Rcom REPTILE PRO 90 User Manual

WATER
DIGITAL REPTILE INCUBATOR
REPTILE PRO 90
USER'S MANUAL
Love of life begins with "Rcom"
Ver. 4
North America Sales & Service www.RcomCo.com
6. How to Clean
(1) Disassembling and Cleaning the Incubator
18 ~ 19
1. Introduction
(1) Rcom Reptile 90 Introduction
3 ~ 7
(2) Safety precautions
(4) Name & Function of Operation Parts
(3) Identification of Parts and Composition
8. Product Information
(1) Troubleshooting
21 ~ 23
(2) Specification
4. Function Settings
(1) Incubation Modes / Incubation start with Automatic Mode
11 ~ 17
(2) Incubation start with Manual Mode
(3) Incubation start for Other Reptiles
(5) Incubation conditions reset / How to Set Turn ON, OFF Humidification Function
(6) Abnormal High or Low temperatue Alarm Function
(4) Incubation Termination / Change Cels.& Fahr. / Return to Factory Setting
2. Before use
(1) What is an Incubation Room?
9 ~ 10
(2) How to Assemble
3. Incubation
8
(1) Incubation Installation / Incubation Start
17
5. Other Functions
(1)
Alarm for water supplement / Abnormal High or Low temperatue Alarm / Power Failure Alarm Function
7. Understanding
20
(1) Recommended temperature and humidity table by reptile during incubation
Introduction
Incubation
Product Information
How to Clean
Understanding
Function Settings
Other Functions
Before use
How to use Rcom Reptile PRO 90
(5) SET UP(Other Functions) / Easy Function Operation
Caution : Caution mark against a fault that can cause damage, trouble, or failure of incubation.
Tip : References or useful suggestions in using Rcom product
Mark Explanation
Warning of actions which may be dangerous or cause damage to the incubator.
Prohibited.
Do not disassemble.
Do not touch.
It is necessary to keep.
Remove the power cord from outlet.
Ground Connection for preventing electric shock.
The result of Hatching and Brooding can be changed by a large numbers of factors. Autoelex Co., Ltd. & our distributors will not take any responsibility for ‘Loss of eggs or pet/animal lives’ under any circumstances such as ‘Hatching/Brooding failures’, ‘User’s carelessness’, ‘Personal (un-certificated) conversion / alteration’, ‘Arbitrary using out of the machine’s purpose’, ‘Electric power failure’, or ‘Malfunctioning’. Please be sure that the machine works without any problem before placing Eggs or Pets(Animals). Also, we strongly recommend you to read the User’s Manual carefully to minimize of any failure.
DIGITAL INCUBATOR
Contents
2
North America Sales & Service www.RcomCo.com
[Main Function]
* LCD display with incubation information, and animation graphic design * Micro chip with optimum incubation conditions according to the species of repitles, for incubation beginners * Manual setting Mode for incubation specialists * Superior design with convenient operation * Optimum air circulation technique with 3 high reliability BLDC fans * Automatic Temp. & Humidity setting and control * Body locking device * Water supplement alarm function * Antiblastic Humidification method by heating water, which discourages bacterial growth * Double-glazed view window for minimizing the influence of outside temperature * Enhanced reliability by applying Swiss's Sensirion's 3rd generation temperature & humidity sensor * Powerful SMPS application for stable power supply * The function of diurnal range (D.T.G)
[Safety Function]
* Self-examination function for sensing abnormal conditions * Alarm and display function of abnormal incubator temperature caused by sudden fluctuation of ambient temperature * Incubation data memory function and power outage notification function in case of power failure * Circulation fan cover for safety and electric safety cut-out switch on the upper main body for safety * Heater supporter designed for heater tension control and its safety * Safety cover applied for protecting humidification unit * Humidification unit durability improved by water proof BLDC fan * Alarm function when water needs replenishing
[Easy Function]
* No need of separate humidification unit as it included in main body * Centigrade and Fahrenheit changing function * Easy attachment and detachment of double-glazed viewing window * Tray for incubation for exclusive use by reptile * Bottom body designed for easy cleaning * Micro chip with optimum incubation conditions according to the species of repitles, for incubation beginners
Rcom Reptile 90
First of all, we would like to express our deep appreciation for all the customers who purchased Rcom Reptile Incubator. Rcom Reptile Incubator was designed to be used easily and conveniently by the newest digital control method for controlling optimal incubation environment automatically, however, in order to get the best incubation result, at first, it is very important for users to have some incubation knowledge and right machine operation method. Therefore, before suing incubator, be sure to read instruction manual. Rcom Reptile Incubator provides the best incubation environment, however, it is necessary for users to observe and adjust each environment necessary for incubation including egg kind, temperature and humidity management by incubation date, surrounding conditions of incubator, and this product was made it possible to make the best setting for all the environments necessary for incubation.
Features of Rcom Reptile 90
Daily temperature range function means as follows : It is a function artificially making the highest time zone of temperature by sun at the natural condition, and it is a function that can raise the incubation success rate of reptile by the optimal incubation environment by raising temperature at the fixed time zone.
DIGITAL INCUBATOR
3
(1) Rcom Reptile 90 Introduction
1. Introduction
North America Sales & Service www.RcomCo.com
Electrical hazards
Be careful the details below when you use.
Do not pull the cord when taking out the power cord, and keep wet hands away from connecting plug.
Do not use a damaged power cord or loose outlet.
Risk of electric shock or fire.
Risk of electric shock or fire.
Do not insert multiple connecting plugs in an outlet.
Risk of fire or electrical overload.
Never pull the plug out of the outlet during the incubation period.
Incubation will be interrupted.
Do not twist or crush electric cord.
Risk of electric shock or fire.
Setting Cautions
Be careful the details below when you use.
Cleaning Cautions
Be sure to disconnect the electric cord from the outlet before cleaning.
Clean the incubator by a soft cloth with a neutral detergent.
Do not spray cleanser directly on the incubator surface.
Do not use chemicals like wax, benzene, alcohol, thinner, aromatic, or lubricant, etc.
Brush away dust on the plug with a dry cloth.
For special cleaning of inner part per year, contact to the service center.
If you don't clean the inside of incubator for a long time, dust can cause some trouble or a fire.
Do not install under the direct sunlight.
Do not install in dusty or dirty environment.
Risk of fire or interference with the incubation process.
Risk of damage or fire within the incubator.
Do not install in excessively cold or hot conditions, cigarette smoke, etc.
Do not install in moist or humid environment.
Risk of interference with the incubation process.
Risk of fire or electric shock.
Do not use any other non-standard parts except those provided.
Risk of damage or hatching failure.
Please ensure that no small objects get into the holes on the incubator.
Risk of electric shock or fire.
Do not disassemble or modify the incubator in any way.
Risk if electric shock or fire.
If the incubator sounds strange or emits smoke contact your service center.
Risk of electric shock or fire.
If the incubator requires repair disconnect from the power supply and please contact to your service center.
Clean the incubator thoroughly before storing.
Install away from heat sources.
Risk of damage to the incubator case and interference with the incubation process.
Do not turn the incubator upside down.
Water will pour out of the incubator, and view window can be dropped or damaged.
Ensure that the incubator is installed on a stable surface away from edges.
Risk of damage to incubator and eggs and user from accidental knocks or drops.
Do not cover the ventilating opening.
Inner temperature can rise, interrupting incubation.
Children should be super vised to ens ure that t hey do not play with the appli ance.
DIGITAL INCUBATOR
4
1. Introduction
(2) Safety Precautions
North America Sales & Service www.RcomCo.com
WATER
View Window
For a clear view of the incubation process. (Double Skin Viewing Window)
Reptile Vermi(vermiculite) and reptile eggs Loading tray.
Egg Tray
Water hole
To facilitate water top-up for the humidity control.
Main Body-1
Main Body-2
Power Connecting (the rear)
For connecting power cord.
Serial No.
(EX:RCM0000000) If you register your information with your machine’s serial number on our web-site (www.Rcom.co.kr), you can get 2 year warranty service.
For circulating warm air
Vents for air circulation
For inlet of air from outside
Air inlet vent
Digital Control Center
See description of the function and operation.
Locking Button
Identification of Parts
REAR
REAR
FRONT
Tray
Duplicated View Window
Basic Components
Main Body-1
Water Cap
Main Body-2
Power Cord
User's Manual
View Window
Reptile Vermi(vermiculite)
170g x 2 sacks
DIGITAL INCUBATOR
5
1. Introduction
(3) Identification of Parts
and Composition
North America Sales & Service www.RcomCo.com
3Hr
0.0
Gecko
26.1 80
Temp. & Humi. DOWN Setting Value Change
Other function display, Return to previous stage
Save input and Pass to next stage Setting Value Check
Down Button
Input Button
D.T.G Display
Select Reptiles Incubation Termination
Up Button
Temp. & Humi. UP Setting Value Change
Daily Temperature Gap Operation Display
Species of Reptiles
Heater Stop Display Heater Operation Display
Humidification Stop Display HumidificationOperation Display
ICON
NAME AND FUNCTION
Power Failure Notification
Current Humidity Display Humidification function OFF
Water Supplement Humidity Abnormal
ICON
NAME AND FUNCTION
40
OFF
Gecko
26.1
Current Temperature Display Temperature Abnormal Display
Daily Temperature Gap Setting Value Display
3Hr
0.0
D.T.G
**Choose a kind**
* Chameleon * Snake * Alligator * Gecko * Turtle * Tortoise * Bear.Dragon * Uromastyx * GreenPython * Python * Iguana * Others
Reptile Icon Display
Chameleon
Snake
Alligator
Gecko
Turtle
Tortoise
Bear.Dragon
Uromastyx
GreenPython
Iguana
Python
Others
Name & Function of Operation Parts
What’s ‘Temperature&Humidity Setting’? This is that you set up temp.&humi. As you want to have inside of the machine.
Select Auto/Manual Pass to next stage
Select Button
Function Button
Menu Button
DIGITAL INCUBATOR
6
1. Introduction
(4) Name & Function of
Operation Parts
North America Sales & Service www.RcomCo.com
SET UP(Other Functions)
Info
Basic information of Incubator (versoin Indication)
ALL RESET
ALL RESET
It returns to factory setting when you change the initial setting at discretion.
Alarm sounds when incubator temp. is higher than setting value because of room temp. change or heating system disorder
0.0 ~ 5.0 (0 ~ 9) [Default Setting : 0 / 1 change in degrees]
Alarm sounds when incubator temp. is higher than setting value because of room temp. change or heating system disorder
0.0 ~ -5.0 (0 ~ -9) [Default Setting : 0 / 1 change in degrees]
T.CAL
Temperature
Calibration
Unit
ALARM
ALARM
High Temp HiErr
Low Temp LoErr
Selecting Centigrade () and Fahrenheit ()
* Default Value : Centigrade ()
Sound
ON/OFF Setting for Melody, other alarms
* Default Value : ON
Light
* Always On : Always BackLight On * Event On : 20 Sec. ON with Key input
Humidity
Calibration
Abnomal
High Alarm
Abnomal
low Alarm
Factory setting
H.CAL
WARNING
Fatal Damage
with Incorrect Calibration
WARNING
Fatal Damage
with Incorrect Calibration
* Always Off : Always BackLight Off
* Default Value : Always On
LCD Backlight management setting
Easy Function Operation
How to OperateFunction Page
Automatic Mode
Incubation
11
16
16
15
15
15
12
~
14
Incubation
Termination
How to change Setting
under Incubation
Other(Manual) Mode
Incubation
℃ ↔ ℉
How to change
Screen on Incubation
How to turn off
Humidification Function
(In case of low humidity incubation)
"OFF"
2 times
Under 40%
2 Sec.
Select the Species of Reptile
Once: Temp. Setting 2 times: Humi. Setting
3 times: D.T.G Setting
Select the Species of Reptile
Temp. Setting
Humi. Setting D.T.G Setting
Screen on Incubation
System finish Are you sure?
Select YES
"All Reset"
Incubator Initialization
(Factory Setting)
℃ ℉
℃↔℉
Be sure to read CAUTIONS. We do no recommend customers to recalibrate by their own. If you need to recalibrate, please ask purchase place.
Be sure to read CAUTIONS. We do no recommend customers to recalibrate by their own. If you need to recalibrate, please ask purchase place.
Push SET UP key and then select each function icon using
UP/DOWN key(ENTER)
If you want to change setting value, keep pressing
"SET" button and change the value.
1. Introduction
(5) SET UP(Other Functions) /
Easy Function Operation
DIGITAL INCUBATOR
7
North America Sales & Service www.RcomCo.com
WATER
How to Assemble
Incubation room? It means the place where the incubator is installed and operated, and as it has much effect on incubation rate according to the environment of incubation room, it is good to install incubator at the place where there is little noise and vibration in the vicinity and the temperature range isn’t severe in the temperature of 22~25
(71.6~77). In particular, as there are many cases that the temperature falls rapidly in the nighttime differently from the daytime, it is necessary to check certainly, and during daytime, incubator must not be exposed directly to the sunlight.
When installing reptile incubator, in case that the temperature of incubation room is higher than its set temperature, the temperature control of incubator inside may not be done normally. The set temperature of incubation room should be around 4
(7.2) lower than incubator set temperature.
What is an Incubation Room?
110V~120V
Serial NO.
6
Insert the power cord in the socket at the back of the main body.
5
Lock the three locking buttons at the front and rear of the incubator.
REAR
REAR
FRONT
2
1
3
4
View Window
Tray
Main Body-2
Register Serial NO. in the back of main body (up). Free warranty period is extended to 2 years.(See 22 page)
Main Body-1
Water Cap
*
Fit the water cap.
*
Fit the water cap.
DIGITAL INCUBATOR
8
2. Before Use
(1) What is an incubation Room?
(2) How to Assemble
North America Sales & Service www.RcomCo.com
REAR
REAR
FRONT
Please be careful not to give any heavy power or shock on the heater part for humidification in the upper side of main body as it may be a cause of breakdown. Some foreign substance is created on the heater part after use, however, there isn’t any problem caused of it. (See cleaning method)
It is for making water supply be smooth when beginning incubation, and fill water for humidification in the water tank located on [Fig-1] , of downside main body.
See [Fig-7] for of [Fig.-1].
Heater part for humidification in the upper side of main
body[Fig. 2] should be submerged in the water of the inside of water tank in case of assembling with the lower part of main body. Please be sure to check and close sight glass and plug in to operate for about 30~40 minutes.
In case of using without inserting water, it is necessary to turn off its humidifying function. (See humidifying function OFF mehtod)
Environment condition of incubation room for installing reptile incubator. (temperature : 22~25 (71.6~77) / humidity : RH 30~50%)
In case of moving with water filled, as it may cause a breakdown, fill water after installing it at the place where you want to incubate.
[Fig-2]
Heate part for humidification
It has an automatic humidifying function, however, as the inside humidity of incubator depends on the water quantity mixed with reptile vermi, please be sure to check the incubation environment of reptile.
Put 2 bags of reptile vermis and 1200cc of water into tray and mix. [Fig-3]
It is possible to purchase a vermiculite for reptile incubation separately.
[Fig-1]
[Fig-3]
In case that the reptile vermi was completed dried, it may be in very dry state by absorbing the surrounding humidity of incubator inside and egg. It is good to start after understanding the required environment for each reptile kind and making previous test if incubation environment is proper to minimize incubation failure.
[ 그림-2 ]
REAR
REAR
FRONT
1200cc
Preparation for Incubation
Before inserting eggs, please start incubation after checking if all functions work without any problem by operating incubator sufficiently.
DIGITAL INCUBATOR
9
3. Incubation
(1) Preparation for Incubation /
How to Start Incubation
North America Sales & Service www.RcomCo.com
Set the environment of egg to be incubated to install the prepared tray in the inside of incubator and close the lid of sight glass tightly.
Check water for humidification every day and makeup water as seen in [Fig.-5]. Then, it is necessary to stop it when the Styrofoam ball in the inside comes up.
In case that the humidity of incubator inside isn’t controlled into high humidity of RH 90~95% according to the environment of incubation room, pour 75cc of water for humidification on each edge of 4 tray sides for incubation where without any egg meddle [Fig.-6] and pour 1000cc of water on of [Fig-7] main body(bottom).
Even though the marking humidity of incubator is normal, it is necessary to check the humidification state of vermiculite at least once a week and check the state of vermiculite once a month to makeup 400cc of water as seen in [Fig.-6].
[Fig-5]
When reptile laid eggs, they should be moved to the incubator as the first direction when laying eggs was. It is convenient to making a marking on the egg in order for them not to be changed.
In case that sight glass and water cap weren’t closed completely, temperature and humidity aren’t normally operated. Therefore, please be careful.
[Fig-4]
Marking
[Fig-7]
REAR
REAR
FRONT
1000cc
In case of humidifying inside humidity over RH 60%, be sure to fill main body(bottom) of [Fig.-7] with 1000cc of water, and in case of setting incubation humidity into less than RH 60%, it isn’t necessary to pour water on the bottom. In case of incubating at low humidity, water may be created naturally on the bottom by dew condensation. Therefore, it is necessary to check sometimes to remove it.
It is good for reptile vermi not to be reused after incubation. Incubation rate falls notably because of Bacteria contamination. [It is possible to purchase at the place you purchased.]
Bury about 1/2 of egg to be incubated in reptile vermin to fix egg. [Fig-4] (During incubation, check the state of eggs at least once a week and remove unfertilized eggs, growth-stopped eggs and moldy eggs.)
Please bury about 1/2.
[Fig-6]
100cc 100cc
100cc 100cc
DIGITAL INCUBATOR
10
3. Incubation
(1) Preparation for Incubation /
How to Start Incubation
North America Sales & Service www.RcomCo.com
3Hr
0.0
Chameleon
26.1 80
Start Incubation
3Hr
0.0
Chameleon
26.1 80
**Choose a kind**
* Chameleon * Snake * Alligator * Gecko * Turtle * Tortoise * Others
Incubation Modes
Incubation start with Automatic Mode
Press MANUAL button to select species of reptiles in basic screen.
The optimum incubation environment of the reptiles on the menu screen is memorized in the micro chip. User can incubate easily using this function.
Select species of reptiles and press ENTER button for about 2sec. then it starts incubation with automatic mode.
Basic screen before
screen starting incubation
MENU screen
Screen showing
incubation is in progress
Screen showing incubation
of other reptiles is in progress
Screen showing
completion of incubation
2Sec.
START
Auto incubation
MANUAL button (Selection of reptiles)
ENTER button (Auto incubation starts after two seconds)
ENTER button
OTHER(MANUAL) incubation (Other reptiles)
Temp. setting
Setting of temp. of early and middle stages of incubation
Humi. setting
Setting of humi. of early and middle stages of incubation
D.T.G setting
D.T.G Time setting
MENU button
UP/DOWN button (Selection of reptiles)
Incubation starts
ENTER button (incubation termination)
MENU button
UP/DOWN button ("yes" selection)
D.T.G Temp. setting
Incubation termination (under incubation)
Rcom REPTILE
PRO 90
In auto incubation, user only needs to select type of reptiles as incubation environments such as optimum temperature, humidity etc. are automatically controlled. User can change incubation environments if needed.
3Hr
0.0
Gecko
26.1 80
MANUAL SHIFT
System finish Are you sure?
YES
3Hr
0.0
Chameleon
26.1 80
3Hr
0.0
Chameleon
26.1 80
1h 90˚
3Hr
0.0
Others
26.1 80
Chameleon
Snake
Alligator
Gecko
Turtle
Tortoise
Bear.Dragon
Uromastyx
GreenPython
Iguana
Python
Others
DIGITAL INCUBATOR
(1) Incubation Modes /
Incubation start with Automatic Mode
4. Function Settings
11
North America Sales & Service www.RcomCo.com
Incubation start with Manual Mode
This mode helps users to set temperature, humidity etc. according to their needs. This mode is ideal for those persons who are experienced in incubation.
Press MENU button on basic screen.
Incubation temperature input on the menu screen is
memorized in the micro chip. User can change tempe rature randomly. [Basic memory value : it depends on reptile kind.]
Incubation humidity input on the menu screen is memo rized in the micro chip. User can change humidity randomly. [Basic memory value : it depends on reptile kind.]
Humidity setting
Temperature setting
Select the species of reptiles with UP/DOWN button and press ENTER button then it goes to incubation conditions setting mode.
Set required temperature, humidity, and D.T.G setting with UP/DOWN button, and press ENTER button to pass to next step.
If there is no proper option, please select option other reptiles, Refer to Page 14.
3Hr
0.0
Gecko
26.1 80
MENU
** Choose a kind ** * Chameleon * Snake * Alligator * Gecko * Turtle * Tortoise * Bear.Dragon
UP
DOWN
ENTER
* Press UP/DOWN button to select reptile species and press ENTER.
Temperature Setting
Temperature
Chameleon
26.1
NEXT
Humidity Setting
NEXT
Humidity
Chameleon
80%
Temperature and humidity is optimized when Rcom products are released. We do no recommend customers
to recalibrate by their own. If you need to recalibrate, please visit our website (www.rcom.co.kr→Download→
Manual) or ask purchase place. Because of low price thermometers and hygrometers are not accurate, e recommend you to use special calibrated thermo-hydrometer. (Poultry only thermo-hydrometer: check Rcom website)
(2) Incubation start
with Manual Mode
4. Function Settings
DIGITAL INCUBATOR
12
North America Sales & Service www.RcomCo.com
Hi-Temp Cycle daily
temperature range time
set screen
NEXT
D.T.G Cycle
Chameleon
3 Hour
Hi-Temp Set daily
temperature range
temperature set screen
D.T.G Set
Chameleon
1.5
START
D.T.G Set
Chameleon
1.5
START
In Daily temperature range function , user can change daily temperature range time randomly. [Basic memory value : 3 hours]
Daily temperature range time set-up
Daily temperature range temp. set-up
It is the function raising daily temperature range tempe rature of as much as daily temperature range time of above-mentioned STEP3, and in case of general reptile, its temperature is set about 1.5
(2.7℉) higher than
present incubation temperature. [Basic memory value : it depends on reptile kind.]
ex) In case of the reptile that its incubation temperature is 26.1
(78.98℉), if daily temperature range time is
set as 3 hours and daily temperature range tempera ture is set as 1.5
(2.7℉), incubation environment is
changed into 27.6
(81.68℉) once a day and for 3 hours.
Daily temperature
range set screen
Start Incubation
3Hr
0.0
Chameleon
26.1 80
[ Setting Finish and Incubation Start ]
After setting daily temperature range as the last step, press ENTER button to start Manual Mode incubation with incubation starting message/melody.
Incubation Start Notification
During Incubation
D.T.G Set
26.1 80
0.0
3H
24 Hour
Daily temperature range function means as follows It is a function artificially making the highest time zone of temperature by sun at the natural condition, and it is a function that can raise the incubation success rate of reptile by the optimal incubation environment by raising temperature at the fixed time zone.
DIGITAL INCUBATOR
(2) Incubation start
with Manual Mode
4. Function Settings
1313
North America Sales & Service www.RcomCo.com
Incubation Start for other reptiles
Press MENU button on basic screen.
Select reptile using UP / DOWN button and press ENTER
button to enter into incubation environment set-up mode.
Reset the number for daily temperature range of tempe rature and humidity with UP / DOWN button and press ENTER to save set value. [See page 12,and 13]
3Hr
0.0
Gecko
26.1 80
MENU
** Choose a kind ** * Chameleon * Uromastyx * GreenPython * Python * Iguana * Others
UP
DOWN
ENTER
* Press UP/DOWN button to select reptile species and press ENTER.
Start Incubation
Incubation Start Notification
Temperature Setting
Temperature
Others
26.1
NEXTBACK
During Incubation
3Hr
0.5
Others
26.1 90
Hi-Temp Set daily
temperature range
temperature set screen
D.T.G Set
Others
0.5
START
BACK
Humidity Setting
Humidity
Others
90%
NEXTBACK BACK
Hi-Temp Cycle daily
temperature range time
set screen
NEXT
D.T.G Cycle
Others
3 Hour
This mode helps users to set temperature, humidity etc. according to their needs. This mode is ideal for those persons who are experienced in incubation.
4. Function Settings
(3) Incubation start for
Other Reptiles
DIGITAL INCUBATOR
14
North America Sales & Service www.RcomCo.com
Parameter saved
Temp.Unit
Unit Light
Low Temp
LoErr
3Hr
0.0
Chameleon
26.1 80
3Hr
0.0
Chameleon
26.1 80
3Hr
0.0
Chameleon
26.1 80
System finish Are you sure?
YES
Finish Incubation
During incubation, press MENU button then you can see a message as "System finish, Are you sure?"
Select YES with UP/DOWN button and press ENTER.
Select or with
UP/DOWN button
Unit
Temperature unit
Fahrenheit(˚F)
Select with
UP/DOWN button
Incubation Finish
Notification
Basic Screen
Parameter saved
3Hr
0.0
Chameleon
26.1 80
When users have changed the incubator settings, but want to return to factory setting.
Press SET UP button and select All Reset with UP/DOWN button. Then, press ENTER. If you press ENTER button once again, LCD display goes off with message & alarm. Incubator returns to factory setting after about 15 sec.
Reset
Return to
Factory setting?
** WARNING **
All Reset
Sound Info
All Reset
Reset
LCD
Display
goes off
Initialization after
about 15sec
3Hr
0.0
Gecko
26.1 80
SET UP BACK
Incubation Termination
Return to Factory Setting
How to change Cels. & Fahr.
DIGITAL INCUBATOR
4. Function Settings
(4) Incubation Termination /
Change Cels.& Fahr. /
Return to Factory Setting
15
North America Sales & Service www.RcomCo.com
Incubation Condition Reset during Incubation
It is used for resetting incubation environment easily during automatic and manual incubation. In the screen during incubation, press MANUAL button to see that temperature set window flickers. To change temperature, reset its number with UP / DOWN button and press ENTER button to save set value with message/alarm sound, and move cursor to the next step(temperature and humidity daily temperature range time set and daily temperature range temperature set).
In case of not wanting to change the numerical value of incubation environment, press MANUAL button to move to the next step. Also, in case of not pressing any button for about 10 seconds, it is changed into incubation screen.
You can go directly to the needed setting mode by pressing MANUAL button several times according to your needs. It can be used when you want to check the current incubation condition during incubation.
If you press ENTER button, LCD display indicates setting Temperature & Humidity.
Parameter saved
3Hr
0.0
Chameleon
26.1 80
3Hr
0.0
HUMI. Set
26.1 OFF
In case of using without inserting water for humidification or in case of incubating at low humidity of less than RH 40%, it is necessary to stop humidifying function.
Press MANUAL button for 2 times and press DOWN button consecutively at humidity set until “OFF” is display ed and press ENTER button to turn Off humidifying function. Reversely, set into more than RH 40% to turn On humidifying function.
2 times 5 times
[Humidification ON]
3Hr
0.0
Chameleon
26.1 OFF
[Humidification OFF]
Setting Save Message
Parameter saved
3Hr
0.0
Chameleon
26.1 80
UP
DOWN
ENTER
* Press UP/DOWN button to select reptile species and press ENTER.
MANUAL SHIFT
How to Turn ON/OFF Humidification Function
In case of using without putting water for humidification in or incubating at low humidity of less than RH 40%, it is necessary to stop humidifying function. In case of not supplying water for humidification turning on humidifying equipment, the humidifying unit part is damaged or the lifespan of part is shorten noticeably. Be sure to turn OFF humidifying function equipment.
DIGITAL INCUBATOR
4. Function Settings
(5) Incubation conditions reset /
How to Set Turn ON, OFF Humidification Function
16
North America Sales & Service www.RcomCo.com
23.6 +2
Parameter saved
Parameter saved
Alarm call automatically turned off after 1min. but you should press ENTER button to switch off alarm indication.
When incubator temperature is different from setting value,
icon is changed ,and display indicates current
temp. and temp. difference alternatively.
* How to Set Abnormal High Temp. Setting (When incubator temp. is higher than setting temp.) [Setting Range: 0 ~ 5℃(0 ~ 9℉), Default Setting : 0℃]
* How to Set Abnormal Low Temp. Setting (When incubator temp. is higher than setting temp.) [Setting Range: 0 ~ -5
(0 ~ -9℉), Default Setting : 0℃]
ex : When temp. difference is 2, it indicates 23.6 and +2.0 alternatively When temp. difference is -3, it indicates 18.6 and -3.0 alternatively
When MENU screen is shown, press SET UP/ BACK button and display return to basic screen.
When MENU screen is shown, press SET UP/ BACK button and display return to basic screen.
Select with
UP/DOWN button
Set with
UP/DOWN button
High Error
High Temp. Error
over 3.0˚C
Set with
UP/DOWN button
Low Error
L Temp. Error
over -4.0˚C
High Temp. Set
H.CAL
High Temp
HiErr
Low Temp
LoErr
Select with
UP/DOWN button
Low Temp. Set
High Temp
HiErr Unit
Low Temp
LoErr
Power Failure Alarm Function
When incubator temperature is different from setting value,
icon is changed ,and display indicates current
temp. and temp. difference alternatively.
3Hr
0.0
Chameleon
26.1 80
3Hr
0.0
Chameleon
26.1 80
Water Shortage Detecting Function
When water is short, humidification icon is changed
and water supplement alarm sounds after
5 min. This alarm continues every 30 sec.
When there is any problem on water detecting sensor,
humidification icon is changed like this , and alarm sounds with message.
It takes about 1min. to return to normal display after you refill water.
What is abnormal alarm function? It is an alarm function notifying it to user in case that the temperature of incubator inside raised or decreased abnormally.
Abnormal high, Low temperature alarm setting method
DIGITAL INCUBATOR
4. Function Settings
5. Other Functions
(6) Abnormal High or Lowtemperatue Alarm Function
(1) Alarm for water supplement / Abnormal High or Low temperatue Alarm /
Power Failure Alarm Function
17
North America Sales & Service www.RcomCo.com
WATER
AUTOELEXAUTOELEX
AUTOELEXAUTOELEX
Unlock and remove the locking buttons for three parts at the front and back of incubator by pulling them forward.
When using humidification function, a lot of alien matter sticks to the humidification heating element . This may not cause failure, but when terminating incubation please clean the humidifying heater lightly with a soft brush.
If you place the main body(upper part) on the floor, please don't let the humidification heating part touch with the floor.
Dry main body(bottom) and tray after washing with water cleanly and dry main body(up) about for one day at airy area in order to remove remaining humidity in the inside completely.
In case of giving some shock on the heater part for humidification or drawing it with a sharp thing, the heater for humidification is damaged.
In order to reduce foreign substance(scale) of the heater part for humidification, it is recommendable to use distilled water as water for humidification. In case of wanting to use other water, be sure to use it after inquiring to the store purchased.
Pull out the electric cord from the connecting jack and also take out the plug from the outlet.
In case of using distilled water as water for humidification, it is possible to reduce foreign substance(scale) noticeably.
110V~120V
Back
110V~120V
In case of turning off the power immediately after using incubator, it may be a cause of breakdown because of the humidity remaining in the inside of main controller. Then, it is necessary to turn it off after operating about for 1 hour at the state of removing water for humidifi cation of the incubator inside or reoperate it after opening sight glass and naturally drying for 2~3 hours in order to use machine for a long time.
Disassembling and Cleaning the Incubator
DIGITAL INCUBATOR
18
6. How to Clean
(1) Disassembling and Cleaning the Incubator
North America Sales & Service www.RcomCo.com
WATER
REAR
REAR
FRONT
Start the vacuum cleaner to remove the dust as shown on the right and thoroughly shake out the minute dust with a fine brush.
If you finish cleaning the incubator, reassemble it in the reverse order of disassembly. Wipe out outside the main body with a wet cloth and dry it in a cool and well-ventilated place before storage.
If the incubator goes through incubations several times, dust, shell, etc. accumulate inside the main body, which may cause a break down, so be sure to clean the product before storage.
[Refer to How to assemble on Page 8.]
In case the incubator clean status is poor which may cause fan noisy or stopping.
Don't clean the product with organic solvents such as benzene, thinner, etc. which may cause deformation or decoloration.
REAR
REAR
FRONT
AUTOELEXAUTOELEX
AUTOELEXAUTOELEX
Cleaning
the fan
DIGITAL INCUBATOR
19
6. How to Clean
(1) Disassembling and
Cleaning the Incubator
North America Sales & Service www.RcomCo.com
North American King Snake
North American Milk Snake
60-65 days 28.3˚C / 83˚F 90%
60-65 days 28.3˚C / 83˚F 90%
North American Rat Snake 60-65 days 28.3˚C / 83˚F 90%
Corn Snake 55-60 days 29.4˚C / 85˚F 85%
King Snake 60-65 days 28.3˚C / 83˚F 90%
Amazon Tree Boa 40-50 days 31.1˚C / 88˚F 95%
Python 60-65 days 32.2˚C / 90˚F 90%
Iguana Green Iguana 73-80 days 29.4˚C / 85˚F 85%
Bearded Dragon Lizard 60-70 days 28.9˚C / 84˚F 85%
Uromastyx 55-65 days 33.9˚C / 93˚F 92% 1
.5˚
F/3hour
Chinese water dragon 60-75 days 29.4˚C / 85˚F 85%
Tegu 60-70 days 28.3˚C / 83˚F 90%
Lizard 50-60 days 30.6˚C / 87˚F 87%
Day Gecko 50-65 days 27.8˚C / 82˚F 75%
Gecko 50-55 days 29.4˚C / 85˚F 88-90% 1.5˚F/3hour
Alligator (Mississippiensis) 63-84 days 31.7˚C / 89˚F 95%
Crocodile (Crocodylus porosus) 89-95 days 30.6˚C / 87˚F 95%
Other Unknown Reptile 50-90 days 30.6˚C / 87˚F 85%
Alligator
Reptile Grouping SPECIES INCUBATION PERIOD TEMPERATURE
HUMIDITY
DAILY TEMPERATURE GAP
Chameleon Veiled Chameleon 145-180 days 26.1˚C / 79˚F 80%
Box Turtles 70-80 days 27.8˚C / 82˚F 85%
Sea Turtle 58-62 days 29.4˚C / 85˚F 95%
Painted Terrapin Turtle 72-80 days 29.4˚C / 85˚F 95%
Snapping Turtle 60-85 days 29.4˚C / 85˚F 95%
Turtle
Desert Tortoise 85-90 days 30.6˚C / 87˚F 80%
European Tortoise 56-84 days 30.6˚C / 87˚F 75%
Mediterranean Tortoise 56-70 days 30.6˚C / 87˚F 75%
Tor
toise
Snake
Lizard
The recommended environmental conditions as the reptiles may differ slightly.
Recommanded temp. and humi. table by reptile during incubation
DIGITAL INCUBATOR
20
(1) Recommanded temp. and humi.
table by reptile during incubation
7. Understanding
North America Sales & Service www.RcomCo.com
No signs of power to the incubator.
Try to plug-in again. Check other electric and electronic product
nearby.
Check after moving to other socket.
Check if power cord was connected well. Check power failure. Check if plug is defective.
When temperature is too high / When temperature is too low
When humidity is too high / when humidity is too low
Check set temperature. Check if FAN for air circulation doesn’t rotate. Try to make factory initialization. [See 11 page]
Adjust set temperature to wanted temperature. Unplug from socket and separate main
body to clean FAN area for air circulation with a brush or writing brush.
Refill water sufficiently.
<when low> Check if foreign substance was inserted
and close it again.
<when high> Adjust environment of incubation room. [See 8 page]
Try to make factory initialization. [See 11 page]
<When low> Check if sight window closed well.
<When high>
Check surrounding environment. Check if tray inside or main body(bottom)
contains water.
Remove all the objects put on the incubator. Move incubator to the safe place to install. Unplug from socket and separate main
body to clean FAN area for air circulation with a brush or writing brush.
Check if there is some other object on the incubator.
Check if there is some vibration on the floor or it was installed on the desk.
Check if some foreign substance was attached to FAN area after incubation.
It is normal that the machine emits some sounds because it uses air circulation fan for working.
The machine makes some noise.
As reptile incubator operates at high humidity, there is some dew on the sight window. It isn’t a breakdown but natural phenomenon.
Please install within the condition of incubation room.
Water leaks from the machine.
* In case of keeping at high humidity, there may be some dew.
Troubles Expected Causes (Possibility) Countermeasures
Before inserting eggs, please start incubation after checking if all functions work without any problem by operating incubator sufficiently.
For more detailed self-diagnosis, see Rcom homepage “SELF DIAGNOSIS” category.
Troubleshooting
All our Rcom digital products of Autoelex Co., Ltd. are made by precision systems under strict quality control. But occasionally some defective products are found on the way of their distribution.If any problem occurs, then please contact Autoelex service center or distributorsin your country. We will do our best to solve the problems, if any, for you. This product is designed in modular mode, so for its repair, if any, a qualified person can replace the part concerned with ease.
* Complaint Department : 82-55-337-2560 E-mail Receipt : Rcom@Rcom.co.kr
DIGITAL INCUBATOR
21
8.
Product Information
(1) Troubleshooting
North America Sales & Service www.RcomCo.com
AC 100~120[V], 50/60[Hz] AC 220~240[V], 50/60[Hz]
Capacity
Temp. Control Range
Outside Environment Temp.
Humi. Control Range
20 ~ 42[] / 68 ~ 107.6[℉]
Optimal range : 22 ~ 25[] / 71.6 ~ 77[℉]
(Low) 20[] / 68[] (High) 26[] / 78.8[℉]
40 ~ 95[%] (It can be changed according to the conditions)
Temp. and Humi. accuracy
±0.5[], ±0.9[] / ±5[%]
Average 48[W] Max. 65[W]
Product Size
FUSE Standard 250[V] 2.0[A] (Ø5*20[mm])
(W)500×(L)410×(H)160[mm]
Product Weight 4.35[Kg]
Power Consumption
90[eggs] (Different from the species of egg)
Power
1-1 Name : Rcom Reptile PRO 90 1-2 Model : PX-R90
Specification
Register your product Serial No. on our website for free 2 years gurantee. Refer to website for how to register. (Free 1 years gurantee in case not registerd.)
Product Registration Procedures If you are a new member of Rcom, you need to log in our website at www.Rcom.co.kr
1. Click “SIGN UP” on top of the right corner.
2. Fill out the information on the blanks.
If you already registered your information on the Rcom website, please log in to www.Rcom.co.kr.
1. Click “Login” on top of the right corner.
2. Select “Customer” and click “Register Products”.
3. Fill out the information on the blanks.
You will need below information to register on our website.
1. Your name
2. Your (home/company) address & Email address, country
3. Your product(model) name & Serial number
4. Date of purchase & Name of purchased shop you bought from
DIGITAL INCUBATOR
22
8.
Product Information
(2) Specification
North America Sales & Service www.RcomCo.com
Rcom PRO MINI Package (PX-03S)
BIRD BIRD
BIRD BIRD
Rcom MAX 20 (MX-20)
Rcom PRO 50 (PX-50)
Rcom KINGSURO MAX 20 (MX-SURO)
Rcom REPTILE PRO 90 (PX-R90)Rcom REPTILE MAX 90 (MX-R90)
Rcom REPTILE MAX 60 (MX-R60) Rcom DIGILOG
(PX-V1)
Rcom DIGILOG2
(PX-V2)
Rcom REPTILE MAX 230 (MX-R230)
Rcom REPTILE PRO 230 (PX-R230)
PUMP POWER
POWER INLET
W
A
T
E
R
P
U
LL
O
P
EN
Rcom Incubator Series
WATER
WATER
W
A
T
E
R
P
U
LL
O
P
EN
W
A
T
E
R
P
U
LL
OP
EN
PUMP POWER
POWER INLET
PUMP POWER
POWER INLET
It is possible to check additional information at Rcom homepage (www.R-com.co.kr).
North America Sales & Service www.RcomCo.com
www.RcomCo.com

SELLER

 
MANUFACTURER
● OFFICE : 218, Sangdong-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnam-do, 50805 South Korea
North America Sales & Service www.RcomCo.com
www.RcomCo.com
Loading...