 100 uS)
Environmental
Truly industrial design
Operating temperature range
-40 to +75 °C (cold startup at -40 °C)
Storage temperature range
-40 to +85 °C
Humidity (non-condensing)
5 to 95% RH (Conformal coating avaible by special order)
Vibration, shock and freefall
MIL-STD-810F; IEC68-2-6, -27 and -32
Electrical safety
UL508/CSA C22, EN61010-1
EMC emissions and immunity
MIL-STD-461E; FCC part 15, ICES-003; EN55022, IEC61326-1
Hazardous locations (Class I, Division 2; Zone 2)
ANSI / ISA 12.12.01, CSA C22.2/213; ATEX IEC60079-0, 15
Package protection
IP67 dust, oil and water-tight
Dimensions (L x W x H) (see diagram on next page)
10.5 x 4 x 1.5” (267 x 102 x 38 mm)
Weight (including caps)
2.20 lbs (1 Kg)
ET-8xS-MIL_manual r07.doc Page 3 of 9 Last Revised: 16-Jan-14
Military Standards Compliance
MIL Standard
Specification
Description
MIL-STD-810F; 501.4, I;
501.4, II
+70°C Transport/Storage
High Temperature
+65°C operating
MIL-STD-810F; 502.4, I;
501.4, II
-20°C Transport/Storage
Low Temperature
-10°C operation
MIL-STD-810F; 507.4
95%
Humidity
MIL-STD-810F; 500.4, II
9000 Feet
Low pressure operating
MIL-STD-810F; 500.4, I
15000 Feet
Low pressure transportation
MIL-STD-810F; 514
5-1000 Hz
Vibration
MIL-STD-810F; 516, I
half sinus 40g 11msec
Mechanical Shock
MIL-STD-810F; 516, V
Drop on table
Handling Shock
MIL-STD-810F; 509
5% salt for 48 hours
Salt
MIL-STD-810F; 510, I
According to specs
Sand and Dust
MIL-STD-810F, Method 514.5
Vibration while in transport
MIL-STD-810F, Method 512.4
Immersion into water; rain and wind resistance
MIL-STD-1275B
100V for 1 second 15,000 watts peak
250V (50 times for 100uS)
Surge Protection
Transient Voltage
Spike Protection
MIL-STD-461E-RE102
2MHz to 18GHz
Radiated emissions(ground)
MIL-STD-461E-RS103
2MHz to 18GHz
Radiated susceptibility
Safety Warnings
Strictly abiding by these warnings will help ensure the safe installation, startup and operation of the switch.
INSTALL THE SWITCH IN ACCORDANCE WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES.
LIGHTNING DANGER: DO NOT WORK ON EQUIPMENT DURING PERIODS OF LIGHTNING ACTIVITY.
WARNING
(EXPLOSION
HAZARD)
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2 (ZONE 2).
WARNING
(EXPLOSION
HAZARD)
WHEN IN HAZARDOUS LOCATIONS, DISCONNECT POWER BEFORE REPLACING OR WIRING UNITS.
WARNING
(EXPLOSION
HAZARD)
DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.
Consignes de Sécurité
Le strict respect de ces avertissements contribuera à assurer la sécurité de l'installation, le démarrage et le fonctionnement de l'interrupteur.
INSTALLEZ L’APPAREIL CONFORMÉMENT AUX CODES ÉLECTRIQUES LOCAUX ET NATIONAUX.
DANGER DE FOUDRE: NE PAS TRAVAILLER SUR L’ÉQUIPEMENT PENDANT LES PÉRIODES D’ACTIVITÉS DE FOUDRE.
AVERTISSEMENT
(RISQUE
D’EXPLOSION)
LA SUBSTITUTION DE TOUT COMPOSANT PEUT NUIRE À LA CONFORMITÉ DE CLASSE I, DIVISION 2 (ZONE 2).
AVERTISSEMENT
(RISQUE
D’EXPLOSION)
LORSQUE DANS DES ENDROITS DANGEREUX, DÉBRANCHEZ LE CORDON D’ALIMENTATION AVANT DE REMPLACER OU DE BRANCHER DES MODULES.
AVERTISSEMENT
(RISQUE
D’EXPLOSION)
NE DÉBRANCHEZ PAS L’ÉQUIPEMENT PENDANT QUE LE CIRCUIT EST DIRECT OU À MOINS
QUE L’ENVIRONNEMENT SOIT CONNU POUR ÊTRE LIBRE DE CONCENTRATIONS
INFLAMMABLES.
ET-8xS-MIL_manual r07.doc Page 4 of 9 Last Revised: 16-Jan-14
Section 2
LED Indicators
Overview
The IP67 Industrial Ethernet switches have communication LEDs for each port, an “OK” output LED, a status LED and power LEDs. Refer to the sample pictures below for the location of these LEDs.
LED Locations
Status LED
The Status LED indicates the overall health of the switch. It is normally ON solid indicating that no internal CPU or software problems are detected. It will flash when loading firmware and briefly on power up or reset. Otherwise, if it is OFF or flashing for an extended period of time then a problem is detected. In this case, please contact your switch supplier for support.
Power LEDs
There is a power LED labeled as Power. It will be on solid when power is applied to the switch.
LNK LED
The port LEDs are multifunctional and indicate link confirmation, activity, and speed.
Flashing = Indicates that there is a proper Ethernet connection (Link) between the port
and another Ethernet device, and that there is communications activity.
On Solid = Indicates that there is a proper Ethernet connection (Link) between the port
and another Ethernet device, but no communications activity is detected.
Off = Indicates that there is not a proper Ethernet connection (Link) between the port and
another Ethernet device. Make sure the cable has been plugged securely into the ports at both ends.
100 LED
The port LEDs are multifunctional and indicate link confirmation, activity, and speed.
ON = A 100 Mbps (100BaseT) connection is detected.
OFF = A 10 Mbps (10BaseT) connection is detected.
OK LED
This LED is not used in the standard model and will always be off. On special order units with dual power inputs, the OK LED will be lit when both the P1 and P2 pins have power applied.
ET-8xS-MIL_manual r07.doc Page 5 of 9 Last Revised: 16-Jan-14
Section 3
Mechanical Dimensions and Installation
Overview
The IP67 Industrial Ethernet Switch can be mounted either on its edge or flat, as shown below. All LED’s are visible from either mounting position.
NOTE: Mounting holes will accept a #12 size screw or smaller.
9.98" [253.5mm]
10.48" [266.2mm]
0.35" [8.9mm]
0.75" [19.1mm]
1.50" [38.1mm]
2.24" [56.9mm]
2.45" [62.2mm]
2.91" [74.0mm]
1.30" [33.0mm]
2.68" [68.1mm]
9.98" [253.5mm]
3.98" [101.1mm]
9.48" [240.8mm]
2.98" [75.7mm]
with no cap or plug installed
with cap installed (tether not shown) (typical)
with plug installed (no backshell and wiring not shown) (typical)
Pressure
Vent Plug
Dia. 0.200" [5.1mm]
RS232/USB
Port
(managed only)
Power Input
ET-8xS-MIL
ET-8xS-MIL_manual r07.doc Page 6 of 9 Last Revised: 16-Jan-14
Section 4
Power and Communication Wiring
Overview
The IP67 Industrial Switches can be powered from the same DC source that is used to power your other devices. 10 to 30 VDC needs to be applied between Pin A and Pin B as shown below.
NOTE: Any of the available mounting holes may be used for grounding and electrical bonding of the switch.
No Connection
1
4
3
2
6
Ethernet Wiring
All Models
(ET-8xS-MIL)
No
Connection
RX-
RX+
TX-
TX+
1
2
3
4
6
5
4
3
2
1
GND
RS232-RD
RS232-TD
USB-DP
USB-CNX
(VBUS)
USB-DM
--
Power Input Wiring
All Models
(ET-8xS-MIL)
DC Supply
++
C
B
A
Console Port Wiring
Managed Models
(ET-8MS-MIL)
6
2
3
4
1
5
No
Connection
6
5
5
(input)
(output)
(TX-*)
(RX+*)
(RX-*)
(TX+*)
* also allowed due to the auto-mdi/mdix-crossover
RS232 and USB
Shell=A, Insert=98, Contacts=P, Keying=A Shell=A, Insert=35, Contacts=S, Keying=N Shell=A, Insert=35, Contacts=S, Keying=A
ET-8xS-MIL_manual r07.doc Page 7 of 9 Last Revised: 16-Jan-14
Section 5
Mating Connections Wiring
Overview
The IP67 Industrial Switches meet or exceed all MIL-STD-38999 Series III for severe environmental applications. All connectors and their mating couplings have EMI shielding and ESD, moisture and corrosion resistance. All mating connectors will self-lock with one 360 degree turn of the coupling nut.
Mating Connections
The following mating plugs are suggested to interface with the switch:
Ethernet Plug
D38999/26WA35PN
(w/ pin contacts and Normal keying)
Power Plug
D38999/26WA98SA
(w/ socket contacts and “A" keying)
USB/RS232 Plug
D38999/26WA35PA
(w/ pin contacts and “A” keying)
Note: The W in the above recommended plugs specifies cadmium plating. However, you may choose a different plating to meet your requirements. The MIL receptacles on the switch have black nickel plating which is RoHS compliant.
Cable Distance
The maximum cable length for 10/100BaseT is typically 100 meters (328 ft.).
Typical Plug
ET-8xS-MIL_manual r07.doc Page 8 of 9 Last Revised: 16-Jan-14
Section 6
Service Information
Service Information
We sincerely hope that you never experience a problem with any Red Lion product. If you do need service, call Red Lion at 1-877-432-9908 for Technical Support. A trained specialist will help you to quickly determine the source of the problem. Many problems are easily resolved with a single phone call. If it is necessary to return a unit to us, an RO (Repair Order) can be obtained on the Red Lion website.
Red Lion tracks the flow of returned material with our RO system to ensure speedy service. You must include this RO number on the outside of the box so that your return can be processed immediately.
Be sure to have your original purchase order number and date purchased available. We suggest that you give us a repair purchase order number in case the repair is not
covered under our warranty. You will not be billed if the repair is covered under warranty. Please supply us with as many details about the problem as you can. The information you
supply will be written on the RO form and supplied to the repair department before your unit arrives. This helps us to provide you with the best service, in the fastest manner. Repairs are completed as soon as possible. If you need a quicker turnaround, ship the unit to us by air freight. We give priority service to equipment that arrives by overnight delivery.
We apologize for any inconvenience that the need for repair may cause you. We hope that our rapid service meets your needs. If you have any suggestions to help us improve our service, please give us a call. We appreciate your ideas and will respond to them.
For Your Convenience: Please fill in the following and keep this manual with your Red Lion system for future reference:
Serial #:__________________ Date Purchased: ___________________ Purchased From:______________________________________________
ET-8xS-MIL_manual r07.doc Page 9 of 9 Last Revised: 16-Jan-14
Loading...