www.recom-international.com EU 11
EUROLINE - DC/DC-Converter
RxxA and RxxB Series, 1 Watt, DIP14/SIP7, 1kVDC Isolation (Dual Output)
● Wide Temperature Performance at
full 1 Watt Load, –40°C to +85°C
● Industry Standard Pinout
● 1kVDC Isolation
● Efficiency to 78%
● UL 94V-O Package Material
● Internal SMD Construction
● MTTF up to 2.1 Million Hours
Features
Selection Guide 5V and 12V, input types
Part Number Nom. Input Rated Output Rated Output Input Current Efficiency Isolation Package
Voltage Voltage Voltage Current at Rated Load Capacitance Style
(VDC) (VDC) (mA) (mA) (%) (pF)
R05A05 5 ±5 ±100 289 69 28
R05A09 5 ±9 ±55 270 75 32 DIP14
R05A12 5 ±12 ±42 266 77 34
R05A15 5 ±15 ±33 263 78 36
R05B05 5 ±5 ±100 289 69 28
R05B09 5 ±9 ±55 270 75 32 SIP7
R05B12 5 ±12 ±42 266 77 34
R05B15 5 ±15 ±33 263 78 36
R12A05 12 ±5 ±100 120 69 33
R12A09 12 ±9 ±55 113 74 46 DIP14
R12A12 12 ±12 ±42 111 75 55
R12A15 12 ±15 ±33 110 76 54
R12B05 12 ±5 ±100 120 69 33
R12B09 12 ±9 ±55 113 74 46 SIP7
R12B12 12 ±12 ±42 111 75 55
R12B15 12 ±15 ±33 110 76 54
Absolute Maximum Ratings
Input Voltage VIN5V types 7V
Input Voltage VIN12V types 15V
Short Circuit Duration
1)
1s
Internal Power Dissipation 450mW
Lead Temperature (1.5 mm from case for 10 seconds) 300 °C
1).
Supply voltage must be discontinued at the end of the short circuit duration.