Rectorseal NoKink Installation Manual

Flexible refrigerant line connector.
7/8"
5/8"
1/2"
1/4"
3/8"
• Eliminates kinking of copper refrigerant tubing when wall-mounting mini-split evaporators.
• 3" and 6' lengths • Easy aring • Quick connection
Code Description Qty.
66731 1/4" x 3'ex hose 4 66733 3/8" x 3'ex hose 4 66737 1/2" x 3'ex hose 4 66735 5/8" x 3'ex hose 4 66732 3/4" x 3'ex hose 4 66734 7/8" x 3'ex hose 4
68231 1/4" x 6'ex hose 4 68233 3/8" x 6'ex hose 4 68235 5/8" x 6'ex hose 4 68237 1/2" x 6'ex hose 4
Equivalent Length Chart
Product
Code
NoKink
Dia/Length
Equivalent Length
of copper tubing
66731 1/4" x 3' 7.7' (EL) 66733 3/8" x 3' 7.9' (EL) 66737 1/2" x 3' 5.1' (EL) 66735 5/8" x 3' 3.7' (EL) 66732 3/4" x 3' 4.6' (EL) 66734 7/8" x 3' 5' (EL)
68231 1/4" x 6' 12' (EL) 68233 3/8" x 6' 10.1' (EL) 68237 1/2" x 6' 10.1' (EL) 68235 5/8" x 6' 8.4' (EL)
RectorSeal NoKink
Flexible mini-split refrigerant line connector
FEATURES
Eliminates kinking of refrigerant line • Stainless steel internal piping and jacketing • 3" copper stubs
allow for easy aring and
quick connections
INSTALLATION INSTRUCTIONS
Application
Corrugated stainless steel flexible piping, protected with woven stainless steel jacketing, connects evaporator units to linesets quickly and easily Eliminate kinks and refrigerant leaks Allows for ease of future maintenance UL listed for R410A Available in both 36" and 72" overall length 3" copper stub length 10 sizes available
NOTE: Insulate per local code.
RectorSeal, the logos and other trademarks are property of RectorSeal, LLC, its affiliates or its licensors and are protected by copyright, trademark and other intellectual property laws, and may not be used without permission.
(1) Attach the RectorSeal NoKink
connector to the refrigerant line in the mini-split evaporator unit using either silver solder or flaring. Warning: The excessive heat during soldering or brazing
could damage the NoKink hose and cause a leak. A heat blocking
product, such as RectorShield or Hot Block, shall be used during soldering or brazing to protect NoKink hoses. (2) Pull the in-wall copper refrigerant line through wall opening and attach it to the other end of the NoKink connector. (3) Feed the in-wall copper refrigerant line and flexible NoKink connector back up into the wall opening, and mount the evaporator to the mounting bracket.
Use the Equivalent Length Chart to calculate Nokink flexible hose refrigerant capacity when determining proper charging of the system.
EXAMPLE: If the copper lineset length measures 33 linear feet, and the Nokinks used are 1/4" x 3
' and 1/2" x 3'
First, average the equivalent lengths (EL) of both NoKinks: 1/4" x 3 1/2" x 3 Average = 6.4
Next, add 6.4 Total lineset length = 39.4
' Nokink = 7.7' (EL) ' Nokink = 5.1' (EL)
' (EL)
' (EL) to the 33 linear feet of copper lineset.
'
Then, use the total lineset length (in this case, 39.4 referring to manufacturers specifications to calculate the amount of additional refrigerant that may be needed for
proper charging.
2601 Spenwick Drive - Houston, TX 77055 800-231-3345 rectorseal.com
RectorSeal reserves the right to change specifications without prior notice. © 2018 RectorSeal. All rights reserved. R50048-0718
') when