Ready Access AA300 Service Manual

AA300
Access Air 300
Heated Air Curtain System
TABLE OF CONTENT
Topic
Disclaimer 3 Serial Number Identification 3 Contact Sheet 3 Introduction 4 Product Information Description 4 Specifications 5 Dimensions 5 Safety Information 5 Installation Procedures Physical Installation 6 Electrical Installation 7 Operations Control Identification and Operations 8 Modes of Operation 8 Maintenance Maintenance Schedule Daily 9 Monthly 9 Yearly 9 Service Troubleshooting Guide (Cause and Effect) 10 Parts Lists Complete Parts List (Description/Part Number) 11 Drawings - Exploded Views / Schematics 12 Appendix “A” – Heater Assembly Replacement 14
Page
DISCLAIMER
Ready Access Disclaims any Liability for any damage or harm caused to the AA300 Air Curtain, It’s Operator or any other equipment however caused if the AA300 Air Curtain is repaired or serviced by anyone other than an authorized service engineer or Contrary to the manufacturers written instruction contained herein.
This manual is intended for use by the in-house or authorized field service engineers and sales representatives
The manufacturer maintains the right to update, add or issue a new service manual at any time without notice, thereby rendering all previous issues obsolete.
Please write the Serial Number and Installation Date for your drive-thru window in the spaces provided.
SERIAL NUMBER
Date of Installation
Ready Access 1815 Arthur Drive West Chicago, Illinois 60185 Email: ready@ready-access.com
CONTACT INFORMATION
For sales and service contact
Tel: 630-876-7766 Tel: 800-621-5045
Fax: 630-876-7767
Website: www.ready-access.com
INTRODUCTION
The Ready Access AA300 Pass-Thru Air Curtain System is designed to be an integral part of your drive-thru operation by providing comfort for both operator and customer during the coldest of days as well as satisfying health department codes for fly fan application.
PRODUCT INFORMATION
Modes of Operation The Ready Access AA300 Pass-thru Air Curtain System is versatile in function and design, offering operators four separate modes of operation. * Outside warm air flow only * Inside warm air flow only * Both outside and inside warm airflow * Outside fly fan operation only
Features and Benefits Satisfies heath department requirements for "Fly Fan" applications while it reduces and deflects the amount of outside wind blowing into the building. This also reduces heating and air­conditioning loss as well as reducing unwanted environment factors such as dust and exhaust fumes from entering the building. Acts as a fly fan to deter insects from entering the building during warm weather conditions. Provides the owner/operator with a stable, comfortable working environment for all crewmembers. Reduces Drive-Thru operation expenses by diminishing employee turnover.
Unique Design The AA300 Air Curtain System is the only system on the market today that offers an outside and inside heated airflow. It is designed for use with any flush mount window.
Quality Construction The exterior housing of the AA300 Air Curtain System is manufactured using bronze or clear anodized aluminum.
Fully Assembled, Ready to Install The Access Air 300 system is shipped completely pre-assembled and ready for installation, lowering installation costs. Normal installation for new store construction takes less than two hours.
Three to Five Day Shipping Ready Access will ship any standard Access Air 300 System in 3 to 5 days from receipt of order.
Warranty and Service Support Your Access Air 300 System comes with a one year limited warranty on parts and labor. In addition, each Pass-Thru Air Curtain System is backed by a nationwide service organization.
AVAILABLE OPTIONS Power coat painting is available upon request for a wide range of custom colors.
Number
USA International
AA300 208/240
VAC
60Hz Single Phase
SPECIFICATIONS AND PERFORMANCE
Unit Voltage Model
220/240
VAC
50/60 Hz
Single Phase
Heater
Watts
7100
W
Actual
Unit
Amps
32 A
Air
Velocity
WINTER
600FPM-
SUMMER
800 FPM
at
Nozzle
Dimensions
In Inches
W x H x D
See Below
Weight
In
Shipping
Carton
85 lbs
Dimensions
Figure 1
SAFETY INFORMATION
WARNING: To avoid the risk of fire, Electric Shock or injury to persons, observe the following:
Before servicing or cleaning the unit, switch the power off at the mechanical switch near the unit (Installed by an Electrician) or the electrical entry service panel/circuit breaker. (Load Center) OSHA LOCK OUT – TAG OUT procedures are to be observed to prevent power from being switched on accidentally.
Any Installation and / or Electrical work must be done by QUALIFIED persons in accordance with all applicable codes / standards and manufacturers recommendations and specifications.
DO NOT insert fingers and / or foreign objects into the Air Curtain. DO NOT block or tamper with the unit in any manner while it is in operation.
This product must not be used in Potentially Dangerous locations such as Flammable, Explosive Chemical – laden environment.
DO NOT attach duct work to this product or attempt to use it as a make-up air heater. Such use voids the warranty and may create unsafe conditions.