STICK-ON® SERIES
Model ST-MPA48
Dual Microphone Phantom Adapter
Phantom Adapter for Two Mics
48 Vdc Fixed Phantom Voltage
P48 per IEC 61938
Operates From External 12 V Battery or
24 V Power Supply
Phantom Conversion with Full Frequency
Response
The ST-MPA48 is part of a group of products in the STICK-ON series from Radio Design Labs. The durable bottom adhesive permits quick,
permanent or removable mounting nearly anywhere or it may be used with RDL’s STR-19A or STR-19B racking adapters for rack mounting! The
ST-MPA48 allows any existing microphone input to be converted to a phantom mic input for use with any condenser microphone, with a big plus,
you can put it where you need it! STICK-ONs are designed, built and rated for continuous duty in professional A/V systems.
APPLICATION: The ST-MPA48 contains two identical phantom power circuits and a common
power supply input. If only one mic input is to be converted for phantom operation, only one
circuit needs to be used. Each circuit has a mic input and a mic output. Phantom voltage appears
on each of the mic input terminals. Therefore, the ST-MPA48 can convert any existing mic input
into a 48 Vdc phantom powered input. Phantom voltage is not present on the output terminals.
The power supply input terminals may be fed with any dc voltage from 10.5 volts to 26 volts.
RDL 659 6th St. Prescott, AZ., USA 86301 (928) 443-9391 FAX (928) 443-9392 www.rdlnet.com
![](/html/43/4306/4306e1679717a8b59aa7d596a3a838785212054b377ad8a68308ecc19678ca87/bg2.png)
STICK-ON® SERIES
Model ST-MPA48
Dual Microphone Phantom Adapter
Installation/Operation
Declaration of Conformity available from rdlnet.com.
Sole EMC specifications provided on product package.
Specifications are subject to change without notice.
TYPICAL PERFORMANCE
Channels: 2
Frequency Response: 20 Hz to 100 kHz (± 0.025 dB, 150 Ω source, 1 kΩ load)
Phantom Voltage: P48, 48 Vdc
Standard for Phantom: IEC 61938: 2013
Input Voltage Range: 10.5 Vdc to 26 Vdc (for 48 Vdc output)
Ambient Operating Environment: 0° C to 55° C
Power Requirement: GROUND-REFERENCED,
12 Vdc @ 150 mA (with 20 mA load)
24 Vdc @ 80 mA (with 20 mA load)
Radio Design Labs Technical Support Centers
U.S.A. (800) 933-1780, (928) 778-3554; Fax: (928) 778-3506
891-1165A