www.recom-international.comAugust 2002PO 56
Specifications (typical at nominal input and 25°C unless otherwise noted)
POWERLINE - DC/DC-Converter
EW-Series, 20W, 1.6 kV Isolation, 4:1 Wide Input Range (Single & Dual Output)
Output Power 20W max.
Voltage Accuracy (full Load and nominal Vin) Single & Dual ±2%
Auxiliary ±5%
Voltage Adjustability ±10%
Minimum Load (see note 1) 10% of FL
Line Regulation (LL-HL at FL) Single & Dual ±0.5%
Auxiliary ±5%
Load Regulation (10% to 100% FL) Single ±0.5%
Dual ±3%
Auxiliary ±5%
Cross Regulation (see note 2) Dual ±5%
Auxiliary ±5%
Ripple and Noise (20MHz BW) Single 75mVp-p
Dual 100mVp-p
Auxiliary 1% of Vout
Temperature Coefficient ±0.02% / °C max.
Transient Response Recovery Time (25% load step change) 500µsec
Over Voltage (zener diode clamp) 3.3V output 3.9V
5V output 6.2V
12V output 15V
15V output 18V
Short Circuit Protection Hiccup,automatic recovery
Input Voltage Range 24V types nominal input 9-36VDC
48V types nominal input 18-75VDC
Input Filter Pi Type
Input Surge Voltage (100 ms max.) 24V input 50VDC
48V input 100VDC
Input Reflected Ripple (see note 3) Nominal Vin and ful load 25mAp-p
Start Up Time (nominal Vin and constant resistor load) 20ms typ.
Remote ON/OFF (see note 4) DC-DC ON Open or 3.5V < Vr < 12V
DC-DC OFF Short or 0V < Vr < 1.2V
Remote Off Input Current 20mA
Efficiency See „Selection Guide“ table
Isolation Voltage 1600VDC
Isolation Resistance 109Ω
Isolation Capacitance 300pF max.
Switching Frequency 300kHz typ.
Approved to Safety Standards UL 1950, EN60950
Case Material Nickel-coated copper
Base Material Non-conducted black plastic
Potting Material Epoxy (UL94-V0)
Weight 48g
Dimensions 50.8 x 40.6 x 10.2 mm
MTBF (see note 5) 1.928 x 106Hours
Operating Temperature Range -40°C to +85°C (with derating)
continued on next page