HUIZHOU RELAX LOUNGE CO., LIMITED
FLOOR 1,2, TAIHU BUILDING, BAISHI VILLAGE, QIUCHANG TOWN, HUIYANG DISTRICT, HUIZHOU CITY
Sample Description :
Style No. :
Item No. :
P.O. / Ref. No. :
Country of Origin :
Country of Destination :
As above test item and its relevant information regarding to the submission are provided and confirmed by the
applicant. SGS is not liable to either the test item or its relevant information, in terms of the accuracy, suitability,
reliability or/and integrity accordingly.
SGS Ref No. :
Test Report
No.SDHL2103004484FT Date: Apr 01, 2021 Page 1 of 3
-173.
************
Sample Receiving Date :
Test Performing Date :
Test Performed :
No. Test(s) Requested Result(s) Comments
1 California Technical Bulletin 117-2013 R2019 Section 1 PASS /
For further details, please refer to the following page(s)
Signed for and on behalf of
SGS-CSTC Standards Technical Services Co., Ltd. Shunde Branch
Bill Wang
Authorized Signatory
to Apr 01, 2021
test(s) as requested by applicant
Test Result Summary

Test Conducted:
TB117 Requirements, Test Procedure and Apparatus for Testing the Smolder Resistance of Materials Used in
Upholstered Furniture-2013 R2019 Section 1- Cover Fabric Test
I. Sample Details
II. Test Condition
III. Acceptance Criteria:
1. A single mock-up test specimen fails to meet the requirements of this test procedure if any of the following
criteria occurs:
Test Report
Material: Fabric Density of sample: 359 g/m2
--- Temperature Relative humidity Duration
Conditioning of test
samples and cigarettes
No.SDHL2103004484FT Date: Apr 01, 2021 Page 2 of 3
(21±3)°C
RH < 55 %
24h
a) The mock-up test specimen continues to smolder after the 45 minutes test duration;
b) A vertical char length of more than 1.8 inches develops on the cover fabric;
c) The mock-up test specimen transitions to open flaming.
2. The cover fabric passes the test if three initial mock-up specimens pass the test, i.e., the cigarettes burn their
full length and the mock-ups are no longer smoldering.
3. If more than one initial specimen fails, the cover fabric fails the test.
4. If any one of the three initial specimens fails, repeat the test on additional three specimens.
5. If all three additional specimens pass the test, the cover fabric passes the test. If any one of the additional three
specimens fails, the cover fabric fails the test.
IV. Test Result
Specimen #
1 30min53s NO 0.7 PASS
2 29min44s NO 0.6 PASS
3 30min21s NO 0.7 PASS
Conclusion: PASS
Duration of smouldering
( min : sec.)
Open flaming
(YES/NO)
Vertical Char Length
(inches)
Rating

Photo Appendix:
Test Report
No.SDHL2103004484FT Date: Apr 01, 2021 Page 3 of 3
***End of Report***