Red Lion ET-8EG-MIL-1, ET-8MG-MIL-1 Users Manual

8-Port
Gigabit
Industrial
Ethernet
Switch
Contents at a Glance:
Section 1
General Information
Page 3
Section 2
Mechanical and Installation
Page 6
Section 3
Power and Communication Wiring
Page 7
Section 4
LEDs
Page 12
Section 5
Pressure Vent
Page 13
Section 6
Service and Contact Information
Page 14
USER MANUAL
Installation and Wiring Manual
This manual applies to the following products:
ET-8EG-MIL-1 IP67 unmanaged Ethernet switch with 8 Gigabit ports ET-8MG-MIL-1 IP67 managed Ethernet switch with 8 Gigabit ports
ET-8xG-MIL_manual.r08 Page 1 of 14 Last Revised: 24-Apr-15
Red Lion Controls 20 Willow Springs Circle York, PA 17406 USA 1-717-767-6511 support@redlion.net
Red Lion Protected Technology Policy - Red Lion protects your investment in Red Lion systems with
Note: All information in this document is subject to change without notice.
long-term planned technology and our unique Protected Technology Policy. We will continue to support the specified capabilities of standard Red Lion products for at least five years (twenty years for Industrial Managed Switches). We plan each product improvement and new feature to be upward compatible with existing designs and installations. Our goals are to make each new software release bring new power to your Red Lion systems and have every existing feature, applications program and data file continue to work. We protect your investment even further with a liberal five-year trade-in policy. Exchange standard products for upgraded versions of the same product to take advantage of new features and improvements at any time for five years. A prorated trade-in allowance will be given for your existing unit. Red Lion protects your long-term productivity with state-of-the-art planned technology and continued support.
Red Lion Statement of Limited Warranty - Red Lion, manufacturer of Red Lion products, warrants to
Buyer that products, except software, manufactured by Red Lion will be free from defects in material and workmanship. Red Lion's obligation under this warranty will be limited to repairing or replacing, at Red Lion's option, the defective parts within five (5) years of the date of installation, or within 60 months of the date of shipment from the point of manufacture, whichever is sooner. Products may be returned by Buyer only after permission has been obtained from Red Lion. Buyer will prepay all freight charges to return any products to the repair facility designated by Red Lion. This limited warranty does not cover losses or damages which occur in shipment to or from Buyer or due to improper installation, maintenance, misuse, neglect or any cause other than ordinary commercial or industrial applications. In particular, Red Lion makes no warranties whatsoever with respect to implied warranties of merchantability or fitness for any particular purpose. All such warranties are hereby expressly disclaimed. No oral or written information or advice given by Red Lion or Red Lion’s representative shall create a warranty or in any way increase the scope of this warranty. This limited warranty is in lieu of all other warranties whether oral or written, expressed or implied. Red Lion's liability shall not exceed the price of the individual units, which are the basis of the claim. In no event shall Red Lion be liable for any loss of profits, loss of use of facilities or equipment, or other indirect, incidental or consequential damages.
INSTALLATION WARNINGS - These products should not be used to replace proper safety
interlocking. No software-based device (or any other solid-state device) should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety. In particular, Red Lion disclaims any responsibility for damages, either direct or consequential, that result from the use of this equipment in any application. All power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods and in accordance with the authority having jurisdiction. Refer to section 1 for other important installation warnings.
FCC Statement - This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; Consult the dealer or an experienced radio/TV technician for help.
Copyright & Trademarks - Copyright 2014 Sixnet, Inc. All Rights Reserved.
ET-8xG-MIL_manual.r08 Page 2 of 14 Last Revised: 24-Apr-15
Red Lion Controls 20 Willow Springs Circle York, PA 17406 USA 1-717-767-6511 support@redlion.net
Section 1
General Specifications
Overview
This manual will help you install and maintain the switch which is offered as unmanaged (model ET-8EG-MIL-1) or managed (model ET-8MG-MIL-1). The unmanaged model requires no configuration and is completely “plug and play”. The managed model allows you to configure the switch to optimize and increase network performance.
Note: This manual only covers the installation and wiring of these switches. For
the managed model, refer to the separate Software User Manual for details on
configuring and using any of the management functions such as SNMP, RSTP,
IGMP, port mirroring, etc.
Basic Operation
Unlike an Ethernet hub that broadcasts all messages out all ports, these industrial Ethernet switches will intelligently route Ethernet messages only out the appropriate port. The major benefits of this are increased bandwidth and speed, reduction or elimination of message collisions, and deterministic performance when tied with real-time systems.
The switch supports 10BaseT (10 Mbps), 100BaseT (100 Mbps) and 1000BaseT (1000 Mbps) on 8 ports. Each of these ports independently and automatically senses the speed and duplex for best performance. They also offer auto-crossover and auto-polarity to assure a proper link with either straight or crossed wired cables or even when the cable is incorrectly wired.
Performance Specs
The switch has the following performance specifications. Note: All specifications are subject to change. Consult factory for latest information.
ETHERNET PERFORMANCE
8 Gigabit Ethernet ports for 10/100/1000 Mbps links  Store & forward wire-speed non-blocking switching
Managed or unmanaged model available  All IEEE 802.3 Ethernet protocols supported  Auto-negotiation for Ethernet speed and duplex  Auto-crossover for Ethernet MDI/MDIX wiring Auto-polarity for Ethernet TD and RD polarity Full or half duplex operation (auto or configurable) 8192 MAC addresses supported 32 Gbps Memory bandwidth Ethernet isolation 1500 VRMS 1 minute Connector: MIL-STD-38999 series III receptacle with shell/insert style 9-9, 9 socket
contacts & N keying
ETHERNET COMPLIANCE
IEEE 802.3 (Original Ethernet 10Mbps)  IEEE 802.3u (Fast Ethernet 100Mbps)  IEEE 802.3z (Gigabit Ethernet 1000Mbps)  IEEE 802.3x (Full-Duplex with Flow Control)  And many more
ET-8xG-MIL_manual.r08 Page 3 of 14 Last Revised: 24-Apr-15
Red Lion Controls 20 Willow Springs Circle York, PA 17406 USA 1-717-767-6511 support@redlion.net
POWER INPUT
Connector: MIL-STD-38999 Series III receptacle with shell size A, style 98, 3 pin
contacts and A keying
Input voltage range: 18-30 VDC (continuous) Input power: 12 W (typical under full load) Reverse polarity protection Meets MIL-STD-1275 for power protection Surge protection: 100 volts for 1 second Transient protection: 15,000 watts peak  Spike protection: 5,000 watts (10x for 10 uS)
or 250 volts (50x for 100 uS)
ENVIRONMENTAL
Operating temperature: -40 to +75°C (cold startup at -40°C) Storage temperature: -40 to +85 °C Humidity (non-condensing) 5 to 95% RH Vibration, shock and freefall per MIL-STD-810F and IEC68-2-6, -27 and -32 Vent plug for high altitude operation
PHYSICAL
Dimensions (L x W x H) 11 x 6 x 2.85” (279 x 152 x 72 mm) Weight (including caps) 3.5 lbs (1.6 Kg)  IP67 dust, oil and water-tight package protection
STANDARDS COMPLIANCE
FCC part 15 / ICES-003; EN55022; IEC61326-1  Safety : UL508 (CSA C22.2 No. 142) and ISA12.12.01 (CSA C22.2 No. 213)  MIL-STD-461E for EMC performance  MIL-STD-810F for environmental performance  MIL-STD-1275B for power protection
MANAGED MODELS
USB / RS232 console port via MIL-STD-38999 series III connector w/ shell size A,
style 35, 6 contacts & A keying
Real-Time-Ring or Rapid Spanning Tree for fault-tolerant ring or mesh networks  Priority queuing for real-time performance  SNMP v1 and V2 for network management  SNMP v3 for authentication and encryption  SNMP notifications (traps) for report on event  IGMP v1 & v2 for IP multicast filtering  VLAN (port & tag based) for traffic segregation  Message filtering to stop broadcast/multicast storms  RMON and port mirroring for diagnostics  Configuration via secure (https) Web interface, Telnet / SSH (network), terminal
(RS232) or SNMP (v1, v2, v3)
And much more (Contact us for latest features list)
ET-8xG-MIL_manual.r08 Page 4 of 14 Last Revised: 24-Apr-15
Red Lion Controls 20 Willow Springs Circle York, PA 17406 USA 1-717-767-6511 support@redlion.net
Safety Warnings
Strictly abiding by these warnings will help ensure the safe installation, startup and operation of the switch.
INSTALL THE SWITCH IN ACCORDANCE WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES.
LIGHTNING DANGER: DO NOT WORK ON EQUIPMENT DURING PERIODS OF LIGHTNING ACTIVITY.
WARNING
(EXPLOSION
HAZARD)
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2 (ZONE 2).
WARNING
(EXPLOSION
HAZARD)
WHEN IN HAZARDOUS LOCATIONS, DISCONNECT POWER BEFORE REPLACING OR WIRING UNITS.
WARNING
(EXPLOSION
HAZARD)
DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.
Consignes de Sécurité
démarrage et le fonctionnement de l'interrupteur.
ET NATIONAUX.
RIODES D’ACTIVITÉS DE FOUDRE.
(RISQUE
D’EXPLOSION)
CLASSE I, DIVISION 2 (ZONE 2).
(RISQUE
D’EXPLOSION)
D’ALIMENTATION AVANT DE REMPLACER OU DE BRANCHER DES MODULES.
(RISQUE
D’EXPLOSION)
À MOINS QUE L’ENVIRONNEMENT SOIT CONNU POUR ÊTRE LIBRE DE
CONCENTRATIONS INFLAMMABLES.
ET-8xG-MIL_manual.r08 Page 5 of 14 Last Revised: 24-Apr-15
Red Lion Controls 20 Willow Springs Circle York, PA 17406 USA 1-717-767-6511 support@redlion.net
Loading...
+ 9 hidden pages