Input Voltage Range ±10%
Output Voltage Accuracy -2% typ. / ±5% max.
Efficiency (@ Full Load) 65% min. / 70% typ.
Operating Frequency 50kHz min / 65kHz typ. / 105kHz
Output Ripple & Noise 55mVp-p typ. / 100mVp-p max.
Line Voltage Regulation Low Line to High Line @ max. Load 1.2% typ. of 1% Vin
Load Voltage Regulation (10% to 100% Load) 12% typ. / 15% max.
Isolation Voltage (tested for 1 second*) 4kVDC
(rated for 1 minute*) 3kVDC
Isolation Capacitance 75pF max.
Isolation Resistance Viso=500V 1GΩ min.
Short Circuit Protection 1 sec.
Operating Temperature Range -40°C to +85°C
Storage Temperature Range -55°C to 125°C
Humidity 95% max.
Size 19.60mm x 10.20mm x 7.05mm
Weight 2.7g
MTBF (25°C) using MIL-HDBK 217F 850 x 10³ hours
(85°C) using MIL-HDBK 217F 123 x 10³ hours
Certification
UL General Safety Report: E358085-A4 UL60950-1
ECONOLINE
DC/DC-Converter
with 3 year Warranty
RKE-0505S/H
Selection Guide
Part Input Output Output Efficiency Max
Number Voltage Voltage Current Capacitive
SIP 7 (VDC) (VDC) (mA) (%) Load
(1)
RKE-0505S/H 5 5 200 70 1200µf
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
1 Watt
SIP7 Single
Output
● Low Cost 1W Converter
● 4kVDC / 1 sec High Isolation
● Low Output Ripple
●
Wide Operating Temperature Range of
-40°C to +85°C
● Industry Standard Pinout
● UL Certified
Features
Unregulated
Converter
Refer to Application Notes
RoHS
2011/65/EU
6/6
*Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer
to our Application Notes.
UL-60950-1 Certified
E-358085
Derating-Graph
(Ambient Temperature)
Notes
Note1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1second without
damage to the converter.
REV: 1/2015 www.recom-power.comE-60