RDL FP-DCC1 Data Sheet

Model FP-DCC1 DC to DC Converter
ANYWHERE YOU NEED...
Mobile Powering of 24 Vdc Modules
24 Vdc Ground-referenced Power
Separate High Current and Low Noise
Outputs
Terminal Block and dc Jack Outputs
Ultra-Compact All Metal Construction
Convenience of RDL FLAT-PAKs
You Need The FP-DCC1!
The FP-DCC1 is part of the group of versatile FLAT-PAK products from Radio Design Labs. The unique FLAT-PAK case can be directly screwed or bolted to cabinets or shelves. Optionally available rack­mounting accessories permit single or multiple FLAT-PAK module mounting. All FLAT-PAK modules are supplied with a power interconnect cable for daisy chaining multiple modules from a single power supply.
APPLICATION: The FP-DCC1 is the ideal choice in many applications where audio or video modules need to be powered from a 12 Vdc source. Ground-referenced RDL modules may be operated from one of the FP-DCC1s two outputs. One is a high current output providing 400 mA @ 24 Vdc intended to power multiple modules (see RDL ST-PD5 Power Supply Distributor for multiple module installations) or RDL audio power amplifiers (such as ST-PA2 or ST-PA6). A second low noise output is heavily filtered and provides 50 mA @ 24 Vdc specifically to power microphone level high gain modules, such as microphone preamplifiers. Both outputs may be used simultaneously. When the FP-DCC1 is used to power one or more Flat-Pak series modules, the high current (400 mA) output is connected through the dc power jack located on the connection end panel. Other ground-referenced modules are powered by connecting to the plug-in terminal block on the FP-DCC1. Input power connections are also made using either the plug-in barrier block terminals.
The FP-DCC1 outputs are regulated to provide 24 Vdc for input voltages normally encountered in 12 Vdc battery circuits. If voltage in excess of 15 Vdc (possible if a vehicle’s regulator should fail) is connected to the FP-DCC1 input, the module protects itself by shutting down its internal circuitry and illuminating the OVERVOLTAGE LED. The FP-DCC1 input and outputs are protected against excessive currents and reverse voltages. Two fuses are provided. These fuses are the standard miniature automotive plug-in blade style. The FP-DCC1 is not intended to power floating (bipolar) modules. Adequate ventilation is recommended.
The FP-DCC1’s low profile and compact size permit mounting in confined spaces and in various locations. The removable input/output connectors permit pre-wiring and subsequent module installation in tight spaces. Wherever regulated, ground-referenced 24 Vdc power from a 12 Vdc source is needed to provide reliable compact power, the FP-DCC1 is the ideal choice. Combine it with other RDL products as part of a complete mobile audio/video system.
RDL 659 N. 6th St. Prescott, AZ., USA 86301 (928) 443-9391 FAX (928) 443-9392 www.rdlnet.com
Model FP-DCC1 DC to DC Converter
Use Only with Ground-Referenced Modules
INPUT 12 VDC 2 AMPERES
INPUT
OVERVOLTAGE
CONNECT ' OUTPUT A ' LOAD TO BLOCK OR DC JACK
OUTPUT B 24 VDC 50mA
OUTPUT A 24 VDC 400mA
Installation/Operation
EN55103-1 E1-E5; EN55103-2 E1-E4
Output for low noise high gain modules.
OUT
IN
IN
INBA
WIRING
2
1
FUSES
BA
1A
2A
OUT
400mA
24 VDC
Typical Performance reflects product at publication time exclusive of EMC data, if any, supplied with product. Specifications are subject to change without notice.
12V
G A I N
BASS EQ INPUTS
Power to Additional
Flat-Pak Modules, Total
Current Not to Exceed 400 mA
PROFESSIONAL ADJUSTABLE MICROPHONE PREAMPLIFIERS
INPUT
PHNTM A
A B
OUTPUTS
AUDIO POWER AMPLIFIER
6 WATTS RMS 8 OHMS
POWER
B PWR
P O W E R
GAINOUTPUT
TYPICAL PERFORMANCE Outputs (3): One 24 Vdc regulated @ 400 mA (plug-in terminal block) One 24 Vdc regulated @ 400 mA (dc power jack) (Note: The combined load for both the above outputs is 400 mA) One 24 Vdc regulated @ 50 mA filtered (plug-in terminal block) Fuses (2): One 2 A Automotive blade style miniature fuse (Input) One 1 A Automotive blade style miniature fuse (Output) Power Requirement: 11 to 14 Vdc @ 1 A, Ground-referenced (plug-in terminal block) Overall Dimensions: Height: 1.25 in. 3.18 cm Width: 3.25 in. 8.26 cm Length: 6.54 in. 16.61 cm
891-2000C
Radio Design Labs Technical Support Centers
U.S.A. (800) 933-1780, (928) 778-3554; Fax: (928) 778-3506
Europe [NH Amsterdam] (++31) 20-6238 983; Fax: (++31) 20-6225-287
Loading...