EC 42 www.recom-international.comAugust 2002
ECONOLINE - DC/DC-Converter
RXT & RYT Series, 1W, DIP14, Regulated, Isolated Outputs (Dual Output)
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Selection Guide
Part Part Input Output Output Ouput Efficiency
Number Number Voltage Voltage Voltage Current
DIP 14 SIP 7 (VDC) (V1VDC) (V2VDC) (mA) (%)
RXT-XX0505 RYT-XX0505 5, 9, 12, 15, 24 5 5 100/100 53
RXT-XX0909 RYT-XX0909 5, 9, 12, 15, 24 9 9 55/55 58
RXT-XX1212 RYT-XX1212 5, 9, 12, 15, 24 12 12 42/42 62
RXT-XX1515 RYT-XX1515 5, 9, 12, 15, 24 15 15 33/33 65
RXT-XX0524 RYT-XX0524 5, 9, 12, 15, 24 24 24 21/21 65
Input Voltage ±5%
Input Filter Capacitor Type
Output Voltage Accuracy ±5%
Line Voltage Regulation ±0.5% - ±1%
Load Voltage Regulation (20% to 100% full load) ±0.5% - ±1.0%
Ripple and Noise (20MHz limited) 100mV p-p max.
Efficiency at Full Load 50% min.
Isolation Voltage 1.000VDC min.
Isolation Resistance (Viso = 500VDC) 10 GΩ min.
Isolation Capacitance 40pF min./72pF max.
Outputs Isolation Voltage 1.000VDC min.
Short Circuit Protection 1 Second
Switching Frequency at Full Load 38kHz min. / 85kHz max.
Operating Temperature -25°C to +70°C (see Graph)
Storage Temperature -55°C to +125°C
Package Weight 2.9g
● Isolated Outputs
● Output/Output Isolation 1kVDC
● Power Sharing on Outputs
● UL 94V-0 Package Material
● No Heatsink Required
● Toroidal Magnetics
● No Extern. Components Required
● Input/Output Isolation 1kVDC
Features