WARRANTY INFORMATION
The benefits provided to you under the following warranty are in addition to any other rights and remedies available to you under the law.
1. Warranty
If:
(a) during the first 12 months from the date of purchase (Burner Warranty Period) there is a defect in the Real Flame
gas burner; or
(b) during the first 12 months from the date of purchase (Parts Warranty Period) there is a defect in the gas valves or
other parts of the Real Flame Pit Fire, due to improper workmanship or material, Real Flame will replace or repair the Real Flame Gas Burner without charge. Any replacement product is warranted only for the time remaining on the original Burner Warranty Period or the Parts Warranty Period as relevant.
2. Registration
You must register to receive the benefit of this warranty by completing the warranty registration on our website (www.realflame.com.au) or completing and mailing the attached registration card within 30 days of purchase of your Real Flame Gas Burner (or, if the Real Flame Gas Burner is fitted to a new home, within 30 days of the date of settlement of purchase of such new home).
3. Exclusions
Real Flame is not obliged to replace or repair the Real Flame Gas Burner under clause 1 if:
(a) it has been improperly stored, installed, connected, used, operated or repaired, or damaged, abused, tampered
with, altered (without our written approval), or not maintained in strict accordance with our installation and operating instructions; or
4. Limit of Liability
The warranty provided under this warranty is limited to replacement or repair of the Real Flame Gas Burner only, at our option. To the extent permitted by law, Real Flame excludes liability for consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever, and damage arising from normal wear and tear.
5. Claiming under the Warranty
In order to claim under this warranty you must, within the Burner Warranty Period or the Parts Warranty Period (as relevant), contact Real Flame, providing the original proof of purchase and the details below:
Supplier Name___________________________________________________________________________
Date Of Purchase / settlement of property if new home _________________
Model / Serial Number_______________________
This warranty does not cover the cost of claiming under the warranty or transporting the Real Flame Gas Burner to and from the supplier.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
If you would like to speak to someone about your Real Flame Gas Burner or claiming under this warranty, please contact the Real Flame Service Warranty Desk on 03 8706 2000.
Real Flame Pty Ltd ACN 006 311 155
Head Office: 1340 Ferntree Gully Road, Scoresby 3179
Telephone: 03 8706 2000 Facsimile: 03 8706 2001
INSTALLATION NOTICE
The installation of this appliance is only to be carried out by an authorised person in accordance with the Manufacturers Instructions, local gas fitting regulations, AS/NZS5601.1-2013 installation code for gas burning appliances and any other relevant statutory regulations.
In all cases the installation of this appliance shall meet the requirements as set out in AS/NZS5601.1-2013.
NOTE: A slight smell may be apparent for the first few hours of use. This is due to the heat resistant paint curing. In some instances a slight discolouration may occur inside the firebox. This is a normal condition and is not covered by warranty.
IMPORTANT SAFETY NOTICES
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.
DO NOT USE OR STORE FLAMMABLE MATERIAL NEAR THE APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILST IT IS IN OPERATION.
DO NOT MODIFY THIS APPLIANCE.
THIS APPLIANCE IS DESIGNED TO OPERATE WITH LUMINOUS FLAMES. THIS MAY EXHIBIT SLIGHT CARBON DEPOSITS. THIS IS A NORMAL CONDITION AND IS NOT COVERED BY WARRANTY.
WARNING
This pit fire has a naked flame, care should be taken when it is operating if children or the infirm are in close proximity. A safety screen is recommended if constant supervision is not possible. It is recommended that a secondary guard complying with AS-NZS2286 be installed.
THIS IS PRIMARILY A DECORATIVE APPLIANCE AND IS NOT CERTIFIED AS A SPACE HEATER.
CONTENTS
Contents ..................................................................................................................4
Dataplate ..................................................................................................................5
Dimensions ..............................................................................................................6
Installation instructions ............................................................................................7
Wiring Diagrams.....................................................................................................14
Commissioning procedure ....................................................................................16
Media Installation ...................................................................................................17
Operation - User Instructions.................................................................................20
Troubleshooting .....................................................................................................20
Conversion details .................................................................................................21
Parts List ................................................................................................................22
Real Flame contact information .............................................................................24
DATA PLATE (Affixed to the gas valve controller cover of the appliance.)
OFRD500
Gas Injector Size (mm) TPP N.G.C. (Mj/Hr) Natural Gas 3.30mm 0.90kPa 53 LPG 1.75mm 2.60kPa 44
OFRD700
Gas Injector Size (mm) TPP N.G.C. (Mj/Hr) Natural Gas 4.0mm 0.95kPa 80 LPG 2.40mm 2.60kPa 80
OFRT600x400
Gas Injector Size (mm) TPP N.G.C. (Mj/Hr) Natural Gas 3.30mm 0.90kPa 53 LPG 1.75mm 2.60kPa 44
OFRT800x400
Gas Injector Size (mm) TPP N.G.C. (Mj/Hr) Natural Gas 4.00mm 0.85kPa 75 LPG 2.40mm 2.40kPa 75
OFSQ450
Gas Injector Size (mm) TPP N.G.C. (Mj/Hr) Natural Gas 3.30mm 0.90kPa 53 LPG 1.75mm 2.60kPa 44
OFSQ600
Gas Injector Size (mm) TPP N.G.C. (Mj/Hr) Natural Gas 4.00mm 0.95kPa 80 LPG 2.40mm 2.60kPa 80
DIMENSIONS
MODEL FLANGE DIM FLANGE DIAMETER HEIGHT
OFRD500 560mm 450 OFRD700 760mm 450 OFRT600 X 400 660 460 450 OFRT800 X 400 860 460 450 OFSQ450 510 510 450 OFSQ600 660 660 450
Diameter
Height
Width
Height
Height
Length
Length
Width
61.5
62
24.3
29.8
62.0
30
INSTALLATION INSTRUCTIONS
Select a location where the outdoor fire can be supervised during operation.
The outdoor fire is suitable for outdoor use only and must not be used indoors.
An isolation switch must be fitted at the appliance or on an adjacent wall to allow for emergency shutdown and maintenance.
Installation must meet Australian gas codes AS/NZS5601.1-2013.
Do not install under trees or overhanging branches.
Do not install under eaves, overhang or ceilings.
Ensure adequate space around the fire to enjoy the flame from a safe distance from the heat and flame.
Appliance should be covered or protected in wet weather. Not suitable for use in wet or windy weather.
This appliance shall only be used in an above ground open air situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.
Any enclosure in which the appliance is used shall comply with the following:
An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead cover.
Within a partial enclosure that includes an overhead cover and no more than two walls.
Within a partial enclosure that includes an overhead cover and more than two walls the following shall apply. * at least 25% of the total wall area is completely open, and * at least 30% of the remaining wall area is open and unrestricted
In the case of balconies, at least 20% of the total wall area shall be and remain open and unrestricted.
This appliance shall not be used or installed indoors.
The following figures are diagrammatical representations of outdoor areas.
Above 1500 mm Sides 200 mm
CLEARANCES FROM COMBUSTIBLES - ALL MODELS
Location
Example 1 Example 2