EU 6 www.recom-international.com
EUROLINE - DC/DC-Converter
RxxN and RxxO Series, 1 Watt, DIP8/SIP4, 1kVDC Isolation (Single Output)
Input Voltage Range VIN(continuous operation) 5V input types 4.5VDC min./ 5.5VDC max.
12V input types 10.8VDC min./ 13.2VDC max.
Reflected Ripple Current (depending on the type) 26 mA p-p min. to 48 mA p-p max.
Voltage Set Point Accuracy See Tolerance Envelope
Line Regulation 1.0% / 1.2% of V
IN
Load Voltage Regulation (10% load to 100% full load) 5V output types 14% min. / 15% max.
9V output types 9% min. / 10% max.
12V output types 7.5% min. / 9.5% max.
15V output types 7% min. / 8.5% max.
Ripple & Noise (20MHz band limited), (depending on the type) 40mVp-p min. / 110mVp-p max.
Isolation Voltage (flash tested for 1 second) 1000VDC min.
Test Voltage (50Hz, 10 seconds) 1000 Vpk min.
Resistance (Viso = 500V) 10 GΩ typ.
Switching Frequency at Full Load V
IN
5V input types 110kHz typ.
V
IN
12V input types 145kHz typ.
Package Weight SIP types 1.30 g
DIP types 1.48 g
Operating Temperature Range (all output types) –40°C min. to +85°C max. (see graph)
Storage Temperature Range –50°C min. +130°C max.
Case Temperature Above Ambient (depending on the type) 5V output types +41°C max.
all other output types +32°C max.
MTTF
1)
(depending on the type) –40°C 302kHrs min. / 2938kHrs max.
+25°C 252kHrs min. / 2414kHrs max.
+85°C 212kHrs min. / 1961kHrs max.
1).
Calculated using MIL-HDBK-217F with nominal input voltage at full load.
Please contact us, if you need exact parameters for the converter you have selected.
Electrical Specifications (measured at T
A
= 25°C, at nominal input voltage and rated output current unless otherwise specified)
Typical Characteristics, Tolerance Envelope and Temperature Derating Graph