RealWear HMT-1Z1, T1100S Safety Instructions

© 2018 RealWear Inc. All rights reserved. Version 15 20180507
https://www.realwear.com/support support@realwear.com
Power Button
Camera
Lock Ring
Flashlight
Elbow Joint
Display Pod
Mic A1 (A2 on opposite side)
Mic B1
Shoulder Joint
Removable Head Stra
p
Removable Rear Pad
Speaker
Boom Arm
Device Overview
Safety Instructions HMT-1Z1 model T1100S
Display Window
Mic B2
Micro USB
data & charging port located
under cover
Audio Jack
1 Note
This document contains the safety instructions necessary for the safe use of the HMT-1Z1 model T1100S device in explosive and potentially explosive atmospheres. Such areas or zones are referred to as “ex-hazardous areas” in this document.
2 Introduction
This document contains information and safety regulations which are to be observed – without fail ­for safe operation of the device under the described conditions. Non-observance of this information and instructions can have serious consequences and / or may violate regulations. Please read the manual and these safety instructions before using the device. In case of any translation or printing errors, the English version shall apply.
3 Application
3.1 ATEX & IECEx
The HMT-1Z1 model T1100S is approved for use in zone 1, zone 2, zone 21 and zone 22 in accordance with directives 2014/34/EU (ATEX) and the IECEx System.
3.2 NEC & CEC
The HMT-1Z1 model T1100S is approved for use in Division 1 and 2 Class I, II, III.
3.3 Manufacturer
i.safe MOBILE GmbH, i_Park Tauberfranken 10 97922 Lauda-Koenigshofen; Germany
4 Faults and Damage
Before entering ex-hazardous areas, the safety of the device must be checked. If there is any reason to sus­pect that the safety of the device has been compro­mised, it must be withdrawn from use and removed from any ex-hazardous areas immediately.
Measures must be taken to prevent any accidental restarting of the device. The safety of the device may be compromised, if, for example:
• Malfunctions occur.
• The housing of the device shows damage.
• The device has been exposed to excessive loads.
• The device has been stored improperly.
• Markings or labels on the device are illegible.
• Permitted limit values have been exceeded.
It is recommended that a device displaying errors or for which an error is suspected be sent back to an authorized service center to be checked.
5 Ex-relevant / Intrinsic Safety Regulations
Use of this device assumes that the operator ob­serves the conventional safety regulations and has read and understood the user manual, safety instruc-
tions and safety certicate. The following additional
safety regulations must be complied with:
5.1 Charging and battery
• The device may only be charged outside ex-hazardous areas using the i.safe PROTECTOR
1.0 USB-cable (or other equipment approved by i.safe MOBILE GmbH.)
• The device may only be charged at temperatures between +5°C and +40°C.
• The battery is not removable by the user.
5.2 Connections and covers
• Physical connections to other equipment are only permitted outside ex-hazardous areas, using the i.safe PROTECTOR 1.0 USB-cable (or other equipment approved by i.safe MOBILE GmbH.)
• Inside ex-hazardous areas the covers of the Micro USB connector and the Micro SD card slot must be kept closed.
• The audio jack can be used to connect approved headsets inside ex-hazardous areas.
• To ensure the integrity of ingress protection (IP), check that all gaskets are present and functional.
• During charging any headset or accessory must be unplugged from the audio jack.
5.3 Usage environments
• The device may not be taken into zones 0 or 20.
• The device may not be exposed to any aggressive acids or alkalis.
• The device must be protected from impacts with high impact energy, against excessive UV emission and high electrostatic charge processes.
• The permitted ambient operating temperature range is -20°C to +60°C.
5.3 Accessories
• Only accessories approved by i.safe MOBILE GmbH may be used.
• Adjustment of the head strap in ex-hazardous areas is not permitted.
Loading...