Redback A 1708 Operating Manual

User manual revision number: 1.0 13/05/2015
Operating Manual
A 1708 50 Event 4 Output 24 Hour 7 day Timer
Redback® Proudly Made In Australia
IMPORTANT NOTE:
Please read these instructions carefully from front to back prior to installation.
They include important setup instructions.
Redback® Proudly Made In Australia
2
1.0 OVERVIEW
The A 1708 is a versatile timer which has four switched 24V DC outputs and four closing contacts which activate simultaneously. It permits a total of 50 station (event) switching times. Each can be set to turn on any single day of the week or on multiple days, from 1 sec up to 24 hours. Switching events programmed for multiple days count as only a single station (event) and each of the 50 event times may be set to any (but not multiple) output.
Manual override is provided so that any of the four outputs can be set “ON” or “OFF” manually which overrides any of the event times programmed for that output.
The unit has security lock out of Time Edit, Station Edit and Clear Memory Functions via DIP switch selections on the rear of the unit.
2.0 OPERATION
On the front of the timer there are 3 groups of LED’s which provide a visual indicator of the status of each of the four output zones. The red LED’s indicate a zone is in “Auto” mode and therefore the output of that zone will be controlled by whatever event times have been programmed into the timer. The green LED’s indicate that a zone is in “Manual” mode and therefore has been manually set to be either “ON” or “OFF” by the user. Once a zone is in “Manual” mode it will stay in this mode until the user sets it back to “Auto” mode. The amber LED’s indicate the output status of the zone. On the rear of the unit are the 24V DC switched outputs and four sets of closing contacts. If a zone is set to “ON” the corresponding switched output will become active and 24V DC will be present at the terminals. At the same time the closing contact for that zone will short, and stay that way until the zone is again set “OFF”. (NOTE: the 24V DC outputs switch the voltage supplied to the unit via the 24V DC input connector. Therefore the output voltage is determined by the voltage supplied to power the unit).
In order to setup the unit to run automatically, the station (or event) times will need to be programmed. There are ve buttons on the front of the timer which are used to program the unit and navigate the various menus.
3.0 NAVIGATING THE MENUS
When the unit is rst powered up, the model number and Chipset will be displayed briey before the current time is shown.
The main screen (Current Time Screen) shown in Fig 3.2 displays the current time. When this screen is displayed the unit is running in “AUTO MODE” and therefore all outputs will work as programmed. However if the unit is in any of the sub menu’s (Menu Mode) the unit will no longer respond to any event that has been programmed to occur, while the unit remains in menu mode. On exiting the menu, the timer will check all programmed events and update the status of the output zones.
Fig 3.1
Monday 07:00:00
Fig 3.2
SPECIAL NOTE ABOUT “AUTO MODE” OPERATION
If the timer is not displaying the main clock screen, where the time is changing, the unit is
not running in “Auto Mode”. This means it will not be checking any of the programmed
events and hence will not activate any outputs automatically.
Essentially this means that as soon as the Menu button is pressed the unit is no longer in
“Auto Mode”.
Make sure to return to the main screen by exiting all menu’s when not making changes.
Altronics A 1708 DS3231 Chipset 1
Redback® Proudly Made In Australia
3
1) Manual select of output zones
2) Add or edit a Station time
3) Edit time on clock
4) Clear memory of ON/OFF times.
5) Exit Main Menu
Monday 07:00:00
Menu
Main Screen
Press the UP and DOWN buttons to scroll up and down.
Enter
Press the ENTER button to make your selection
Menu
Press the MENU button to exit at any time.
Press the “Menu” button on the front of the timer. The unit is now in “Menu Mode” and the screen should display the Manual Select of Output Zones Screen. This is the rst of 5 sub menu screens which are navigated by pressing the up and down buttons as shown in Fig 3.3. Pressing the Menu button again will return the user to the Main Screen. Select the desired sub menu by pressing the “Enter” button.
Fig 3.3
3.1 SUB MENU’S
There are 4 options to choose from.
1) Manual Selection Of Output Zones
2) Add or Edit A Station Time
3) Edit Time on Clock
4) Clear Memory of ON/OFF Times
3.1.1 Manual Selection OF Output Zones
After selecting this option the screen should appear as shown in Fig 3.4. The square brackets indicate the cursor position on the screen.
OUTPUT 1
[AUTO] ON OFF
Fig 3.4
Redback® Proudly Made In Australia
4
Enter
Manual Selection Screen
OUTPUT 1
[AUTO] ON OFF
OUTPUT 1
AUTO [ON] OFF
OUTPUT 1
AUTO ON [OFF]
1) Manual select of output zones
OUTPUT 2
[AUTO] ON OFF
OUTPUT 2
AUTO [ON] OFF
OUTPUT 2
AUTO ON [OFF]
OUTPUT 3
[AUTO] ON OFF
OUTPUT 3
AUTO [ON] OFF
OUTPUT 3
AUTO ON [OFF]
OUTPUT 4
[AUTO] ON OFF
OUTPUT 4
AUTO [ON] OFF
OUTPUT 4
AUTO ON [OFF]
Exit Manual
Zone Selection
Press the UP and DOWN buttons to scroll up and down.
Enter
Press the ENTER button to make your selection
Menu
Press the MENU button to exit at any time.
Fig 3.5
SPECIAL NOTE FOR FIRST TIME USE:
When powering up the unit for the rst time it will be necessary to
clear the memory before entering any Station (Event) times. If this is not
done the unit will not operate correctly. To do this use option 4 in the
menu. Refer to the section on “Clearing the Memory”.
Navigate to the “Add or Edit a Station Time” Sub Menu as shown in Fig 3.3. If this is the rst time entering this menu the screen should appear as shown in Fig 3.6. The number “1)” shown is the Station (or Event) number which is highlighted by a ashing cursor.
3.1.2 Add or Edit A Station Time
This option allows the user to enter the Station (Event ) information which includes the event “Turn on time”, “Duration” and “Output Zone”.
If this is the rst time an Event has been entered the memory will need to be “Cleared” rst. To do this follow the directions in the section “Clearing the Memory”.
1) - DAY
Start @ 00:00:00
Fig 3.6
To set a Zone manually, scroll to the desired zone using the up and down buttons as shown in Fig 3.5 and then press “Enter” when you reach your selection. When nished scroll to the “Exit Manual Zone Selection” screen and press “Enter” or press the “Menu” button to exit at any time. (NOTE: For the unit to continue in “AUTO MODE” you must exit back to the Main Screen.)
SPECIAL NOTE:
If power is removed, all outputs will switch off and all zones will
return to Auto mode once power is restored.
Redback® Proudly Made In Australia
5
From this point the user can scroll through all 50 stations using the up and down buttons as shown in g 3.7. This makes it very easy to view all Station time settings at a glance. Once the station number desired is shown on the LCD press the “Enter” button to conrm and move to the next step which is to make changes to the station “day”.
Fig 3.7
Enter
Press the UP and DOWN buttons to scroll up and down.
Enter
Press the ENTER button to make your selection
Menu
Press the MENU button to exit at any time.
2) Add or edit a Station time
50) - DAY Start @ 00:00:00
1) - DAY Start @ 00:00:00
2) - DAY Start @ 00:00:00
3) - DAY Start @ 00:00:00
49) - DAY Start @ 00:00:00
Station (or Event) number
Press the +10 button to scroll up 10 stations
+10
The DAY represents the day of the week that the Event will take place and can be any day from Monday to Sunday or one of many multiple day options which are listed below. Pressing the up and down buttons will scroll through the days monday to friday and then through the multiple days.
Mon-Fri Sat-Sun Mon/Wed/Fri Tue/Thu/Sat Mon-Thur Mon-Sun Tue-Fri Mon/Fri Tue/Wed/Thu Mon/Wed Mon/Thur Mon/Tue/Thu Tue/Thur Tue/Wed/Fri Tue/Thu/Fri Wed/Fri Mon/Tue/Wed
Press the UP and DOWN buttons to scroll up and down.
Enter
Press the ENTER button to make your selection
Menu
Press the MENU button to exit at any time.
1) Mon/Tue/Wed Start @ 00:00:00
1) Monday Start @ 00:00:00
1) Tuesday Start @ 00:00:00
1) Wednesday Start @ 00:00:00
1) - Wed/Fri Start @ 00:00:00
Day of the week
1) DAY Start @ 00:00:00
Fig 3.8
Once the day or multiple days desired is shown on the LCD, press the “Enter” button to conrm. The cursor will now move to the start time. This is the time the “Event” is to take place and is in 24 hour format.
Redback® Proudly Made In Australia
6
The cursor is now positioned over the hour section of the start time as shown in Fig 3.9.
Press the UP and DOWN buttons to change the hour/min/secs.
Enter
Press the ENTER button to make your selection
Menu
Press the MENU button to exit at any time.
1) Monday Start @ 23:00:00
1) Monday Start @ 00:00:00
1) Monday Start @ 01:00:00
1) Monday Start @ 02:00:00
1) Monday Start @ 22:00:00
Start time
1) Monday Start @ 00:00:00
Press the +10 button to scroll up 10 hours/min/secs
+10
Fig 3.9
Change the hour by pressing the +10, up and down buttons and press “Enter” when nished. The cursor will now move to the minute section of the start time. Repeat the above procedure to change the minutes and press “Enter” when nished. The cursor will now move to the seconds section of the start time. Repeat the above procedure again to change the seconds and press “Enter” when nished. The start time is now set for this Station (or Event). After completing the start time, the screen will change to the Zone and Duration options screen as shown in Fig 3.10.
Fig 3.10
1) ZONE DURATION
OFF 00:00:00
From this point the user can scroll through all 50 stations using the up and down buttons as shown in g 3.11. This makes it very easy to view all Output Zone settings at a glance. Once the station number desired is shown on the LCD press the “Enter” button to conrm and move to the next step which is to make changes to the zone output.
Fig 3.11
Enter
Press the UP and DOWN buttons to scroll up and down.
Enter
Press the ENTER button to make your selection
Menu
Press the MENU button to exit at any time.
Station (or Event) number
Press the +10 button to scroll up 10 stations
+10
1) ZONE DURATION OFF 00:00:00
1) ZONE DURATION OFF 00:00:00
2) ZONE DURATION OFF 00:00:00
3) ZONE DURATION OFF 00:00:00
49) ZONE DURATION OFF 00:00:00
50) ZONE DURATION OFF 00:00:00
Redback® Proudly Made In Australia
7
Press the UP and DOWN buttons to change the zone output.
Enter
Press the ENTER button to make your selection
Menu
Press the MENU button to exit at any time.
Zone Output
1) ZONE DURATION 1 00:00:00
1) ZONE DURATION 2 00:00:00
1) ZONE DURATION 3 00:00:00
1) ZONE DURATION OFF 00:00:00
1) ZONE DURATION 4 00:00:00
Fig 3.12 illustrates the Zone Output setup procedure. There are 4 output zones to choose from. Use the up and down buttons to change the zone output and press “Enter” when nished. The zone can also be set to “OFF” which will turn this output off, but not affect the time settings so that it can easily be re-initiated by setting the zone output later.
Fig 3.12
The cursor is now positioned over the hour section of the Zone Duration as shown in Fig 3.13. The duration is the amount of time the event will occur for, after the start time.
Fig 3.13
Change the hour by pressing the +10, up and down buttons and press “Enter” when nished. The cursor will now move to the minute section of the duration. Repeat the above procedure to change the minutes and press “Enter” when nished. The cursor will now move to the seconds section of the duration. Repeat the above procedure again to change the seconds and press “Enter” when nished. The menu button can be pressed at any time to exit the setup. The duration is now set for this Station (or Event). After completing the duration, the screen will change to the next station ready to enter the next events details.
NOTE: IF the duration is set to 00:00:00 the zone output will be set back to “OFF” on exiting the “Set Duration” screen.
Press the UP and DOWN buttons to change the hour/min/secs.
Enter
Press the ENTER button to make your selection
Menu
Press the MENU button to exit at any time.
Zone Duration
Press the +10 button to scroll up 10 hours/min/secs
+10
1) ZONE DURATION 1 00:00:00
1) ZONE DURATION 1 00:00:00
1) ZONE DURATION 1 01:00:00
1) ZONE DURATION 1 02:00:00
1) ZONE DURATION 1 22:00:00
1) ZONE DURATION 1 23:00:00
Redback® Proudly Made In Australia
8
3.1.3 Edit the Clock Time
This option sets the current time.
After selecting the “Edit Time on Clock” option from the menu shown in Fig 3.3 the LCD will display the screen shown in Fig 3.13 where the cursor ashes on the current day.
Pressing the up and down buttons will scroll through the days Monday to Sunday. Pressing “Enter” will conrm the day and then move the cursor to the hour option as shown in Fig 3.14.
Press the UP and DOWN buttons to change the hour/min/secs.
Enter
Press the ENTER button to make your selection
Menu
Press the MENU button to exit at any time.
Clock Time
Monday 00:00:00 Edit
Monday 01:00:00 Edit
Monday 02:00:00 Edit
Monday 22:00:00 Edit
Monday 23:00:00 Edit
Press the +10 button to change the hour/min/secs.
+10
Press the UP and DOWN buttons to change the day.
Enter
Press the ENTER button to make your selection
Menu
Press the MENU button to exit at any time.
Clock Day
Monday 00:00:00 Edit
Tuesday 00:00:00 Edit
Wednesday 00:00:00 Edit
Saturday 00:00:00 Edit
Sunday 00:00:00 Edit
Enter
3) Edit time on clock
Fig 3.13
Fig 3.14
Change the hour by pressing the +10, up and down buttons and press “Enter” when nished. The cursor will now move to the minute section of the clock time. Repeat the above procedure to change the minutes and press “Enter” when nished. The cursor will now move to the seconds section of the clock time. Repeat the above procedure again to change the seconds and press “Enter” when nished. The menu button can be pressed at any time to exit the setup. The clock time is now set. After completing the clock time, the screen will change to the current time.
Redback® Proudly Made In Australia
9
3.1.4 Clearing the Memory
This function will clear the internal memory, erasing any information entered.
Not Available
Check Settings
Fig 3.15
This is one of the security options to protect the information stored in memory. See the DIP Switch settings for more information. Set the DIP switch 4 to “OFF” and then press “Enter” again. This time you should enter the Clearing the Memory Sub Menu. The following two screens should be briey displayed.
This will clear
all ON/OFF times
Are you sure?
Then you will be asked to press “Enter” to conrm you want to clear the memory or press “Menu” to exit.
Hold ENTER for Y
or MENU for No
If you press Menu you will return to the Clear Memory Sub Menu. If you press Enter, the unit will cycle through the memory locations clearing any data stored. This will take a few minutes. Once nished you will return back to the Clear Memory Sub Menu.
NOTE: It is advisable to now set DIP switch 4 to “ON” to prevent accidental clearing of the memory.-
IMPORTANT NOTE:
Ensure power is switched off when adjusting DIP switches.
New settings will be effective when power is switched back on.
4.0 DIP SWITCH SETTINGS
There are four DIP switches accessible on the rear of the A 1708 which are for selecting the backup battery and various security lockout features (See Fig 4.1).
DIP Switch Settings
SW ON
1 2
Station Edit Lockout Enabled
3
Edit Time Lockout Enabled
4
Clear Memory Lockout Enabled
Battery Backup On
Fig 4.1
IMPORTANT NOTE:
The memory must be cleared before using the unit for the rst time.
Navigate to the “Clear Memory of ON/OFF times” Sub Menu as shown in Fig 3.3. Press “Enter” to activate this option. If DIP switch 4 is set to “ON” the screen will display the message shown in Fig 3.15.
Switch 1 - Battery Backup
When switch 1 is set to the “ON” position the internal battery is connected to the units clock chip. If power is ever removed the battery will ensure the clock chip continues to run and therefore keep the current time. NOTE : This battery does not provide backup power to the entire A 1708 unit. The display will not light up and the unit will not function. Only the internal clock chip will still be supplied power. If the entire A 1708 requires backup power a backup power supply can be connected to the 24V DC input.
Redback® Proudly Made In Australia
10
Fig 5.1
5.0 BATTERY BACKUP
Inside the unit is the battery used to backup the internal clock chip. If DIP switch 1 is set to “ON” and the unit fails to keep the correct time after a power failure then it may be possible that the backup battery is at. To replace the battery, remove the lid and use a CR2032 battery (such as Altronics S 4999A) as the replacement. The location of the battery is shown in Fig 5.1.
Switch 2 - Station Edit Lockout
When switch 2 is set to “ON” access to the Station Edit Mode will be restricted. Therefore there can be no tampering of the Station (Event) times.
Switch 3 - Time Edit Lockout
When switch 3 is set to the “ON” access to the Time Edit Mode will be restricted. Therefore there can be no changes made to the current time.
Switch 4 - Clear Memory Lockout
When switch 4 is set to the “ON” access to the Clear Memory Mode will be restricted. Therefore there can be no erasing of the Station (Event) times stored in memory.
6.0 REAR CONNECTIONS
6.1 24V DC Connectors
DC sockets have been provided for 24V DC input and a 24V DC output. These two sockets are connected in parallel inside the unit, so either could be used as an input or output or both as inputs. Two sockets have been provided so that the power can be daisy chained to another device. The Altronics P 6717 DC power lead has been designed for this purpose. The sockets also have a threaded connector so that the Altronics P 0602 2.1mm DC Plug with collar can be screwed onto the DC socket so that the DC power lead cannot be accidentally pulled out.
Fig 6.1
6.2 DC Fuse
The A 1708 is tted with an M205 fuse holder with fuse rated at 2A.
6.3 Interface 1 and Interface 2
These are for future connection of product. Do not connect leads to these ports.
P 0602
2.1mm DC Plug with collar
The backup battery is located inside the unit and can be accessed by removing the lid.
Battery type CR2032 Altronics P/No: S 4999A
Redback® Proudly Made In Australia
11
Fig 6.5
6.4 Switched 24V Outputs:
These terminals have 24V DC present when the corresponding zone is set “ON”. These may be used to operate something like an external relay used to turn on a solenoid, a lunch bell, etc. (NOTE: The maximum current draw per output is about 120 milliamps (internally polyswitch protected), so it is advisable to run external 24V DC relays instead of trying to drive a 24V DC device directly from these outputs. See Fig 6.2 for an example of this).
6.5 Closing Contacts:
These contacts “close” when the output zone is set “ON”. These can be used to trigger devices such as the Altronics A 1741MP3 Message player.
Fig 6.5 demonstrates an example of how to connect the A 1708 to the A 1741. A 24V DC plugpack is used to power the A 1708, the 24V DC output of the timer is then fed into the A 1741 using a power lead with 2.1mm DC connectors such as the Altronics P 6717. Thus removing the need for another plugpack to power the message player. The Zone 1 switched output of the timer is then used to trigger a 24V DC bell. As the current draw of the Bell is more than 120mA a relay board is used to switch an external power supply. The Altronics S 4444 24V Relay Board as shown is an inexpensive and easily installed option designed for this purpose. In the example shown the Zone Output 2 closing contact of the timer is connected to the Input 1 trigger of the message player. When Zone 2 is activated by the timer, message 1 of the message player will be played.
4
L
R
Line Out
12-30V DC
Switched
Out
12-30V DC
IN
1
www.altronics.com.au
Manufactured in Australia
By Altronic Distributors Pty. Ltd.
1 2 3 4 5 6 7 8
2
3567
8
Alert
Cancel
DIP Switch Settings
ON OFF
1
Triggers momentary Triggers alternate
2
Alert/Evac ON
Not Used
SW
TRIGGER OPERATION & ALERT/EVAC SETTINGS
DIP Switches
Evac
Triggers
Close
Contacts
to
Trigger
5
0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
6
0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
7
0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
8
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
Delay (Sec.)
OFF
306090
120
150
180
210
240
270
300
330
360
390
420
450
AUTO ALERT TO EVAC SWITCHOVER TIMER SETTINGS. 0 = OFF. 1 = ON.SW
3
Front switches active Front switches de-activated
4
Alert/Evac OFF
+
+
-
1 2 3 4 5 6 7 8
24V Bell
(eg school bell, lunch bell etc)
24V DC Plugpack
(such as Altronics M 9391A)
24V DC Power lead
(such as Altronics P 6717)
(Not supplied)
A 1708
50 EVENT TIMER
A 1741
MP3 Message Player
+24V
GND
24V Relay Board
(Altronics S 4444)
N/C1
N/C2
N/O2
N/O1
COM1
COM2
External
24V DC Supply
+24V
GND
24VDC
Input
24VDC Output
4 3 2 1
4 3 2 1
24V Switched Out
DIP Switch Settings
SW ON
1 2
Station Edit Lockout Enabled
3
Edit Time Lockout Enabled
4
Clear Memory Lockout Enabled
Battery Backup On
www.altronics.com.au
Manufactured in Australia By Altronic Distributors Pty. Ltd.
DIP Switches
Interface 1 Interface 2DC Fuse
M205 2 Amp
+
+
_
_
+-
+
+
_
_
+-
1 2 3 4 5 6 7 8
Redback® Proudly Made In Australia
12
STATION OUTPUT DAY TURN ON TIME DURATION TURN OFF TIME
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30 31 32 33
34 35 36 37 38 39 40 41 42
43 44 45 46 47
48 49
50
OUTPUT 1 =
OUTPUT 2 =
OUTPUT 3 = OUTPUT 4 =
7.0 EVENT TIMES RECORD
A sheet has been provided to record all of the Event(s) information for easy reference.
Loading...