RDL SAS-8C Datasheet

SourceFlex™ System
Model SAS-8C 8 Station Controller
Installation/Operation
EN55103-1 E1-E5; EN55103-2 E1-E4
Typical Performance reflects product at publication time exclusive of EMC data, if any, supplied with product. Specifications are subject to change without notice.
SAS-8C
1] Set SAS-8C GAIN controls fully CCW and connect power to SAS-8C. 2] Connect ribbon cable from prior SourceFlex product, (SAS-8i or other SAS-8C. 3] Wire REMOTE STATION "1" terminals 1 through 6 directly to terminals 1 through 6 of SourceFlex remote listening station. Repeat for output channels 2 through 8. 4] Verify PWR LED is illuminated for each output. If LED is not illuminated, there is a wiring short. 5] Connect remote listening stations and run the remote station gain to maximum. 6] Set each GAIN pot on each SAS-8C output for the maximum desired listening level at the respective listening station.
TYPICAL PERFORMANCE
Input, bus: 24-pin ribbon cable header driven from SAS-8i (or other SAS-8C loop-thru jack, input cable included) Output, bus: 24-pin ribbon cable header loop-thru output to drive additional SAS-8C Outputs (8): 6-position removable terminal blocks (connection to remote Listening Station) Audio Output Gain Range: 40 dB (trimpot presettable) Indicators: LED – output voltage present at Remote Outputs Power Requirement: 24 Vdc @ 2 A, Ground-referenced
INTERCONNECT
(TOP VIEW)
IN
OUT
Connect Interconnect cable from previous SAS-82 or SAS-88
or SAS-8C
Each SAS-8C comes supplied with an Interconnect Cable
Connect Interconnect Cable to next SAS-82 or SAS-8C (if present)
PWR
1
GAIN
24 Vdc 2 AMPS POWER
OR
24 Vdc
2 AMPS
12 4356
Connect to SourceFlex listening stations, such as SAS-SM8, SAS-HC8, SAS-RC 8, D SERIES-SFRC8 or D SERIES-SFRC8L with wiring as shown
REMOTE STATION 2REMOTE STATION 1
32 456 312 546
GAIN
13246
GAIN
SAS-8C
Connect Interconnect cable from previous SAS-82 or SAS-88 or SAS-8C
Each SAS-8C comes supplied with an Interconne ct Cable
OUT
5
IN
132 546
GAIN
INTERCONNECT
GAIN
(TOP VIEW)
Connect Interconnect Cable to next SAS-82 or SAS-8C (if present)
REMOTE STATION 5REMOTE STATION 4REMOTE STATION 3
1 5324
REMOTE STATION 6
6
132546 21354
GAIN
DETAIL
24V
DC
PWR
24 Vdc 2 AMPS POWER
OR
24 Vdc
2 AMPS
Gain Adjustment
for Channel #1
Output
LED is on when power is fed to
remote listening
station
REMOTE STATION 8REMOTE STATION 7
GAIN
REMOTE STATION 1
1 345
GAIN
Connect to SourceFlex listening stations, such as SAS-HC8, D SERIES -SFRC8 or D SERIES-SFRC8L with wiring as shown
Connect as Shown when using CAT5 or Equivalent Four Pair UTP Cable
6213546
GAIN
2
21 534 6
white/blue blue/white
white/orange orange/white
white/green green/white
white/brown brown/white
6 21
GAIN
1
2
3
4
5
6
891-9120A
Radio Design Labs Technical Support Centers
U.S.A. (800) 933-1780, (928) 778-3554; Fax: (928) 778-3506
Europe [NH Amsterdam] (++31) 20-6238 983; Fax: (++31) 20-6225-287