RECOM RACM100-24S Datasheet

Page 1
• Long 5 Year Warranty
• 2MOPP/250VAC
• Suitable for built in Class II Applications
• Wide Input Voltage Range (85-264VAC)
• Low Leakage Current (<75µA)
Regulated Converters
• 5000m Operation
• Active Power Factor Correction
• Connector Set available
Description
The RACM100 is a compact 3.6”x2.44” high efficiency AC/DC power supply with 2xMOPP safety approval for medical applications. These space saving enclosed power supplies have an universal input voltage range (85-264VAC), 4kVAC isolation, require no minimum load and can be used at ambient temperatures of between -25°C and +85°C. The 12V, 15V, 24V or 48V output voltages are fully protected and have tolerances of less than ±0.2% over the entire input voltage range and less than ±0.5% over the entire load range. The RACM100 series is certified to medical safety standard IEC/ES/EN-60601-1 3rd Edition and feature BF rated outputs with less than 75µA leakage current. It has a built-in Class B EMI filter and comes with a five year warranty.
Selection Guide
Part Input Output Output Input Power Efficiency Number Voltage Range Voltage Current @ No Load typ. (VAC) (VDC) (A) (W) (%)
RACM100-12S 85-264 12 8.34 0.3 91
RACM100-15S 85-264 15 6.67 0.3 92
RACM100-24S 85-264 24 4.17 0.3 92
RACM100-48S 85-264 48 2.09 0.3 91
AC/DC Converter
RACM100
E
A
Y
100 Watt Enclosed
5
5
w
a
r
n
r
a
Case Style Single Output
R
y
t
Specifications (measured at T
= 25°C, 250VAC, full load and after warm-up)
A
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage
Input Current
Absolute max. Input Current cold start, 230VAC 60A
Input Frequency Range AC Input 47Hz 63Hz
Start-up Time 1 Second
Rise Time 20ms
Hold up Time 115VAC, full load 16ms
Minimum Load 0%
Power Factor 0.95
Operating Frequency 60kHz
Output Ripple and Noise
(measured @ 20MHz BW)
115VAC, fulll load
230VAC, full load
12VDC, with 10µF/25V MLCC 15VDC, with 10µF/25V MLCC
24VDC, with 1µF/50V MLCC
48VDC, with 0.1µF/100V MLCC
85VAC
120VDC
120mVp-p 150mVp-p 160mVp-p 340mVp-p
264VAC 370VDC
1.15A
0.55A
2MOPP 250VAC
E314885
EN-55011 Certified EN-55022 Certified ES-60601 Certified IEC/EN-60601 Certified
continued on next page
Refer to Applications Notes
REV.: 3/2015www.recom-power.com
MED-1
Page 2
2MOPP
RACM100
AC/DC Converter
Specifications (measured at T
94
92
90
88
Efficiency (%)
86
84
2010 4030 706050 80 90 100
Load vs. Input Voltage Power Factor vs. Load
125
100
80
60
A
Efficiency vs. Load
Load (%)
= 25°C, 250VAC, full load and after warm-up)
230VAC
115VAC
94
92
90
88
Efficiency (%)
86
84
1
Series
Efficiency vs. Input Voltage
100% Load
85
130 150 190 230 25011090 170 240 264
Input Voltage (V)
230VAC
115VAC
50% Load
40
% of Full Load
20
100 115 130 145 160 175 264
85
Input Voltage (V)
Power Factor [ ]
0
4030 6050 8070 90 100
Load (%)
REGULATIONS
Parameter Condition Value
Output Voltage Accuracy 230VAC, full load ±1%
Line Voltage Regulation low line to high line, full load ±0.2%
Load Voltage Regulation
Output Voltage Trim ±10%
Transient Peak Deviation load step from 50% - 75% change at 2.5A/µs 3% Vout max.
Transient Recovery Time load step from 50% - 75% change at 2.5A/µs 500µs typ.
0% to 100% load
10% to 100% load
±0.5% max. ±0.4% max.
PROTECTIONS
Parameter Condition Value
Input Fuse internal line and neutral T3.15A / 250VAC, slow blow type
Short Circuit Protection (SCP) continuous, auto-recovery
Over Load Protection (OLP) % of Iout rated Hiccup Mode, 115% min. / 150% max.
Over Voltage Protection (OVP) % of Vout nominal Latch Mode, 115% min. / 135% max.
I/P to O/P
Isolation Voltage
Means of Protection
Leakage Current 264VAC 75µA max.
Medical Device Classification Type BF applied device
I/P to Chassis
O/P to Chassis
working voltage
4kVAC / 1 minute
1.5kVAC / 1 minute
1.5kVAC / 1 minute
250VAC / continuous
MED-2
continued on next page
REV.: 3/2015 www.recom-power.com
Page 3
Value
RACM100
8mmmin.
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
AC/DC Converter
Specifications (measured at T
Internal Clearance Creepage
Isolation Resistance 500VDC 100MW min.
Insulation Grade Reinforced Insulation
= 25°C, 250VAC, full load and after warm-up)
A
I/P to O/P I/P to O/P
Series
8mm min.
ENVIRONMENTAL
Parameter Condition
Relative Humidity non-condensing 5% to 95% RH
Temperature Coefficient ±0.02% / °C
Operating Temperature Range with derating -25°C to +85°C
Operating Altitude 5000m max.
MTBF (+25°C) according to MIL-HDBK-217F, full load 790.3 x 103 hours
Derating Graph
100
80
60
115VAC
230VAC
40
30
20
Output Current (%)
0
-25 10080
6040200
8555
Ambient Temperature (°C)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
IEC/EN Medical Safety (CB Scheme)
ANSI/AAMI Medical Safety ES60601-1
CAN/CSA Medical Safety C22.2 No. 60601-1
Risk Managment 1408016005 Medical Report + ISO14971 Risk Assessment
1408016004
EMC Compliance Conditions Standard / Criterion
EMI Conducted CISPR 11, EN-55011, Class B
Radiated CISPR 11, EN-55011, Class A
Conducted and Radiated FCC18, Class B
ESD Air ±8kV; Contact ±6kV Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Power Frequency Magnetic Field
Voltage Dip and Interruptions
L-N ±1kV and L-PE/N-PE ±2kV EN61000-4-5, Criteria A
100/230VAC, 50Hz
20V/m
±2kV EN61000-4-4, Criteria A
20Vr.m.s EN61000-4-6, Criteria A
10A/m EN61000-4-8, Criteria A
30% 500ms >95% 10ms >95% 5000ms
EN61000-4-11, EN60601-1-2, Criteria A
EN61000-4-11, EN60601-1-2, Criteria A
EN61000-4-11, EN60601-1-2, Criteria B
IEC/EN-60601-1
continued on next page
REV.: 3/2015www.recom-power.com
MED-3
Page 4
RACM100
AC/DC Converter
Specifications (measured at T
Harmonic Current full load EN61000-3-2; Class D
Voltage Flicker EN61000-3-3, PASS
Thermal Shock MIL-STD-810F
Shock IEC60068-2-27
Vibration IEC60068-2-6
= 25°C, 250VAC, full load and after warm-up)
A
Series
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter Type Value
Case Material Aluminum
Package Dimension (LxWxH) 91.4 x 62.0 x 39.2mm
Package Weight 210g
Dimension Drawing (mm)
Top View
CON1
CON1
76.2
FC 84.2
91.4
Side View
Trim Adj.
22.1
CON2
24.5
39.2
FC 41.3
62.0
AC Input Connector CON1
Pin1 Line Pin3 Neutral
Mates with JST housing: VHR-3N JST crimp terminals: SVH-21T-P1.1
DC Ouptut Connector CON2
Pin1,2 -Vout Pin3,4 +Vout
Mates with JST housing: VHR-4N JST crimp terminals: SVH-21T-P1.1
Tolerance: ±0.5mm FC: fixing center
MED-4
1.20
continued on next page
REV.: 3/2015 www.recom-power.com
Page 5
76.2
FC 41.3
24.5
39.2
1.20
62.0
22.1
FC 84.2
91.4
Trim Adj.
CON1
CON2
CON1
RACM100
AC/DC Converter
Specifications (measured at T
Dimension Drawing (mm)
10.0
= 25°C, 250VAC, full load and after warm-up)
A
Bottom View
14.0
3.5
34.0
Ø4.0
Series
10.4
36.5
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) Cardboard Box 418 x 258 x 105mm
Packaging Quantity 10pcs
Storage Temperature Range -40°C to +85°C
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
REV.: 3/2015www.recom-power.com
MED-5