RECREUS FilaFlex MEDIUM FLEX 95A Service Manual

RECREUS INDUSTRIES S.L. VAT: ESB54876479 C/PICO VELETA, 36 03600 ELDA (ALICANTE) SPAIN
info@recreus.com www.recreus.com
tel: 0034 865 777 966
Filaflex®MEDIUM FLEX 95A
PHYSICAL PROPERTIES
TYPICAL VALUE
Test method
Density
1,15 g/cm³
ISO 1183-1-A
Hardness Shore A
95
ISO 7619-1
Elongation at break
540%
ISO 37
Tensile strength
55 Mpa
ISO 37
Abrasion loss
25mm³
ISO 4649-A
Flammability rating
HB
UL 94
PRINTING PROPERTIES
VALUE
Printing Temperatures
215-235°C
Printing Speed
20-40 mm/s
Hot-Bed temperature
40 °C
Optimal layer height
0,2mm
Minimal Nozzle diameter
0,3MM (0,4mm or higher recommended)
Rectraction parameters
3,5-6,5 mm (speed 20-160 mm/s)
RECREUS INDUSTRIES S.L. VAT: ESB54876479 C/PICO VELETA, 36 03600 ELDA (ALICANTE) SPAIN
info@recreus.com www.recreus.com
tel: 0034 865 777 966
FILAFLEX ® ORIGINAL MSDS
1. PRODUCT AND COMPANY IDENTIFICATION
1.1 TRADE NAME: FilaFlex®MEDIUM FLEX 95A
1.2 COMPANY DETAILS:
RECREUS INDUSTRIES S.L.
C/PICO VELETA, 36
03600 ELDA, (Alicante), SPAIN
Tel: 0034 865 777966
info@recreus.com www.recreus.com
2. HAZARDS IDENTIFICATION
Not a product dangerous for health or the environment according to the definition of EC
directives
2006/121/EC or
1999/45/EC and their valid adaptations and derived national
regulations.
3. COMPOSITION/INFORMATION ON INGREDIENTS
Polyurethane Thermoplastic – 97% CAS: 75701-44-9
1
RECREUS INDUSTRIES S.L. VAT: ESB54876479 C/PICO VELETA, 36 03600 ELDA (ALICANTE) SPAIN
info@recreus.com www.recreus.com
tel: 0034 865 777 966
4. FIRST AIDS
1. General instruction: Change clothes impregnated with the product.
2. In case of inhalation: Supply fresh air. In case of disturbances, consult
a doctor.
3. After inhalation of decomposition products, breathe fresh air, rest,
seek medical help.
4. In case of skin contact: Wash with soap and water. Visit your doctor if
irritation continues skin.
5. After contact with molten product, cool rapidly with cold water. No
skin separating the solidified product. Call a doctor immediately.
6. In case of eye contact: Rinse opened eye for several minutes under
running water. If symptoms persist, consult a doctor. Remove contact lenses, if present and easy. Continue rinsing.
7. If swallowed: Rinse mouth and drink plenty of water. Do not induce
vomiting. Consult doctor in case of persistent symptoms.
5. FIRE-FIGHTING MEASURES
5.1 Suitable extinguishing media: Water, Foam, Dry chemical
5.2 Burning releases carbon monoxide, carbon dioxide, oxides of nitrogen and traces of hydrogen cyanide. In the event of fire and/or explosion do not breathe fume.
5.3 Firemen must wear self‐contained breathing apparatus.
5.4 Do not allow contaminated extinguishing water to enter the soil, groundwater or surface waters.