EC 38 www.recom-international.comAugust 2002
Selection Guide
ECONOLINE - DC/DC-Converter
RX and RY Series, 1 Watt, DIP14/SIP7, Regulated (Single Output)
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Input Voltage ±5%
Input Filter Capacitor Type
Output Voltage Accuracy ±5%
Line Voltage Regulation ±1%
Load Voltage Regulation (10% to 100% full load) ±1%
Ripple and Noise Output 100mVp-p max.
Efficiency at Full Load 50% min.
Isolation Voltage 1.000VDC min.
Isolation Resistance (Viso = 500VDC) 10 GΩ min.
Isolation Capacitance 30pF min./150pF max.
Short Circuit Protection 1 Second
Switching Frequency at Full Load 30kHz min. / 88kHz max.
Operating Temperature -40°C to +71°C (see Graph)
Storage Temperature -55°C to +125°C
Package Weight RX types 2.9g
RY types 2.8g
Part Part Input Output Output Efficiency
Number Number Voltage Voltage Current
DIP14 SIP7 (VDC) (VDC) (mA) (%)
RX-XX05S RY-XX05S 5, 9, 12, 15, 24 5 180 58-60
RX-XX09S RY-XX09S 5, 9, 12, 15, 24 9 111 56-62
RX-XX12S RY-XX12S 5, 9, 12, 15, 24 12 84 60-66
RX-XX15S RY-XX15S 5, 9, 12, 15, 24 15 66 60-66
RX-XX24S RY-XX24S 5, 9, 12, 15, 24 24 42 60-68
● Load Voltage Regulation <1.5%
● Controllable Output
● 1kVDC Isolation
● SIP & DIP Package Styles
● UL 94V-0 Package Material
● No Heatsink Required
● Toroidal Magnetics
● Fully Encapsulated
Features