Rectorseal EZT 180 Installation Manual

961736
0 2 1 4 4 9 8 3 1 8 0 2
www.rectorseal.com
, that it is free from defects in material or workmanship. If within two years
warrants to the original consumer purchaser (”Purchaser”)
®
®
2601 Spenwick Drive, Houston, TX 77055 (800) 231-3345
®
any other consequential damages. The sole liability of the manufacturer under this warranty
replacement labor or any cost, claim or incident to any defect nor does it cover freezing or of purchase is required to determine warranty eligibility. This warranty does not cover be defective, it shall be repaired or replaced at RectorSeal’s option. Your original receipt
(24 months) from the date of the original consumer purchase this product shall prove to
RectorSeal
neglect, alteration, abuse or improper installation is excluded from this warranty.
is limited to the replacement of defective product. Product damaged by improper use, accident,
2 Year
of its product, EZ Trap
LIMITED WARRANTY. RectorSeal
U.S. Patent Numbers 5,069,042 5,522,229
Scan for more info
noise and insects. Permits free condensate ow while blocking odors, Use on any mini-split evaporator with gravity drain. Sized for use in ductless mini-split applications. Eliminates standing water and freezing problems.
EZT18 0
Product Code 83180
Mini Waterless In-Line Condensate Trap
Kit Contents
Mini Trap (1) Rubber Adapter (1) Cleaning Label (1)
Product Code 83180
EZT18 0
EZT18 0
TRAP MUST BE INSTALLED VERTICALLY – WIDE END UP AND NARROW END DOWN, FOR CONDENSATE TO FLOW. INCORRECT INSTALLATION WILL CAUSE BACK-UP OF CONDENSATE.
To ensure proper condensate drainage:
• The drain hose must exit the mini-split with a slope
• Tr ap must be installed a minimum of 12” below the unit
• Trap must be installed vertically (wide end up)
• Where possible, install Trap within 6 ft. of ground to facilitate inspection and cleaning.
INSTALLATION INSTRUCTION:
1. Insert the end of inlet drain hose into the top of the
Trap (Wide End) and seat firmly. Note: Trap fits 5/8” (16mm) inlet drain hose snuggly. (A) Use Rubber Adapter (provided) when using 9/16” (14mm) inlet drain hose only. (B)
2. Insert end of outlet drain hose into the bottom of Trap (Narrow End) and seat firmly. (C)
3. Wrap inlet and outlet connection with PVC Tape. (D) DO NOT GLUE THE TRAP
4. Fit Hose/Trap assembly to wall with 2 pipe brackets 3” from Trap. NOTE: Ensure that Black Valve Assembly is perpendicular to or facing away from wall to
facilitate cleaning. (E)
Maintenance:
• Clean Trap annually or more often if required.
• Ensure that bleed holes of the Trap are not blocked.
• Remove Trap before cleaning cooling coil with chemical cleaner.
Important:
Install in accordance with RectorSeal
instructions as well as all applicable local plumbing and drainage codes.
• Use EZT180 with mini-split air conditioner applications only.
• EZT180 is designed for use with non­ kinking corrugated PE Drain Hose (DH-16). Thin wall vinyl hose kinks easily and should not be used for this application.
• Tr ap is not required if condensate pump is fitted.