Doc. PS801
A 2082 Amplifier
Monitor Panel
www.altronics.com.au
Proudly Assembled in Australia
OPERA
TING INSTRUCTIONS
Distributed by Altronic Distributors Pty. Ltd. Perth. Western Australia.
This easy to install unit has the ability to monitor 12
different 100V line signals.The unit has indiviual in/out
screw terminal on the rear panel for simple installation.
Each zone can be monitored via the VU meter on the
front of the unit or by listening via the in-built speaker.
The volume of the speaker may be controlled via the
volume control on the front panel.
The 12 position switch is used to select the amplifier you
wish to monitor.
F
EATURES
• 19” 2U Rack mount or desk mount
• Volume control
• No power required
• Minimal circuitry with no signal loss
• Monitors up to twelve 100V line amplifiers
• VU output level display
• In-built monitor speaker
• 2 Year warranty
• Made in Australia
INSTALLATION INSTRUCTIONS
To install the unit you will need to connect up the output
of the 100V line amplifiers you wish to monitor.
Ensure the screw connections are secure on both the
speaker out terminals and the amplifier out terminals.
Connect the output of the amplifier to the “From
amplifier” terminals and connect the speaker to the “To
speaker load” terminals.
OPERATING INSTRUCTIONS
To operate the unit select the amplifier you wish to
monitor via amplifier selection switch. Any signal From
the amplifier can be observed on the VU meter. Turn up
the volume for the speaker using the Monitor volume
control. The signal you have put into the amplifier
should be able to be heard on the in-built speaker.
You may switch between amplifiers at any time without
affecting normal operation.

REDBACK A 2082 Amplifier Monitor Panel
Page 2
OUTPUT CONNECTORS:
............................................Screw Terminals
INPUT CONNECTORS:
............................................Screw Terminals
INDICATORS: .................................VU Meter
DIMENSIONS: ............≈ 482W x 152D x 88H
WEIGHT:.............................................. ≈ 2.6 kg
COLOUR: ..................................................Black
* Specifications subject to change without notice.
SPECIFICATIONS
NO DISPLAY ON VU METER
• Check connections to monitor panel
• Check that the amplifier selection switch is in the correct
position
• Ensure the amplifier has a signal going to it
NOSOUND TO IN-BUILT SPEAKER
• Check connections to monitor panel
• Ensure that the volume control is turned to an audible
level
• Check the signal source
T
ROUBLESHOOTING
Not field serviceable: For repair contact
Altronics for your nearest Service Centre :
Altronic Distributors Pty. Ltd. Perth W.A. 6000
Phone: (08) 9428 2199 Fax: (08) 9428 2198