August 2002EC www.recom-international.com
Selection Guide
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Output Power (Watts)
4.4
3.3
1.1
2.2
100500-25
125
150
Operating Temperature ˚C
Safe Operating Area
0
ECONOLINE - DC/DC-Converter
REC2.2-DRI Series, 2.2 Watt, DIP24, Regulated, Isolated Outputs (Dual Output)
Part Input Output Output Output Efficiency Number Voltage Voltage Voltage Current DIP24 (VDC) (V1VDC) (V2VDC) (mA) (%)
REC2.2-XX05DRI 5, 12, 24 5 5 200/200 56
REC2.2-XX12DRI 5, 12, 24 12 12 90/90 60
REC2.2-XX15DRI 5, 12, 24 15 15 75/75 62
REC2.2-XX24DRI 5, 12, 24 24 24 46/46 62
Input Voltage ±10%
Output Accuracy ±5%
Line Voltage Regulation ±0.5%
Output Power 2.2 Watt max.
Load Voltage Regulation (10% - 100% Full Load) ±0.5%
Ripple and Noise (20MHz limited) 100mVp-p max.
Efficiency at Full Load 50% min.
Isolation Voltage 500VDC min.
Isolation Resistance (Viso = 500VDC) 10 GΩ min.
Isolation Capacitance 100pF min./190pF max.
Short Circuit Protection Short Term
Switching Frequency at Full Load 35kHz min. / 85kHz max.
Operating Temperature -25°C to +70°C (see Graph)
Storage Temperature -55°C to +125°C
Package Weight 12.3g
Features
500VDC Isolation
Dual In-Line Package
Up to 2.2W Regulated Output
Power
100% Burned In
Isolated Outputs
UL94V-0 Package Material
Regulated
August 2002www.recom-international.com EC
ECONOLINE - DC/DC-Converter
REC2.2-DRI Series, 2.2 Watt, DIP24, Regulated, Isolated Outputs (Dual Output)
Package Style and Pinning (mm)
10.29
17.78 typ.
2.0
0.51 typ.
2.54
20.30
REC2.2-0505DRI
RECOM
****
31.50
4.10
15.24
Top View
15 –Vout 2 14 +Vout 2 13
24 23 –Vout 1 22 +Vout 1
+Vin 1
2 3
10 11
–Vin12
2.54
1.00ø+0.15/–0
2.54
XX.X ± 0.5 mm XX.XX ± 0.25 mm
3rd angle projection
Recommended Footprint Details
24 PIN DIP Package