509FX-A Industrial Ethernet Switch
THE INDUSTRIAL NETWORK COMPANY
509FX-A
N-Tron Networking Series
Unmanaged Industrial Ethernet Switch
PRODUCT FEATURES
• Full IEEE 802.3 and 1613 Compliance
• NEMA TS1/TS2 Compliance
• American Bureau of Shipping (ABS) Type Approval
• Eight (8) 10/100 BaseTX RJ-45 Ports
• One (1) 100BaseFX Port, ST (shown) or SC
• -40ºC to 85ºC Operating Temperature
• Auto Sensing 10/100BaseTX, Duplex, and MDIX
• Store-and-Forward Technology
• Up to 1.8 Gb/s MaximumThroughput
• Rugged Industrial DIN-Rail Enclosure
• Redundant Power Inputs (10-30 VDC)
• Bi-Color LEDs For Link, Speed, Activity & Duplex Status
Advanced Management Functions (With -A option only):
• IGMP Snooping
• VLAN
• QoS
• Trunking and Mirroring
™
• N-View
(Remote Monitoring Using OPC Technology)
PRODUCT OVERVIEW
The N-TRON® 509FX Series Industrial Ethernet Switch offers outstanding
performance and ease of use. It is ideally suited for connecting Ethernet enabled
industrial and/or security equipment and can be optionally con gured with advanced
Ethernet communication management functions.
Industrial Packaging and Speci cations
The 509FX, designed to operate in industrial environments, is housed in a rugged
DIN-rail-mounted steel enclosure. Optional panel and rack mount kits are also
available. The switch comes standard with extended temperature rating, extended
shock and vibration specs, redundant power inputs, and a high MTBF (greater
than 2M hours).
Ease of Use
The 509FX requires no setup unless the advanced port functions are utilized. The
eight 10/100BaseTX ports are auto sensing and auto con guring. Each copper port
automatically negotiates for maximum speed and performance by default. The ber
optic port supports full 200Mb/s communications via 100BaseFX. Bi-color LEDs
are provided to display the link status, link speed and activity of each port as well
as power on/off status.
Performance
The 509FX supports up to 4,000 MAC addresses and uses advanced IEEE 802.3
Fast Ethernet 10/100BaseTX switching technology to eliminate network collisions
and increase network determinism. A high-speed processor and backplane allow
full-wire speed capability on all ports simultaneously.
ADVANCED MANAGEMENT FEATURES
The 509FX-A offers several management functions that can be easily con gured
using the COM Port (DB 9 connector located on the right side of the switch).
IGMP Snooping: Internet Group Management Protocol allows the N-Tron switch
to intelligently forward and lter multicast traf c.
VLAN: Virtual Local Area Network allows switch segmentation in order to create
two or more separate local area network domains.
QoS: Quality of Service streamlines network operation by managing packet
priority. The primary goal of QoS is to improve the latency of prioritized Ethernet
packets required for ring management, real-time and other interactive applications.
Trunking: Trunking (aggregation) enables multiple physical ports to be linked
together and function as one uplink to another identically con gured trunking-
capable switch. This feature increases the bandwidth between switches and
creates redundancy for applications requiring high levels of fault tolerant operation.
Port Mirroring: Port mirroring allows traf c on one port to be duplicated and
sent to a designated mirror port. This function can be used to monitor Ethernet
traf c on the designated source port using the assigned mirror port.
N-View OPC Switch Monitoring: (With -A or -N Option Only) N-View OPC
server software can be used with popular HMI software packages to transmit
operational information from N-View-capable switches. This technology enables
network traf c monitoring, as well as alarm and trending details. In all, the N-View
OPC Server collects 41 different traf c variables per port and ve system level
variables per switch, providing a complete overview of network load, service
quality, and packet traf c. Empowered with N-View OPC Server data, users can
resolve network problems faster and make more informed decisions about overall
system performance.
509FX-A Specifications
Regulatory Approvals
FCC/CE (CFR 47, Part 15, Subpart B, Class A); ICES-003
EMC Dir 89/336/EEC, EN 50204, EN 55011
EN61000-4-2, 3, 4, 5, 6, 8,11, EN61000-6-2, 4
ANSI C63.4
UL /cUL: Class I, Div 2, Groups A, B, C, D and T4
UL 508 and UL 1604
CAN/CSA-C22.2 No.213, ATEX II 3 G Ex nA
IEEE 1613 for Electric Utility Substations
ABS Type Approval for Shipboard Applications
GOST-R Certi ed, RoHS Compliant
Fiber Transceiver Characteristics
Fiber Length 2km* 15km** 40km** 80km**
TX Power Min -19dBm -15dBm -5dBm -5dBm
RX Sensitivity Max -31dBm -31dBm -34dBm -34dBm
Wavelength 1310nm 1310nm 1310nm 1550nm
* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable
509FX-A
Speci cations
Switch Properties
Number of MAC Addresses: 4,000
Aging Time: 300s, Programmable (-A option)
Latency Typical: 2.1 μs
Switching Method: Store & Forward
Case Dimensions
Height: 2.3" (5.8 cm)
Width: 5.5" (13.9 cm)
Depth: 3.5" (8.9 cm)
Weight: 1.6 lbs (0.8 kg)
Din-Rail: 35 mm
Electrical
Redundant Input Voltage: 10-30 VDC
Input Current: 260 mA @ 24 VDC
BTU/hr: 21.3 @ 24 VDC
Inrush: 8.5 amp/0.7ms @24 VDC
Environmental
Operating Temperature: -40oC to 85oC
Storage Temperature: -40
o
C to 85oC
Operating Humidity: 10% to 95% (Non Condensing)
Operating Altitude: 0 to 10,000 ft.
Regulatory Approvals
FCC/CE (CFR 47, Part 15, Subpart B, Class A); ICES-003
EMC Dir 89/336/EEC, EN 50204, EN 55011
EN61000-4-2, 3, 4, 5, 6, 8,11, EN61000-6-2, 4
ANSI C63.4
UL /cUL: Class I, Div 2, Groups A, B, C, D and T4
UL 508 and UL 1604
CAN/CSA-C22.2 No.213, ATEX II 3 G Ex nA
IEEE 1613 for Electric Utility Substations
ABS Type Approval for Shipboard Applications
GOST-R Certi ed, RoHS Compliant
Designed to comply with:
NEMA TS1/TS2 for Traf c Control
Fiber Transceiver Characteristics
Fiber Length 2km* 15km** 40km** 80km**
TX Power Min -19dBm -15dBm -5dBm -5dBm
RX Sensitivity Max -31dBm -31dBm -34dBm -34dBm
Wavelength 1310nm 1310nm 1310nm 1550nm
* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable
Fiber Transceiver Characteristics
Fiber Length 2km* 15km** 40km** 80km**
TX Power Min -19dBm -15dBm -5dBm -5dBm
RX Sensitivity Max -31dBm -31dBm -34dBm -34dBm
Wavelength 1310nm 1310nm 1310nm 1550nm
* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable
Speci cations
Switch Properties
Number of MAC Addresses: 4,000
Aging Time: 300s, Programmable (-A option)
Latency Typical: 2.1 μs
Switching Method: Store & Forward
Case Dimensions
Height: 2.3" (5.8 cm)
Width: 5.5" (13.9 cm)
Depth: 3.5" (8.9 cm)
Weight: 1.6 lbs (0.8 kg)
Din-Rail: 35 mm
Electrical
Redundant Input Voltage: 10-30 VDC
Input Current: 260 mA @ 24 VDC
BTU/hr: 21.3 @ 24 VDC
Inrush: 8.5 amp/0.7ms @24 VDC
Environmental
Operating Temperature: -40oC to 85oC
Storage Temperature: -40
Operating Humidity: 10% to 95% (Non Condensing)
Operating Altitude: 0 to 10,000 ft.
Fiber Transceiver Characteristics
Fiber Length 2km* 15km** 40km** 80km**
TX Power Min -19dBm -15dBm -5dBm -5dBm
RX Sensitivity Max -31dBm -31dBm -34dBm -34dBm
Wavelength 1310nm 1310nm 1310nm 1550nm
o
C to 85oC
* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable
Shock and Vibration (bulkhead mounted)
Shock: 200 g @ 10ms
Vibration/Seismic: 50 g, 5-200 Hz, Triaxial
Reliability
MTBF: >2 Million Hours
Serial Con guration Port
Com Parameters: 9600,n,8,1
Network Media
10BaseT: ≥Cat3 Cable
100BaseTX: ≥Cat5 Cable
100BaseFX:
Multimode:
Singlemode:
50-62.5/125μm
7-10/125μm
Connectors
10/100BaseTX: Eight (8) RJ-45 Copper Ports
100BaseFX: One (1) SC or ST Duplex Port
Recommended Wiring Clearance
Front: 4" (10.2 cm)
Side: 1" (2.6 cm)
Regulatory Approvals
FCC/CE (CFR 47, Part 15, Subpart B, Class A); ICES-003
EMC Dir 89/336/EEC, EN 50204, EN 55011
EN61000-4-2, 3, 4, 5, 6, 8,11, EN61000-6-2, 4
ANSI C63.4
UL /cUL: Class I, Div 2, Groups A, B, C, D and T4
UL 508 and UL 1604
CAN/CSA-C22.2 No.213, ATEX II 3 G Ex nA
IEEE 1613 for Electric Utility Substations
ABS Type Approval for Shipboard Applications
GOST-R Certi ed, RoHS Compliant
Designed to comply with:
NEMA TS1/TS2 for Traf c Control