AA300
Access Air 300
Heated Air Curtain System
TABLE OF CONTENT
Topic
Disclaimer 3
Serial Number Identification 3
Contact Sheet 3
Introduction 4
Product Information
Description 4
Specifications 5
Dimensions 5
Safety Information 5
Installation Procedures
Physical Installation 6
Electrical Installation 7
Operations
Control Identification and Operations 8
Modes of Operation 8
Maintenance
Maintenance Schedule
Daily 9
Monthly 9
Yearly 9
Service
Troubleshooting Guide (Cause and Effect) 10
Parts Lists
Complete Parts List (Description/Part Number) 11
Drawings - Exploded Views / Schematics 12
Appendix “A” – Heater Assembly Replacement 14
Page
2
DISCLAIMER
Ready Access Disclaims any Liability for any damage or harm caused to the AA300 Air Curtain,
It’s Operator or any other equipment however caused if the AA300 Air Curtain is repaired or
serviced by anyone other than an authorized service engineer or Contrary to the manufacturers
written instruction contained herein.
This manual is intended for use by the in-house or authorized field service engineers and sales
representatives
The manufacturer maintains the right to update, add or issue a new service manual at any time
without notice, thereby rendering all previous issues obsolete.
Please write the Serial Number and Installation Date for your drive-thru window in the spaces
provided.
SERIAL NUMBER
Date of Installation
Ready Access
1815 Arthur Drive
West Chicago, Illinois 60185
Email: ready@ready-access.com
CONTACT INFORMATION
For sales and service contact
Tel: 630-876-7766
Tel: 800-621-5045
Fax: 630-876-7767
Website: www.ready-access.com
3
INTRODUCTION
The Ready Access AA300 Pass-Thru Air Curtain System is designed to be an integral part of
your drive-thru operation by providing comfort for both operator and customer during the coldest
of days as well as satisfying health department codes for fly fan application.
PRODUCT INFORMATION
Modes of Operation
The Ready Access AA300 Pass-thru Air Curtain System is versatile in function and design,
offering operators four separate modes of operation.
* Outside warm air flow only
* Inside warm air flow only
* Both outside and inside warm airflow
* Outside fly fan operation only
Features and Benefits
Satisfies heath department requirements for "Fly Fan" applications while it reduces and deflects
the amount of outside wind blowing into the building. This also reduces heating and airconditioning loss as well as reducing unwanted environment factors such as dust and exhaust
fumes from entering the building. Acts as a fly fan to deter insects from entering the building
during warm weather conditions.
Provides the owner/operator with a stable, comfortable working environment for all
crewmembers. Reduces Drive-Thru operation expenses by diminishing employee turnover.
Unique Design
The AA300 Air Curtain System is the only system on the market today that offers an outside and
inside heated airflow. It is designed for use with any flush mount window.
Quality Construction
The exterior housing of the AA300 Air Curtain System is manufactured using bronze or clear
anodized aluminum.
Fully Assembled, Ready to Install
The Access Air 300 system is shipped completely pre-assembled and ready for installation,
lowering installation costs. Normal installation for new store construction takes less than two
hours.
Three to Five Day Shipping
Ready Access will ship any standard Access Air 300 System in 3 to 5 days from receipt of
order.
Warranty and Service Support
Your Access Air 300 System comes with a one year limited warranty on parts and labor. In
addition, each Pass-Thru Air Curtain System is backed by a nationwide service organization.
AVAILABLE OPTIONS
Power coat painting is available upon request for a wide range of custom colors.
4
Number
USA International
AA300 208/240
VAC
60Hz
Single
Phase
SPECIFICATIONS AND PERFORMANCE
Unit Voltage Model
220/240
VAC
50/60 Hz
Single
Phase
Heater
Watts
7100
W
Actual
Unit
Amps
32 A
Air
Velocity
WINTER
600FPM-
SUMMER
800 FPM
at
Nozzle
Dimensions
In Inches
W x H x D
See Below
Weight
In
Shipping
Carton
85 lbs
Dimensions
Figure 1
SAFETY INFORMATION
WARNING: To avoid the risk of fire, Electric Shock or injury to persons, observe the following:
Before servicing or cleaning the unit, switch the power off at the mechanical switch near the unit
(Installed by an Electrician) or the electrical entry service panel/circuit breaker. (Load Center)
OSHA LOCK OUT – TAG OUT procedures are to be observed to prevent power from being
switched on accidentally.
Any Installation and / or Electrical work must be done by QUALIFIED persons in accordance
with all applicable codes / standards and manufacturers recommendations and specifications.
DO NOT insert fingers and / or foreign objects into the Air Curtain.
DO NOT block or tamper with the unit in any manner while it is in operation.
This product must not be used in Potentially Dangerous locations such as Flammable,
Explosive Chemical – laden environment.
DO NOT attach duct work to this product or attempt to use it as a make-up air heater.
Such use voids the warranty and may create unsafe conditions.
5