RDL D-BZR Datasheet

ACCESSORIES
Models D-BZR
Audio Alert Module
Audible Alert of A Remote Condition An LED Alarm Indicator A Front-Panel Reset Button Remote Reset Provision Momentary or Latching Operation Selectable Audio Level
The D-BZR is an audible alert module. The D-BZR may be mounted in a wall-box enclosure for use in walls or cabinets.
APPLICATION: The D-BZR is the ideal choice in installations requiring an audible alert.
Rear-panel terminals permit connection of a trip signal, a remote reset button, external power supply, and a jumper to set the audible alert level. The D-BZR is activated when the TRIP input is momentarily connected to ground. The BZR then sounds the alert and remains in the alert mode until reset by either the front-panel RESET button, or by a remote reset button. Normally, the D-BZR latches in the alert mode. Alternately, the D-BZR may be configured to sound the alert only while the TRIP terminal is grounded. This may be accomplished by installing a jumper from the remote RESET to ground. For use in confined areas, the standard alert may be too loud. The level may be reduced by removing a jumper provided on the rear-panel terminal block.
A front-panel LED lights when the module is in the alert mode. If several D-BZRs are installed at a common location, this visual indication shows the operator which unit is tripped.
The D-BZR power supply input accepts 24 Volts ac or dc. The D-BZR is a negative ground-referenced product. In the unlikely event it is connected on a common 24 Vac supply together with equipment which is positive ground-referenced and not transformer isolated, a ground fault may occur. The D-BZR automatically detects such a fault and disconnects itself from the power input.
D-BZR
RDL 659 6th St. Prescott, AZ., USA 86301 (928) 443-9391 FAX (928) 443-9392 www.rdlnet.com
ACCESSORIES
Model D-BZR
Audio Alert Module
RELAY OR SWITCH
TO RESET ALARM
RELAY OR SWITCH
TO TRIP ALARM
24 VDC/VAC
POWER
SOURCE
RESET
TRIP
GND
LOUD
24V DC
OR
24V AC
GROUND RESET TERMINAL
FOR MOMENTARY ALARM
RELAY OR SWITCH
TO TRIP ALARM
MOMENTARY OPERATIONLATCHING OPERATION
24 VDC/VAC
POWER
SOURCE
Installation/Operation
EN55103-1 E1-E5; EN55103-2 E1-E4
Typical Performance reflects product at publication time exclusive of EMC data, if any, supplied with product. Specifications are subject to change without notice.
REMOVE JUMPER ON
"LOUD" TERMINALS TO
LOWER ALARM VOLUME
IF A JUMPER IS PLACED
BETWEEN THE RESET
TERMINAL AND GROUND
TERMINAL THEN THE
ALARM WILL ONLY SOUND
WHILE THE TRIP TERMINAL
IS GROUNDED
RESET
TRIP
GND
LOUD
24V DC
OR
24V AC
REAR
LED INDICATES THAT
ALARM IS TRIPPED
PUSH RESET BUTTON
TO RESET ALARM
FRONT
TYPICAL PERFORMANCE
Control Inputs: TRIP and RESET (ground to activate) Audible Alert: Approx. 4 kHz 85 dBspl @ 10cm (loud), or 75 dBspl @ 10cm (soft) Power Requirement: 24 Vdc or ac @ 10 mA, Ground-referenced D-BZR Dimensions: Height: 4.1 in. 10.4 cm Depth: 1.6 in. 4.1 cm Width: 1.3 in. 3.3 cm