The Heatseeker Gas Firebox is approved to be installed into a masonary
fireplace and as a zero clearance firebox and is designed to operate on
Natural Gas and Propane (LPG) gases ONLY. Approval Number GMK10100.
Installed primarily as a decorative appliance. Not certified as a Space Heater.
VERSION 35
®
WARRANTY INFORMATION
The benefits provided to you under the following warranty are in addition to any other rights and remedies available to
you under the law.
1. Warranty
If:
(a)during the first 15 years from the date of purchase (Firebox Warranty Period), there is a defect in the firebox of the
Gas Burner; or
(b)during the first 2 years from the date of purchase (Parts Warranty Period), there is a defect in the gas valves or
other parts of the Gas Burner,
due to improper workmanship or material, Glen Dimplex will replace or repair the Gas Burner without charge. Any
replacement product is warranted only for the time remaining on the original Firebox Warranty Period or the Parts
Warranty Period as relevant.
2. Registration
You must register to receive the benefit of this warranty by completing the warranty registration on our website
(www.realflame.com.au) or completing and mailing the attached registration card within 30 days of purchase of
your Gas Burner (or, if the Gas Burner is fitted to a new home, within 30 days of the date of settlement of purchase
of such new home).
3. Exclusions
Glen Dimplex is not obliged to replace or repair the Gas Burner under clause 1 if:
(a)it has been improperly stored, installed, connected, used, operated or repaired, or damaged, abused, tampered
with, altered (without our written approval), or not maintained in strict accordance with our installation and
operating instructions; or
(b)it has been installed in an outdoor setting.
4. Limit of Liability
The warranty provided under this warranty is limited to replacement or repair of the Gas Burner only, at our option.
To the extent permitted by law, Glen Dimplex excludes liability for consequential loss or any other loss or damage
caused to property or persons arising from any cause whatsoever, and damage arising from normal wear and tear.
5. Claiming under the Warranty
In order to claim under this warranty you must, within the Firebox Warranty Period or the Parts Warranty Period
(as relevant), contact Glen Dimplex, providing the original proof of purchase and the details below:
Date Of Purchase / settlement of property if new home _________________
Model / Serial Number_______________________
This warranty does not cover the cost of claiming under the warranty or transporting the Real Flame Gas Burner to and
from the supplier.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a
replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.
You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
If you would like to speak to someone about your Gas Burner or claiming under this warranty, please contact the
Service Warranty Desk on 1300 554 155.
Glen Dimplex Australia Pty Ltd ACN 69 118 275 460
Head Office: 1340 Ferntree Gully Road, Scoresby 3179
he installation of this appliance is only to be carried out by an authorised person in accordance
T
with the Manufacturer’s Instructions, local gas fitting regulations, AS/NZS5601.1-2013 installation
code for gas burning appliances and any other relevant statutory regulations.
In all cases the installation of this appliance shall meet the requirements as set out in
AS/NZS5601.1-2013.
NOTE: A slight smell may be apparent for the first few hours of use. This is due to the heat resistant
paint curing. It is recommended to open windows in the room for the first lighting of the fire. In some
instances a slight discolouration may occur inside the firebox. This is a normal condition and is not
covered by warranty.
IMPORTANT SAFETY NOTICES
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.
DO NOT USE OR STORE FLAMMABLE MATERIAL NEAR THE APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILST IT IS IN OPERATION.
CARE MUST BE TAKEN TO ENSURE THAT ANY RETURN AIR REGISTER OR EXHAUST SYSTEM
DOES NOT ADVERSLEY AFFECT THE OPERATION OF THE APPLIANCE OR DRAUGHT OF
CHIMNEY OR FLUE.
DO NOT MODIFY THIS APPLIANCE.
THIS APPLIANCE IS DESIGNED TO OPERATE WITH LUMINOUS FLAMES. THIS MAY EXHIBIT
SLIGHT CARBON DEPOSITS.
WARNING
This firebox has a naked flame, care should be taken when it is operating if children or the infirm are in
close proximity. A safety screen is recommended if constant supervision is not possible. It is recommended
that a secondary guard complying with AS-NZS2286 be installed. The appliance is not intended for use by
persons (including children) with reduced physical, sensory or mental capabilitites, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they do not play with the
appliance.
SERVICING
It is recommended you service your gas fire every 2 years as a minimum.
VENTILATION REQUIREMENTS
MODELEFFECTIVE VENTILATION
60018,000 sq mm
85032,000 sq mm
100032,000 sq mm
THIS IS PRIMARILY A DECORATIVE APPLIANCE AND IS NOT CERTIFIED AS A SPACE HEATER.
Real Flame contact information ............................................................................52
4
DATA PLATE (Affixed to burner)
HSIB600
itted with Magiglo 400 or 400EI burner
F
asInjector Size (mm)TPPN.G.C. (Mj/Hr)
G
Natural Gas1 x 2.600.80 kPa28
ULPG1 x 1.302.70 kPa21
Fitted with Magiglo 540 or 540EI burner
GasInjector Size (mm)TPPN.G.C. (Mj/Hr)
Natural Gas2 x 2.250.80 kPa37
ULPG2 x 1.102.60 kPa33
HSIB850
Fitted with Magiglo 540 or 540EI burner
GasInjector Size (mm)TPPN.G.C. (Mj/Hr)
Natural Gas2 x 2.250.80 kPa37
ULPG2 x 1.102.60 kPa33
Fitted with Magiglo 750 or 750EI burner
GasInjector Size (mm)TPPN.G.C. (Mj/Hr)
Natural Gas3 x 1.900.75 kPa39
ULPG3 x 0.952.55 kPa34
HSIB1000
Fitted with Magiglo 750 or 750EI burner
GasInjector Size (mm)TPPN.G.C. (Mj/Hr)
Natural Gas3 x 1.900.75 kPa39
ULPG3 x 0.952.55 kPa34
5
PARTS
Rear Log Fixing Hole
urner Port
B
Pilot
ssembly
Detachable Skirt
Burner Pressure Test Point
Maximum Pressure Setting Screw
inimum Pressure Setting
M
Pilot Pressure Adjustment
A
Pilot Cover Plate
as Connection
G
ixing
F
Bracket
TO CHECK PRESSURES
1. Fit manometer to test point.
2. Adjust pilot pressure screw (wind screw fully in, then wind out 2 1/2 full turns).
3. Adjust maximum burner pressure screw (wind max pressure screw out 2 full turns).
4. Ignite burner and set to maximum rate.
5. Adjust regulator pressure until burner pressure is correct.
6. Adjust maximum burner pressure - screw in adjustment screw to data plate setting.
7. Turn valve to low setting. Adjust valve minimum pressure.
8. Complete tests for safety/leakage and connections.
9. Turn burner off.
10. Replace regulator cap.
11. Remove manometer, replace sealing screw and washer and refit valve cover.
6
HEATSEEKER INBUILT MODEL
OFFOOFOFF
P
P
IPI
L
P
I
L
O
P
I
L
O
T
P
I
L
O
T
•Unit installed into an existing “working” fireplace requires an AGA approved 225mm gas
owl and chimney plate fixed to the chimney top.
c
•If the fireplace is not a “working” fireplace, then the applicable flue to the model being
installed should be installed using a gather, single skin flue and AGA approved gas cowl.
•If the flue is to be exposed, or enclosed with any combustible material, the appropriate
approved twin skin flue and gas cowl is required.
•For Type 1 installations models with an ODS pilot must be used.