Real Flame LANDSCAPE BALANCED Installation & Operating Manual

LANDSCAPE
®
BALANCED
FLUE SPACE HEATER
INSTALLATION & OPERATING MANUAL
The Landscape 1000 & 1600 are approved to be installed as a zero
clearance firebox and are designed to operate on Natural Gas and
VERSION 26
2
WARRANTY INFORMATION
The benefits provided to you under the following warranty are in addition to any other rights and remedies available to you under the law.
1. Warranty
If:
(a) during the first 15 years from the date of purchase (Firebox Warranty Period), there is a defect in the firebox of the
Real Flame Gas Burner; or
(b) during the first 2 years from the date of purchase (Parts Warranty Period), there is a defect in the gas valves or
other parts of the Real Flame Gas Burner,
due to improper workmanship or material, Real Flame will replace or repair the Real Flame Gas Burner without charge. Any replacement product is warranted only for the time remaining on the original Firebox Warranty Period or the Parts Warranty Period as relevant.
2. Registration
You must register to receive the benefit of this warranty by completing the warranty registration on our website (www.realflame.com.au) or completing and mailing the attached registration card within 30 days of purchase of your Real Flame Gas Burner (or, if the Real Flame Gas Burner is fitted to a new home, within 30 days of the date of settlement of purchase of such new home).
3. Exclusions
Real Flame is not obliged to replace or repair the Real Flame Gas Burner under clause 1 if:
(a) it has been improperly stored, installed, connected, used, operated or repaired, or damaged, abused, tampered
with, altered (without our written approval), or not maintained in strict accordance with our installation and operating instructions; or
(b) it has been installed in an outdoor setting.
4. Limit of Liability
The warranty provided under this warranty is limited to replacement or repair of the Real Flame Gas Burner only, at our option. To the extent permitted by law, Real Flame excludes liability for consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever, and damage arising from normal wear and tear.
5. Claiming under the Warranty
In order to claim under this warranty you must, within the Firebox Warranty Period or the Parts Warranty Period (as relevant), contact Real Flame, providing the original proof of purchase and the details below:
Supplier Name___________________________________________________________________________
Date Of Purchase / settlement of property if new home _________________
Model / Serial Number_______________________
This warranty does not cover the cost of claiming under the warranty or transporting the Real Flame Gas Burner to and from the supplier.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
If you would like to speak to someone about your Real Flame Gas Burner or claiming under this warranty, please contact the Real Flame Service Warranty Desk on 03 8706 2000.
Real Flame Pty Ltd ACN 006 311 155
Head Office: 1340 Ferntree Gully Road, Scoresby 3179
Telephone: 03 8706 2000 Facsimile: 03 8706 2001
WARNING
The “Landscape 1000 & 1600” have a primary safety glass fitted in front of the glass door. This safety glass is fitted to these appliances to reduce the risk of injury from burns and at no time should this glass be permanently removed.
For protection of young children or the infirm, a secondary guard is required.
INSTALLATION NOTICE
The installation of this appliance is only to be carried out by an authorised person in accordance with the Manufacturer’s Instructions, local gas fitting regulations, AS5601-2004 installation code for gas burning appliances and any other relevant statutory regulations.
Do not modify this appliance.
In all cases the installation of this appliance shall meet the requirements as set out in AS5601-2004.
NOTE: A slight smell may be apparent for the first few hours of use. This is due to the heat resistant paint curing. It is recommended to open windows in the room for the first lighting of the fire. In some instances a slight discolouration may occur inside the firebox. This is a normal condition and is not covered by warranty.
IMPORTANT SAFETY NOTICE
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.
DO NOT USE OR STORE FLAMMABLE MATERIAL NEAR THE APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILST IT IS IN OPERATION.
CARE MUST BE TAKEN TO ENSURE THAT ANY RETURN AIR REGISTER OR EXHAUST SYSTEM DOES NOT ADVERSLEY AFFECT THE OPERATION OF THE APPLIANCE OR DRAUGHT OF CHIMNEY OR FLUE.
WARNING
The outer glass panel gets extremely hot! Precaution should be taken and young children supervised at all times when heater is operating.
3
SERVICING
It is recommended you service your gas fire every 2 years as a minimum.
CONTENTS
Contents ..................................................................................................................4
Data Plate.................................................................................................................5
Zero Clearance introduction ....................................................................................6
Dimensions Landscape 1000 ..................................................................................7
Dimensions Landscape 1600 ..................................................................................8
Terminations .............................................................................................................9
Timber frame installation........................................................................................10
Vertical & horizontal venting installation................................................................13
Tests to be carried out by installer .........................................................................14
Pebble set up .........................................................................................................14
Logset set up .........................................................................................................15
Servicing and maintenance ...................................................................................20
Parts list ................................................................................................................22
Gas control assembly ............................................................................................23
Flue termination (cowls) regulations .....................................................................24
Remote control operating guide............................................................................25
Electrical diagram ..................................................................................................28
Troubleshooting .....................................................................................................30
Real Flame contact information .............................................................................32
4
DATA PLATE (Affixed to the base of the unit for reference to gas pressure & consumption)
MODEL LANDSCAPE 1000
GAS TYPE
NATURAL GAS @ 0.6 kPa TEST PRESSURE POINT (HIGH)
INJECTOR SIZE 3 X 2.30mm
GAS CONSUMPTION 41Mj/h
LPG @ 2.60 kPa TEST PRESSURE POINT (HIGH)
INJECTOR SIZE 3 X 1.10mm
GAS CONSUMPTION 41Mj/h
NATURAL GAS @ 0.30 kPa TEST PRESSURE POINT (LOW)
INJECTOR SIZE 3 X 2.30mm
GAS CONSUMPTION 29Mj/h
LPG @ 0.90 kPa TEST PRESSURE POINT (LOW)
INJECTOR SIZE 3 X 1.10mm
GAS CONSUMPTION 29Mj/h
APPROVAL NO: GMK10056
SERIAL NUMBER:
DATE OF MANUFACTURE
MODEL LANDSCAPE 1600
GAS TYPE
NATURAL GAS @ 0.50 kPa TEST PRESSURE POINT (HIGH)
INJECTOR SIZE 4 X 2.75mm
GAS CONSUMPTION 51Mj/h
LPG @ 2.60 kPa TEST PRESSURE POINT (HIGH)
INJECTOR SIZE 4 X 1.00mm
GAS CONSUMPTION 51Mj/h
NATURAL GAS @ 0.26 kPa TEST PRESSURE POINT (LOW)
INJECTOR SIZE 4 X 2.75mm
GAS CONSUMPTION 35Mj/h
LPG @ 1.50 kPa TEST PRESSURE POINT (LOW)
INJECTOR SIZE 4 X 1.00mm
GAS CONSUMPTION 38Mj/h
APPROVAL NO: GMK10056
SERIAL NUMBER:
DATE OF MANUFACTURE
WEIGHT 132 KG
WEIGHT 195 KG
5
LANDSCAPE MODEL
INTRODUCTION
The Real Flame “Landscape” is a ribbon burner space heater for use with Natural Gas Aus & NZ and Propane.
The Real Flame warranty will be voided by, and Real Flame disclaims any responsibility for the following actions:
Modification of the space heater and/or components including balanced flue assembly or glass door.
Use of any component part not manufactured or approved by Real Flame in combination with this “Landscape” fireplace system.
Installation other than as instructed in this manual.
CAUTIONS
Due to its high operating temperature, the appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of the high surface temperature, which could cause burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance.
Clothing or other flammable materials must not be placed on or near the appliance.
SELECTING YOUR APPLIANCE LOCATION
Your appliance may be installed in any location that is free of air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, must be considered when selecting the heater location. Try to select a location that does not interfere with room traffic and offers access for the Balanced Flue terminal installation. Refer to AS5601-2004 for minimum clearances for Balanced Flue termination.
WARNING
When this appliance is installed directly on tile or other combustible materials other than wood flooring, the appliance should be installed on a metal or wood panel extending the full width and depth of the appliance.
6
DIMENSIONS
Landscape 1000
ABCDEF GH
855 467 1000 1160 415 270 150 20
IJKLMN
755 505 65 30 178 190
Landscape 1000 Trim
ABC
1100 467 50
Gas
70mm
90mm
50mm Stand Offs
Powe r
25mm Stand Offs
100mm Stand Offs
Lifting Handles
Tr im
Fixing
channel
for plaster
7
DIMENSIONS
Landscape 1600
ABCDEF
855 467 1600 1760 415 270
GH I J K L MN
150 20 755 700 65 30 178 190
Gas
Powe r
Landscape 1600 Trim
ABC
1700 467 50
Tr im
8
Cowl types
Flue
The Landscape is a balanced flue space heater.
It can be installed with the flue terminating with a horizontal or vertical cowl to suit the application.
LANDSCAPE MODEL (continued)
Vertical top termination
Vertical top termination
90° Bend
45° Bend
300mm 600mm 1200mm
RF/HZ
Horizontal rear termination
Model Inner Outer
1000 100 180
1600 150 225
AB
265 370
315 315
90° Bend
AB
260 200
270 270
45° Bend
Flue Components
A A
B
B
9
LANDSCAPE MODEL (continued)
Timber Frame Installation Procedure
Step 1
Construct the base for the unit. Ensure base is adequate for the weight of the fire.
Step 2
Call for delivery of the unit, position on the base and fit off gather, flues and termination. Connect gas and power.
FLUE
GATHER
GAS
POWER
Termination outside
(Horizontal shown)
C
Vertical Termination
Base of unit to
centre of flue
1000 = 1695 1600 = 1637
Back of unit to
centre of flue
(Excluding 25mm
standoff)
1000 = 160 1600 = 122