Redback A 2082 Operating Instructions Manual

Doc. PS801
A 2082 Amplifier Monitor Panel
®
www.altronics.com.au
Proudly Assembled in Australia
TING INSTRUCTIONS
Distributed by Altronic Distributors Pty. Ltd. Perth. Western Australia.
This easy to install unit has the ability to monitor 12 different 100V line signals.The unit has indiviual in/out screw terminal on the rear panel for simple installation.
Each zone can be monitored via the VU meter on the front of the unit or by listening via the in-built speaker. The volume of the speaker may be controlled via the volume control on the front panel.
The 12 position switch is used to select the amplifier you wish to monitor.
F
EATURES
• 19” 2U Rack mount or desk mount
• Volume control
• No power required
• Minimal circuitry with no signal loss
• Monitors up to twelve 100V line amplifiers
• VU output level display
• In-built monitor speaker
• 2 Year warranty
• Made in Australia
INSTALLATION INSTRUCTIONS
To install the unit you will need to connect up the output of the 100V line amplifiers you wish to monitor.
Ensure the screw connections are secure on both the speaker out terminals and the amplifier out terminals.
Connect the output of the amplifier to the “From amplifier” terminals and connect the speaker to the “To speaker load” terminals.
OPERATING INSTRUCTIONS
To operate the unit select the amplifier you wish to monitor via amplifier selection switch. Any signal From the amplifier can be observed on the VU meter. Turn up the volume for the speaker using the Monitor volume control. The signal you have put into the amplifier should be able to be heard on the in-built speaker.
You may switch between amplifiers at any time without affecting normal operation.
REDBACK A 2082 Amplifier Monitor Panel
Page 2
OUTPUT CONNECTORS:
............................................Screw Terminals
INPUT CONNECTORS:
............................................Screw Terminals
INDICATORS: .................................VU Meter
DIMENSIONS: ............482W x 152D x 88H
WEIGHT:.............................................. 2.6 kg
COLOUR: ..................................................Black
* Specifications subject to change without notice.
SPECIFICATIONS
NO DISPLAY ON VU METER
• Check connections to monitor panel
• Check that the amplifier selection switch is in the correct position
• Ensure the amplifier has a signal going to it
NOSOUND TO IN-BUILT SPEAKER
• Check connections to monitor panel
• Ensure that the volume control is turned to an audible level
• Check the signal source
T
ROUBLESHOOTING
Not field serviceable: For repair contact
Altronics for your nearest Service Centre :
Altronic Distributors Pty. Ltd. Perth W.A. 6000