RECOM RP20-242.5SF, RP20-243.3SF, RP20-241.5SF, RP20-241.8SF, RP20-4805SF Datasheet

...
PO 52 www.recom-international.comAugust 2002
Maximum Capacitive Load
RP20-481.5SF: Derating and Efficiency Curves, External Output Trimming
RP20-xx1.5SF 65000µF
RP20-xx1.8SF 65000µF
RP20-xx2.5SF 33000µF
RP20-xx3.3SF 13000µF
RP20-xx05SF 6800µF
POWERLINE - DC/DC-Converter
F-Series, 20W, 1.6 kV Isolation, 2:1 Wide Input Range (Single Output)
20 Watts max. Output Power
International Safety Standard
Design
Six-Sided Continuous Shield
High Efficiency up to 88%
Standard Package,
50.8 mm x 25.4 mm x 10.2 mm
Fixed Switching Frequency
Features
Part Number Input Output Output Input Current Efficiency %
Voltage Voltage Current (see note 5) (see note 6)
RP20-241.5SF 18-36VDC 1.5VDC 6000mA 0.500A 79
RP20-241.8SF 18-36VDC 1.8VDC 6000mA 0.577A 82
RP20-242.5SF 18-36VDC 2.5VDC 6000mA 0.781A 84
RP20-243.3SF 18-36VDC 3.3VDC 5000mA 0.838A 86
RP20-2405SF 18-36VDC 5VDC 4000mA 0.992A 88
RP20-481.5SF 36-75VDC 1.5VDC 6000mA 0.247A 80
RP20-481.8SF 36-75VDC 1.8VDC 6000mA 0.285A 83
RP20-482.5SF 36-75VDC 2.5VDC 6000mA 0.386A 85
RP20-483.3SF 36-75VDC 3.3VDC 5000mA 0.414A 87
RP20-4805SF 36-75VDC 5VDC 4000mA 0.490A 89
Selection Guide 24V and 48V Input Types
125
75
50
25
0
100
Ambient Temperature Range (°C)
-40-25 -10 0 50 60 70 80 90 100
Output Power (%)
Natural Convection
125
75
50
25
0
100
Ambient Temperature Range (°C)
-40-25 -10 0 50 60 70 80 90 100
Output Power (%)
Natural Convection
Derating Curve without Heat-Sink
Derating Curve with Heat-Sink
83
75 74
72
Input Voltage (V)
36
Efficiency (%)
76
77
78
79
80
81
82
73
40 55 60 75
45 50 65 70
82
72 70
60
Output Load (A)
1
Efficiency (%)
74
76
77
78
79
80
81
65
23456
Efficiency vs Input Voltage
Trim
Up
Trim
Down
4
3
5
External Output Trimming
Efficiency vs Output Load
PO 53www.recom-international.com August 2002
Specifications (typical at nominal input and 25°C unless otherwise noted)
Output Power 20W max.
Voltage Accuracy (full Load and nominal Vin) ±1%
Voltage Adjustability ±10%
Minimum Load (see note 1) 10% of FL
Line Regulation (LL-HL at FL) ±0.2% max.
Load Regulation (10% to 100% FL) ±0.5%
Ripple and Noise, 20MHz BW (measured with a 104pF/50V MLCC) 75mVp-p
Temperature Coefficient ±0.02%/°C max. Transient Response Recovery Time, 25% Load Step Change 300µsec
Over Voltage Protection (zener diode clamp): 1.5V Output TBD
1.8V Output TBD
2.5V Output 3.6V
3.3V Output 3.9V
5V Output 6.2V Over Load Protection (% of full load at nominal Vin) 150% typ. Short Circuit Protection Hiccup, Automatic Recovery
Input Voltage Range 24V types nominal input 18-36VDC
48V types nominal input 36-75VDC
Input Filter L-C Type
Input Surge Voltage (100 ms max.) 24V Input 50VDC
48V Input 100VDC
Input Reflected Ripple (see note 2) Nominal Vin and full load 100mAp-p
Start Up Time (nominal Vin and constant resistor load) 20ms typ. Remote ON/OFF (see note 3) DC-DC ON Open or 3.5V < Vr < 12V
DC-DC OFF Short or 0V < Vr < 1.2V Remote off Input Current Nominal Vin 2.5 mA
Isolation Voltage 1600VDC
Isolation Resistance 109Ω
Isolation Capacitance 1000pF
Switching Frequency 300kHz, typ.
Approved to Safety Standards UL 1950, EN60950
Case Material Nickel-Coated Copper
Base Material Non-conducted Black Plastic
Potting Material Epoxy (UL94-V0)
Weight 27g (0.95 oz)
Dimensions 50.8 x 25.4 x 10.2 mm
MTBF (MIL-HDBK-217F, TA = 25°C full load) 3.369 x 105Hours
Operating Temperature Range -40°C to +85°C (with derating)
Maximum Case Temperature +100°C
Storage Temperature Range -55°C to +105°C
Thermal Impedance (see note 4) Natural convection 12°C/Watt
Thermal Shock MIL-STD-810D
Vibration 10-55Hz, 2G, 3 Min. Period, 30 Min. along X, Y and Z