REDARC solar regulators ensure that the power supplied by your solar panels is at the right voltage to charge
your lead acid house or auxiliary batteries. REDARC solar regulators are Pulse Width Modulated (PWM)
controlled and incorporate automatic system voltage detection.
Redarc solar regulators come in 10A, 20A and 30A models which are capable of charging either 12V or 24V
battery systems.
Redarc Solar Regulators use genuine Anderson™ SB™50 connectors.
The SRPA regulators are supplied factory set to the AGM battery type setting; A REDARC remote monitor
(SRPA-RM) is required to change the battery type.
WARNING & SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS - This manual contains IMPORTANT SAFETY INSTRUCTIONS for REDARC
Solar Regulators.
DO NOT OPERATE THE SOLAR REGULATOR UNLESS YOU HAVE READ AND UNDERSTOOD THIS MANUAL
AND THE SYSTEM IS SETUP AS PER THESE INSTRUCTIONS. REDARC RECOMMENDS THAT ANY
REGULATOR/CHARGER BE INSTALLED BY A SUITABLY QUALIFIED PERSON.
RISK OF EXPLOSIVE GASES:
WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE
GASES DURING NORMAL OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT YOU
FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE REGULATOR.
1. Solar Regulators should not be used by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they are supervised or have been
instructed on how to use the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the Solar Regulator.
2. Do NOT use the Solar Regulator to charge non-rechargeable batteries. Doing so may result in harm to
the user and/or damage to the regulator and/or solar blanket. Only use the Solar Regulator for charging
standard lead acid, calcium content, Gel & AGM type 12V batteries.
3. Over Charging Hazard. Failure to connect solar panel’s negative wire directly to the regulator may result
in overcharging the battery. The solar panel’s negative wire must be connected direct to the regulator
only.
4. Check the battery manufacturer’s data for your battery and ensure that the voltage of the charging
profi le you select does not exceed the manufacturer’s recommended maximum charging voltage. If the
‘Absorption’ voltage for your battery type is too high, please select another charging profi le. The Solar
Regulator is not intended to supply power to a low voltage electrical system other than to charge a
battery.
5. Electrical Hazard. Incorrect connection of batteries and solar panels in Parallel or Series can subject
the regulator to high voltages that will damage the regulator. Ensure the recommended connections
and sequences are followed and that the rated current and/or wattage of the regulator is not exceeded.
SAL.FOR.Instruction Manual Solar Regulators – DOC393 – Version 5
1
Page 3
WARNING & SAFETY INSTRUCTIONS
6. NEVER smoke or allow a spark or fl ame in vicinity of battery or engine. This may cause the battery to
explode.
7. PERSONAL SAFETY PRECAUTIONS
To assist with the safe operation and use of the Solar Regulator:
a) Wear complete eye protection and clothing protection. Avoid touching eyes while working near a battery.
b) If battery acid contacts your skin or clothing, remove the affected clothing and wash the affected area
of your skin immediately with soap and water. If battery acid enters your eye, immediately fl ood the eye
with running cold water for at least 10 minutes and seek medical assistance immediately.
1. The Solar Regulator will achieve best results when proper battery maintenance is regularly performed.
This includes but is not limited to checking water and specifi c gravity levels of the battery.
CONTENTS
The Solar Regulator 1
Warning & Safety Instructions 1
Contents 2
1. Introduction 3
1.1. Dimensions 3
1.2. Regulator Function 3
2. The Solar Regulator 4
2.1. Regulator Connection 4
2.2. LED Indication 4
2.3. Specifi cations 5
3. System Setup 6
3.1. Installation Notes 6
3.2. Fuse Protection 7
3.3. Accessories 8
3.3.1. SRPA-RM 8
3.3.2. REDARC Cable Range 8
4. System Wiring 9
4.1. 12V Standard System 9
4.2. 24V Standard System 10
4.3. Wiring Multiple Panels 12V 11
4.4. Wiring Multiple Panels 24V 12
2
Page 4
1 INTRODUCTION
1.1 DIMENSIONS
153 mm
135 mm
98 mm (SRPA0120)
103mm (SRPA0240)
108mm (SRPA0360)
28 mm
1.2 REGULATOR FUNCTION
The SRPA regulators are supplied factory set to the AGM battery type setting; A REDARC remote monitor
(SRPA-RM) is required to change the battery type.
Solar Panel LED1
Indicator
Battery LED2
Indicator
Battery Output
Solar Panel Input
RJ45 Remote Monitor
Connector
RJ45 Connector Cap
3
Page 5
2. THE SOLAR REGULATOR
2.1 REGULATOR CONNECTION
Connect to the Battery and Solar Panel via an Anderson™ SB™50, 50A grey connector.
Connect to the battery fi rst before the solar panel.
The REDARC Solar Regulator should be connected as close as possible to the battery it is charging.
Refer to section 3.1 Installation notes and section 4. System Wiring.
Caution: Incorrect connection of the battery or solar panel can damage the regulator, please confi rm all
wiring polarity before connection is made.
2.2 LED INDICATION
LED StatusOn Solid1 fl ash/secondOff3 fl ashes/second
LED1 - Solar panel (Green)NormalChargingNo ChargeN/A
LED2 - Battery (Green)NormalBattery FullN/AOver voltage
LED2 - Battery (Red)Over Discharge
N/A
LED2 - Battery (Orange)Under Voltage
LED1 - Green
LED2 - Red
LED1 - Green
LED2 - Orange
LED1 fl ashing green - 1 fl ash/second
The regulator is charging the battery and all
functions are normal.
LED2 fl ashing green - 1 fl ash/second
The battery is full and all functions are normal.
LED1 off
There is no charge from the solar panel. Check the
solar panel is connected correctly and the panel is
in full sunlight.
LED2 solid green
The battery is connected and the voltage range is
normal.
System voltage error
N/A
Over temperature
Solar Panel LED1
Indicator
Battery LED2
Indicator
LED1 Green & LED2 Red - 3 fl ashes/second
The regulator has a solar panel or battery
connected producing a voltage outside the system
limits, please remove and check the solar panel or
battery voltage.
LED2 solid red
The battery has experienced a high rate of
discharge and the regulator has stopped charging,
check battery charge level and loads connected.
LED2 solid orange
The battery voltage is low.
LED1 Green & LED2 orange - 3 fl ashes/second
The regulator internal temperature has exceeded
80°C and will stop charging until the temperature is
reduced.
4
Page 6
2 THE SOLAR REGULATOR
2.3 SPECIFICATIONS
System Voltage12V24V
Battery Type
selectable via remote
monitor SRPA-RM
Absorption Voltage*
Constant Current Stage
Equalize Charging
Voltage
Equalise Time
Absorb Time
Float Voltage*
Solar Panel Input Range
Battery Voltage Range
Standby Current Draw
Battery Charging Limit
Voltage
AGM
StandardCalcium
(Default)
14.4V14.6V14.8V28.8V29.2V29.6V
14.8V15V
n/a
2 hours2 hours
3 hours
13.6V27.2V
16V - 32V34V - 50V
9V -16V18V - 32V
10mA4.5mA
16V32V
AGM
StandardCalcium
(Default)
29.6V30V
n/a
Boost Reconnect
Charging Voltage
Power Rating
Current Limit
Boost Charge
Charge Type and Operating
Frequency
Charging Stage Switching
Temp. Compensation
Terminals
Connector
Waterproof / IP Rating
13.2V26.4V
120W (SRPA0120)
240W (SRPA0240)
360W (SRPA0360)
10A (SRPA0120) / 20A (SRPA0240) / 30A (SRPA0360)
100% of available solar charge will be used until absorption voltage is
reached.
PWM 50Hz
Switches on voltage setting
-3mV/°C at 2V
Anderson™ Powerclaw™, 50A
Anderson™ SB™50, Grey
Yes / IP 55
240W (SRPA0120)
480W (SRPA0240)
720W (SRPA0360)
Operating Temp.
*Charge profi le voltages will change with temperature compensation
-35°C to 55°C
5
Page 7
3 SYSTEM SETUP
3.1 INSTALLATION NOTES
• Always connect the battery/s fi rst (before the panel).
• Always ensure the connection to the battery terminals is sound, with as much surface contact
between the battery terminal and the connection method (e.g. Alligator clips) as possible.
• The regulator should be installed as close as possible to the battery/s.
• Ensure that any non-Redarc Anderson™ plug terminals are soldered correctly or crimped with the
correct Anderson™ crimping tool.
• Always check the manufacturer’s data for your battery and ensure that the ‘Maximum’ voltage of the
charging profi le you select does not exceed the manufacturer’s recommended maximum charging
voltage. If the ‘Maximum’ voltage for your battery type is too high, please select another charging
profi le. SRPA-RM will be required to change from default setting.
• Care should be taken to not expose the regulator to moisture.
• For optimum operation, the regulator should be mounted in an environment where the temperature
is normally below 45°C and does not exceed 55°C.
• Battery clip SRC0009 is intended for a portable short term connection and should not to be left
connected permanently.
OVER CHARGING HAZARD. FAILURE TO CONNECT SOLAR PANEL’S NEGATIVE WIRE DIRECTLY TO THE
REGULATOR MAY RESULT IN OVERCHARGING THE BATTERY. THE SOLAR PANEL’S NEGATIVE WIRE
MUST BE CONNECTED DIRECT TO THE REGULATOR ONLY.
ELECTRICAL HAZARD. INCORRECT CONNECTION OF BATTERIES AND SOLAR PANELS IN PARALLEL
OR SERIES CAN SUBJECT THE REGULATOR TO HIGH VOLTAGES THAT WILL DAMAGE THE
REGULATOR. ENSURE THE RECOMMENDED CONNECTIONS AND SEQUENCES ARE FOLLOWED AND
THAT THE RATED CURRENT AND/OR WATTAGE OF THE REGULATOR IS NOT EXCEEDED.
--
6
Page 8
3 SYSTEM SETUP
3.2 FUSE PROTECTION
Fuse protection is required for wire and component protection in case of short circuit. Fuses are to
be fi tted as close as possible to the battery positive terminal.
REDARC recommend using MIDI style bolt down fuses as they ensure a low resistance connection.
The REDARC FK40 and FK60 fuse kits are recommended.
Blade type fuses are not recommended as they can result in high resistance connection which
causes excess heat and may damage the fuse holder and/or the wiring. Self-resetting circuit
breakers are not recommended as they may trip prematurely due to the heat generated by the
current fl owing through the wires.
7
Page 9
3 SYSTEM SETUP
3.3 ACCESSORIES
3.3.1 SRPA-RM
The SRPA-RM is an optional Remote Monitor for use with REDARC SRPA0120, SRPA0240 and
SRPA0360 regulators.
The SRPA-RM is required to change the charging profi le on the Regulator. By Default SRPA0120,
SRPA0240 and SRPA0360 Regulators are set to AGM.
3.3.2 REDARC CABLE RANGE
Part NumberLengthDescription
SRC000710mAnderson™ to Anderson™ Cable
SRC00081.5mAnderson™ to Anderson™ Cable
SRC00091.5mAnderson™ to Battery Clip
SRC00101.5mAnderson™ to Battery Terminal
SRC0011Series Anderson™ to Anderson™ Connector
SRC0012Parallel Anderson™ to Anderson™ Connector
SRC00145mAnderson™ to Anderson™ Cable
8
Page 10
4 SYSTEM WIRING
4.1 12V STANDARD SYSTEM
Optional Remote Monitor
Solar Regulator
or Blanket
Solar Panel
1.5m SRC0009
or SRC0010
10m SRC0007,
1.5m SRC0008 or
5m SRC0014
-
9
Page 11
4 SYSTEM WIRING
4.2 24V STANDARD SYSTEM
in series
Solar Panels or Blankets
SRC0011
Series Cable
see Redarc FK40
10m SRC0007,
1.5m SRC0008 or
5m SRC0014
30A
Fuse Ratings:
Regulator Fuse Size
SPRA0120 15A
SPRA0240
SPRA0360 40A
must be used and should be determined according
Fuses are not supplied.
For other installations, appropriate sized fuses
-
Solar RegulatorOptional Remote Monitor
1.5m SRC0010
or SRC0009
10
-
Fuse
Page 12
4 SYSTEM WIRING
4.3 WIRING MULTIPLE PANELS IN PARALLEL (12V)
SRC0012
Parallel Cable
see Redarc FK40
10m SRC0007,
1.5m SRC0008 or
5m SRC0014
30A
Fuse Ratings:
Regulator Fuse Size
SPRA0120 15A
SPRA0240
SPRA0360 40A
must be used and should be determined according
Fuses are not supplied.
For other installations, appropriate sized fuses
Solar RegulatorOptional Remote MonitorSolar Panels in Parallel
1.5m SRC0010
or SRC0009
11
-
Fuse
Page 13
4 SYSTEM WIRING
4.4 WIRING MULTIPLE PANELS OF DIFFERENT TYPES IN PARALLEL (12V)
SRC0012
Parallel Cable
10m SRC0007,
1.5m SRC0008 or
5m SRC0014
30A
Fuse Ratings:
Regulator Fuse Size
SPRA0120 15A
SPRA0240
see Redarc FK40
SPRA0360 40A
must be used and should be determined according
Fuses are not supplied.
For other installations, appropriate sized fuses
-
Solar RegulatorOptional Remote MonitorSolar Panels in Parallel
1.5m SRC0010
or SRC0009
12
Fuse
Page 14
REDARC SOLAR PRODUCT WARRANTY
Over the last three decades our company has established a reputation as the power conversion specialist.
A 100% Australian-owned company, we have met the needs of customers in transport and other industries through exciting, innovative thinking.
We believe in total customer satisfaction and practice this by offering our customers:
• Technical advice free of jargon and free of charge
• Prompt turnaround of orders throughout Australia and globally
• Friendly, personalised, professional service and product support
In the unlikely event that a technical issue arises with a Redarc product, customers are encouraged to initially contact the Redarc Technical
Support Team on (08) 8322 4848 or
power@redarc.com.au
for prompt and effi cient diagnosis and product support.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major
failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail
to be of acceptable quality and the failure does not amount to a major failure.
The benefi ts of this Warranty are in addition to other rights and remedies available at law in respect of the Solar Products and shall not derogate from any
applicable mandatory statutory provisions or rights under the Australian Consumer Law.
Redarc Electronics Pty Ltd atf the Redarc Trust trading as Redarc Solar (“
Redarc
”) offers a warranty in respect of its Solar Products where the Solar Products
are purchased from an authorised Redarc Solar distributor or reseller by a person (“
Purchaser
”), on the terms and conditions, and for the duration, outlined
below in this document (“
Warranty
”).
Over the last three decades our company has established a reputation as the power conversion specialist.
A 100% Australian-owned company, we have met the needs of customers in transport and other industries through exciting, innovative thinking.
We believe in total customer satisfaction and practice this by offering our customers:
• Technical advice free of jargon and free of charge
• Prompt turnaround of orders throughout Australia and globally
• Friendly, personalised, professional service and product support
In the unlikely event that a technical issue arises with a Redarc product, customers are encouraged to initially contact the Redarc Technical
Support Team on (08) 8322 4848 or
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major
failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail
to be of acceptable quality and the failure does not amount to a major failure.
The benefi ts of this Warranty are in addition to other rights and remedies available at law in respect of the Solar Products and shall not derogate from any
applicable mandatory statutory provisions or rights under the Australian Consumer Law.
Redarc Electronics Pty Ltd atf the Redarc Trust trading as Redarc Solar (“
are purchased from an authorised Redarc Solar distributor or reseller by a person (“
below in this document (“
Warranty
power@redarc.com.au
”).
for prompt and effi cient diagnosis and product support.
Redarc
”) offers a warranty in respect of its Solar Products where the Solar Products
Purchaser
”), on the terms and conditions, and for the duration, outlined
1. In this Warranty, the term Solar Products means:
1.1 Redarc Solar Monocrystalline Solar Panels;
1.2 Redarc Solar Monocrystalline Folding Portable Solar Panel Kits;
1.3 Redarc Solar Monocrystalline Folding Solar Panels;
1.4 Redarc Solar Amorphous Flexible Solar Panels;
1.5 Redarc Solar Amorphous Folding Solar Panels;
(collectively the “Modules”);
1.6 Redarc Solar Regulators and Displays;
1.7 all other solar products manufactured or supplied by Redarc
that are designed for use in recreational vehicles and boats, not
otherwise specifi cally referred to in this clause 1; and
1.8 any component of or accessory for any product in clause 1.1 to
1.7 (inclusive) manufactured or supplied by Redarc.
Offer and duration of product warranties
2. Subject to this clause 2, Redarc warrants that its Solar Products will be
free, under normal application, installation, use and service conditions,
from defects in materials and workmanship affecting normal use, for
the relevant periods set out below:
2.1 Redarc Solar Monocrystalline Solar Panels – 5 years from the
date of purchase;
2.2 Redarc Solar Monocrystalline Folding Portable Solar Panel Kits –
5 years from the date of purchase;
2.3 Redarc Solar Monocrystalline Folding Solar Panels – 2 year from
the date of purchase;;
2.4 Redarc Solar Amorphous Flexible Solar Panels – 2 years from the
date of purchase;
2.5 Redarc Solar Amorphous Folding Solar Panels – 2 years from the
date of purchase;
2.6 Redarc Solar Regulators and Displays – 2 years from the date of
purchase; and
2.7 all other Solar Products not otherwise set out in this clause 2 – 2
years from the date of purchase.
3. Where a Solar Product malfunctions (excluding as a result of a
reduction in power output levels, which is the subject of clause 4) or
becomes inoperative during the relevant warranty period applicable to
that Solar Product pursuant to clause 2, due to a defect in materials or
workmanship, as determined by Redarc, then subject to further rights
conferred by the Australian Consumer Law on the Purchaser, Redarc
will, in exercise of its sole discretion, either:
3.1 repair the defective Solar Product;
3.2 replace the defective Solar Product; or
3.3 provide a refund to the Purchaser for the purchase price paid for
the defective Solar Product,
without charge to the Purchaser.
4. Redarc warrants that:
4.1 if any Redarc Solar Monocrystalline Solar Panels or any Redarc
Solar Monocrystalline Folding Portable Solar Panel Kits exhibit a
power output of less than 80% of Peak Power under Standard
Test Conditions, within 25 years of the date of purchase;
4.2 if any Redarc Solar Monocrystalline Folding Solar Panels, Redarc
Solar Amorphous Flexible Solar Panels or any Redarc Solar
Amorphous Folding Solar Panels exhibit a power output of less
than 80% of Peak Power under Standard Test Conditions, within
5 years of the date of purchase;
and such loss of power is determined by Redarc to be due to a
defect in materials or workmanship, then subject to further rights
conferred by the Australian Consumer Law on the Purchaser,
Redarc will, in exercise of its sole discretion, either:
4.3 make up the loss in power by supplying the Purchaser with
relevant additional Modules; or
4.4 repair or replace the defective Modules, without charge to the
Purchaser.
5. For the purposes of clause 4:
5.1 Peak Power means the minimum peak power level in Watts that
a Module generates in its maximum power point (as stated on the
label affi xed to the Module or on the product information sheet
accompanying the Module); and
5.2 Standard Test Conditions means:
(a) light spectrum of AM 1.5;
(b) an irradiation of 1,000 Watts per square metre; and
(c) a cell temperature of 25 degrees centigrade at right angle
irridation,
the measurements being carried out in accordance with
IEC61215 as tested at the connectors or junction box terminals
(as applicable) per the calibration and testing standards of Redarc
in effect on the date of manufacture of the Module.
6. The warranties given by Redarc in clauses 2 to 4 cover the reasonable
costs of delivery and installation of any repaired or replaced Solar
Products or components of Solar Products to the Purchaser’s usual
residential address notifi ed to Redarc, together with the reasonable
costs of removal and return of any Solar Products determined by
Redarc to be defective.
7. If the Purchaser incurs expenses of the nature referred to in clause 6 in
the context of making a claim pursuant to this Warranty that is accepted
by Redarc, the Purchaser will be entitled to claim for reimbursement of
those expenses which Redarc determines, in exercise of its sole
Page 15
discretion, to be reasonably incurred, provided that the claim is notifi ed
to Redarc in writing at the postal address or email address specifi ed in
clause 23 and includes:
7.1 details of the relevant expenses incurred by the Purchaser; and
7.2 proof of the relevant expenses having been incurred by the
Purchaser.
Exclusions and limitations
8. This Warranty will not apply to, or include any defect, damage, fault,
failure or malfunction of a Solar Product, which Redarc determines to
be due to:
8.1 normal wear and tear or exposure to weather conditions over
time;
8.2 accident, misuse, abuse, negligence, vandalism, alteration or
modifi cation;
8.3 non-observance of any of the instructions supplied by Redarc,
including instructions concerning installation, confi guring,
connecting, commissioning, use or application of the Solar
Product, including without limitation choice of location;
8.4 failure to ensure proper maintenance of the Solar Product strictly
in accordance with Redarc’s instructions or failure to ensure
proper maintenance of any associated equipment or machinery;
8.5 repairs to the Solar Product that are not strictly in accordance
with Redarc’s instructions;
8.6 installation, repairs or maintenance of the Solar Product by, or
under the supervision of, a person who is not a qualifi ed auto
electrician or technician, or if non-genuine or non-approved parts
have been fi tted;
8.7 faulty power supply, power failure, electrical spikes or surges,
lightning, fl ood, storm, hail, extreme heat, fi re or other occurrence
outside the control of Redarc;
8.8 use other than for any reasonable purpose for which the Solar
Product was manufactured;
8.9 any indirect or incidental damage of whatever nature outside the
control of Redarc.
9. Warranty claims in respect of a Solar Product must be made in writing
to Redarc at the postal address or email address specifi ed in clause
23 within the relevant warranty period applicable to that Solar Product
pursuant to clause 2 or clause 4. Such claims must include the
following:
9.1 details of the alleged defect or fault and the circumstances
surrounding the defect or fault;
9.2 evidence of the claim, including photographs of the Solar Product
(where the subject of the claim is capable of being photographed);
9.3 the serial number of the Solar Product, specifi ed on the label
affi xed to the Solar Product; and
9.4 proof of purchase documentation for the Solar Product from an
authorised distributor or reseller of Redarc, which clearly shows
the date and place of purchase.
The return of any Solar Products without the prior written instructions of
Redarc will not be accepted by Redarc.
10. Without limiting any other clause in this Warranty, Redarc has the right
to reject any warranty claim made by a Purchaser pursuant to this
Warranty where:
10.1 the Purchaser does not notify Redarc in writing of a warranty
claim within relevant warranty period applicable to that Solar
Product;
10.2 the Purchaser does not notify Redarc in writing of a warranty claim
within 1 month of becoming aware of the relevant circumstances
giving rise to the claim, so that any further problems with the
Solar Product are minimised;
10.3 the serial number of the Solar Product has been altered, removed
or made illegible without the written authority of Redarc;
10.4 the Purchaser is unable to provide proof of purchase
documentation in accordance with clause 9.4 or evidence
that the Solar Product was properly installed, and that proper
maintenance has been performed on the Solar Product, by, or
under the supervision of, a qualifi ed auto electrician or technician,
in accordance with the instructions of Redarc.
11. If the Solar Product is found to be working satisfactorily on return
to Redarc or upon investigation by Redarc, the Purchaser must pay
Redarc’s reasonable costs of testing and investigating the Solar
Product in addition to shipping and transportation charges. Where
Redarc is in possession of the Solar Product, the Solar Product will be
returned to the Purchaser on receipt of the amount charged.
12. Any replaced Solar Products or components of Solar Products shall
become the property of Redarc.
13. Redarc may, in exercise of its sole discretion, deliver another type
of Solar Product or component of a Solar Product (different in size,
colour, shape, weight, brand and/or other specifi cations) in fulfi lling
its obligations under this Warranty, in the event that Redarc has
discontinued manufacturing or supplying the relevant Solar Product
or component at the time of the warranty claim, or where such Solar
Product or component is superior to that originally purchased by the
Purchaser.
Other conditions of Warranty
14. If the Purchaser acquired a Solar Product for the purpose of resupply,
then this Warranty shall not apply to that Solar Product.
15. In particular, the sale of a Solar Product via an online auction, online
store or other internet website by a party that is not an authorised
distributor or reseller of the Solar Product will be deemed to be a
resupply within the meaning of the Australian Consumer Law and will
render this Warranty void, as Redarc has no control over the storage,
handling, quality or safety of Solar Products sold by such persons.
16. A Purchaser shall only be entitled to the benefi t of this Warranty after all
amounts owing in respect of the Solar Product have been paid.
17. While Redarc warrants that the Solar Products will be free from defects
in materials and workmanship in the circumstances set out in this
Warranty, to the maximum extent permitted by law Redarc does not
warrant that the operation of the Solar Products will be uninterrupted or
error-free.
18. To the maximum extent permitted by law, Redarc’s determination of the
existence of any defect and the cause of any defect will be conclusive.
19. Spare parts or materials for the Solar Products are guaranteed to be
available for a period of at least 2 years after purchase of the Solar
Products.
20. The agents, offi cers and employees of any distributor or reseller of the
Solar Products and of Redarc are not authorised to vary or extend the
terms of this Warranty.
21. Redarc shall not be responsible or liable to the Customer or any third
party in connection with any non-performance or delay in performance
of any terms and conditions of this Warranty, due to acts of God, war,
riots, strikes, warlike conditions, plague or other epidemic, fi re, fl ood,
blizzard, hurricane, changes of public policies, terrorism and other
events which are beyond the control of Redarc. In such circumstances,
Redarc may suspend performance of this Warranty without liability for
the period of the delay reasonably attributable to such causes.
22. If a clause or part of a clause in this Warranty can be read in a way
that makes it illegal, unenforceable or invalid, but can also be read
in a way that makes it legal, enforceable and valid, it must be read
in the latter way. If any clause or part of a clause in this Warranty is
illegal, unenforceable or invalid, that clause or part is to be treated
as removed from this Warranty, but the rest of this Warranty is not
affected.
Redarc’s contact details
23. Redarc’s contact details for the sending of warranty claims under the
Warranty are:
This product has been specifi ed and tested in Australia in accordance with REDARC specifi cations and
testing requirements by REDARC Engineers. You can be assured that this product meets the stringent
quality levels of all REDARC products.