CAUTION – RISK OF SHOCK – Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.
1) Attach mounting strap[1] to outlet box[2]. Mounting strap can
be adjusted to suit position of xture.
2) Grounding instructions: (See Illus. A or B)
A) On xtures where mounting strap is provided with a hole
and two raise dimples. Wrap ground wire from outlet box around green ground screw, and thread into hole.
B) On xtures where a cupped washer is provided. Put
ground wire from outlet box under cupped washer and green ground screw and thread screw into hole in mount-
ing strap.
If xture is provided with ground wire. Connect xture ground
wire to outlet box ground wire with wire connector, after follow­ing the above steps. Never connect ground wire to black or white power supply wires.
4
6
5
A
OUTLET BOX
GROUND
GREEN GROUND
SCREW
WIRE CONNECTOR
FIXTURE GROUND
DIMPLES
OUTLET BOX
GROUND
GREEN GROUND
SCREW
B
FIXTURE GROUND
CUPPED WASHER
3) Make wire connections. Reference chart below for correct con-
nections and wire accordingly.
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Insulated wire (other than green)
with copper conductor
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.)
Neutral Wire
2
3
1
9
7
11
10
8
4) Push xture to wall carefully passing mounting screws[3] with holes in canopy[4]. Make sure all wires are inside canopy and do not get pinched between wall and canopy of xture.
5) Thread lockup knobs[5] onto mounting screws and tighten to secure xture to wall.
6) Insert recommended bulb(s) (Not supplied).
7 Raise the glass[7] up to the xure. Carefully pass over the
socket[8], and align the holes on the bracket[9] with the holes in the xture roof[10].
8) Thread a screw[11] into each hole from the bottom side of the xture roof. Tighten screws to secure the glass into place.
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/ OR IN WET LOCATIONS.
9) Mounting surface should be clean, dry, at and 1/4” larger that the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as
required.
10) With silicone caulking compound, caulk completely around where back of canopy meets the wall surface to prevent water
from seeping into outlet box.
Page 2
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
INSTRUCTIONS
ATTENTION – RISQUE DE DÉCHARGES ÉLECTRIQUES ­Couper le courant au niveau du panneau du disjoncteur du circuit principal ou de la boîte à fusibles principale avant de
procéder à l’installation.
1) Visser la barrette de montage[1] à la boite de jonction[2]. La barrette de montage peut etre ajustée pour convenir à la posi-
tion de l’applique.
Connecter le fil noir ou
rouge de la boite
Connecter le fil blanc de la boîte
A Noir A Blanc
*Au cordon parallèle (rond et lisse)
Au bransparent, doré, marron, ou
noir sans fil distinctif
Fil isolé (sauf fil vert) avec
conducteur en cuivre
*Au cordon parallele (à angles droits el strié)
Au transparent, doré, marron, ou
noir avec un til distinctif
Fil isolé (sauf fil vert) avec
conducteur en argent
*Remarque: Avec emploi d’un fil paralléle (SPT I et SPT II). Le fil neutre est á angles droits ou strié et l’autre fil doit étre rond ou lisse (Voir le schéma).
Fil Neutre
4
6
2
3
1
5
10
8
11
2) Connecter les ls (connecteurs non fournis). Se reporter au tableau ci-dessous pour faire les connexions.
3) Visser les boules letées sur les vis de montage[3][4]. Serrer les boules letées pour xer le luminaire au mur.
4) Visser les boules de blocage[5] sur les vis de xation[6]. Serrer es boules de blocage pour xer le luminaire au mur.
5) Installer la ou les ampoules recommandées (non fournies).
6) Soulever le verre [7] jusqu’à la xation. Passez soigneusement la douille [8] et alignez les trous sur le support [9] avec les trous dans le toit de l’appareil [10].
7) Enler une vis [11] dans chaque trou de la partie inférieure du toit de l’appareil. Serrez les vis pour xer le verre en place.
INSTRUCTIONS DE MONTAGE DE LUMINAIRE À L’EXTÉRIEUR ET/OU DANS DES LIEUX HUMIDES.
8) La surface de montage doit être propre, sèche, plate et de 0,6 cm plus épaisse que le cache sur tous les côtés. Tout écart entre la surface de montage et le cache dépassant de 0,5 cm doit être rectié selon les besoins.
9) À l’aide de matériaux d’étanchéité à la silicone, calfeutrer bien autour où l’arrière du cache entre en contact avec le mur pour empêcher l’eau de passer dans la boîte de raccordement.