Rcom KINGSURO ECO 20 MANUAL
North America Sales & Service www.RcomCo.com
Rcom Bird Egg Incubator KingSuro Eco 20 User Manual
Rcom KINGSURO ECO 20 MANUAL
EX-SURO
Ver E 1.0
4. Display
1. Safety Precautions
Electrical hazards
Do not use a damaged
power cord or loose
outlet.
Setting Cautions
Do not install in dusty or
dirty environment.
Risk of damage or fire within
the incubator.
Do not cover the
ventilating opening.
Inner temperature can rise,
interrupting incubation.
Do not pull the cord when
taking out the power cord,
and keep wet hands away
from connecting plug.
Risk of electric shock or fire.Risk of electric shock or fire.
Do not install under the
direct sunlight.
Risk of fire or interference with
the incubation process.
Install away from heat
sources.
Risk of damage to the incubator
case and interference with
the incubation process.
Never pull the plug out of
the outlet during the
incubation period.
Incubation will be interrupted.
Do not install in moist or
humid environment.
Risk of fire or electric shock.
Ensure that the incubator is
installed on a stable surface
away from edges.
Risk of damage to incubator
and eggs and user from
accidental knocks or drops.
Be careful the details below when you use.
Do not twist or crush
electric cord.
Risk of electric shock or fire.
Do not insert multiple
connecting plugs in an
outlet.
Risk of fire or electrical overload.
Be careful the details below when you use.
Do not install in excessively
cold or hot conditions,
cigarette smoke, etc.
Risk of interference with
the incubation process.
Do not turn the incubator
upside down.
Water will pour out of the incubator,
and view window can be dropped
or damaged.
Do not use any other
non-standard parts
except those provided.
Risk of damage or hatching
failure.
Children shoul d be super vised
to ensur e that they do not play
with the appli ance.
Risk of knocking the incubator
or accidental interference with
the controls.
①
● Name & Function of operation Parts
① Heater Operation Lamp
- Light on when working
② Temperature Control Regulator
- Using screw driver and turn to “+” to make
Temp. Up, and “-“ to make Temp. Down.
5. How to Assemble (Before Using)
1 2
▶ Please remove all packing from the incubator and
parts. Then, check each part is present and
undamaged. (Please keep the carton and packing
materials for repacking to retain the incubator in good
condition when not using.)
②
▶ Please put the Egg-Turning wires in the
holes, bottom outside of the main body.
Do not disassemble or
modify the incubator in
any way.
Risk if electric shock or fire.
Cleaning Cautions
Do not spray cleanser
directly on the incubator
surface.
Please ensure that no
small objects get into
the holes on the incubator.
Risk of electric shock or fire.
Clean the incubator by a
soft cloth with a neutral
detergent.
If the incubator sounds
strange or emits smoke
contact your service
center.
Risk of electric shock or fire.
Brush away dust on the
plug with a dry cloth.
Clean the incubator
thoroughly before storing.
Be sure to disconnect the electric cord
from the outlet before cleaning.
Do not use chemicals like wax,
benzene, alcohol, thinner,
aromatic, or lubricant, etc.
If the incubator requires
repair disconnect from the
power supply and please
contact to your service center.
For special cleaning of
inner part per year, contact
to the service center.
If you don't clean the inside of
incubator for a long time, dust
can cause some trouble or a fire.
※ This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
2. Identification of Parts
Main Controller
View-Window
ABS Divider
Bottom Body
Power Cab
Air Ventilation
Egg Tray
Egg Turning Wire
3. Basic components
Your Serial no. located on left-side of the main controller. Please be sure not to get dirty or break.
(ex:RCM0950278)
(Power Cap)
Rated voltage and product serial No. are marked inside of power cover.
Be sure to check this before connecting power.
▶ Loose 2 screws, connecting Main-controller and
3
View-window. And then, disassemble Main-controller
and View-window by pushing out 4 hooks on
Main-controller.
▶ Fix silicone tube which is assembled with nipple into the
hole.
Nipple
Be careful to ensure the silicon tube is not folded.
▶ Insert the nipple into the holder, located
4
on edge of main controller, and assemble
View-window and main controller with
2 screws
Please do not tighten the screws
too much.
How to cut and fold the Humidity pad properly.
5
50mm X 150mm
(Low Humidity Use : When using under 60% Humidity setting)
110mm X 150mm
(High Humidity Use : When using over 60% Humidity setting)
After cutting the Humidity pad as above sizes for your
purpose, fold up as below picture and insert it with 2 of V-pins.
High
Humidity Use
Low
Humidity Use
50mm110mm 50mm
Humidification ability is different as the pad sizes.
Please make sure that the silicon tube end is located
onto the Humidity pad.
▶ Please change the ‘50mm X 150mm sized humidity pad’ to ‘110mm X 150mm sized pad’ about
3 days before bird hatching to give much more humid environment inside of the incubator.
※ The ‘use by’ of Humidity pad is about 4~6 months, but if you use dirty water, the life of pad will be short.
(Using Distilled-water strongly recommended) Humidity pad can be purchased separately again from our shop.
▶ Please put about 100mm long silicon tube to the other end of the silicon tube nipple, made of plastic,
located outside of the incubator as below picture.
Main Controller
(1pcs.)
Power Cover fixing bolt
View-Window
(2pcs.) (2pcs.)
Main Controller Assembly Bolts
Egg Tray
(2pcs.)
V-Pin
Bottom Body
Egg Turning Wire
▶ Please put the thermometer to the V-pin as right picture.
6
If you push too strong to put the thermometer into the
V-pin, the thermometer can be broken.
Please make sure to put the thermometer just like right
picture. The sensing part of the thermometer has to be
(6pcs.)
ABS Divider
Thermometer Humidity Injector
Power Cord
(125mm)
Nipple (1pcs.)
Manual
(100mm)
Silicon Tube
(210mm * 150mm)
Humidity Pad
Hatching Pad
Screw Driver
When the spirit thermometer from KingSuro ECO has an inaccurate reading (separations look like blue dots)
caused by transit, please dip the thermometer in very warm water. When the thermometer spirit reaches
maximum, please take the thermometer out of the warm water. Please check the spirit has joined together.
The dipping method may need to be repeated to remove separations in spirit. At this time, if the water is too
7
same side with the picture. Also, the thermometer must
not be touched with Humidity pad for exact temperature
read.
▶ Please assemble Bottom-body, Tray, and Hatching-pad
order.
Ensure the Hatching-pad is placed on the Tray.
After hatching finished, be sure to wash and dry the
Hatching-pad completely for next use.
Please keep the hatching pad, and if not using the pad
during incubation, the hatching rate will be lower.
hot or maximum temperature is kept for a long time, it may cause malfunction of the thermometer.
100mm
※ Sensing part of the thermometer
has to be located opposite side with
the silicon tube out.

11. Maintenance after Hatching
North America Sales & Service www.RcomCo.com
Rcom Bird Egg Incubator KingSuro Eco 20 User Manual
6. How to install incubator
▶ Place assembled incubator on horizontal.
▶ Open the power cap to insert the power code, and then
put reassemble.
Be careful and ensure the cord not to get jammed
when you tighten screw bolt.
▶ Ensure rated voltage of the incubator ⓐ.
If you open power cap, there is sticker which tells rated
voltage in the position picture. ⓐ
▶ Check the temperature inside of the incubator before
putting eggs. When setting temperature, use the provided
screwdriver. [Ref. 10]
▶ Slowly inject water with provided syringe, and be careful
not to drop on the eggs.
If you put too much pressure on syringe or not to
inject slowly, water can be dropped on the eggs.
▶ Place eggs by adjusting tray divider according to egg
size and cover view window.
Control the space of eggs and divider optimally,
so the eggs are not interrupted for incubation.
It is recommended to place eggs
with sharp end side down.
Power Cord
▶ Newly-born birds, just after hatching are very weak for clod.
Therefore, a brooder should be ready for them. In case a brooder
is not prepared, please let them stay in the incubator for 1~2 days
after hatching. If you have a brooder, the temperature must be
around 35~37℃ (95~98.5℉) .
▶ There are differences in bird feeding due to their various species,
so please find out proper feeding before hatching.
(we have many information for bird breeding on our web-site.)
12. How to clean up after hatching finished
Be sure to pull out the power cord before clean up
incubator.
After incubation terminated, never leave the incubator
covered with the View-window because all the moisture
inside of the incubator can break electric parts, especially
PC board, and make your next hatching be failed.
Please be sure to remove the View-window and dry the
incubator perfectly.
※ Remove Main-controller from View-window.
▶ Take off all the dust and feathers using brush carefully. Please do not brush too hard. The sensor,
heater or fan can be broken.
Power Cord
When the first operated, there could be odor for
temporarily, but this is not incubator problem.
Set the eggs in the incubator, and then operate 1~2
hours to get internal temperature stable.
please calibrate temperature once.
We usually recommend higher temperature for
incubation. [37.5 ± 0.5℃]
If the view window is not closed completely,
internal temperature will not go up.
7. Egg turning
▶ Depends on eggs of birds, egg turning cycles are various.
We recommend 1 hour, and maximum of egg turning
time is 3 hours, turn right or left. During the first week,
interval of the egg turning cycle is 1 hour, and stop the
egg turning before hatch.
For automatic egg turning, you can buy optional item,
KING SURO Eggvan.
▶ Before 3 days of hatching, remove egg turning wires,
and place incubator on horizontal to stop egg turning.
While egg turing, be careful and ensure the view window is not opened nor pour eggs.
Left Right
8. Incubation Termination
※ There is no specified ON or OFF button on the incubator.
▶ Just take off the power cord after hatching.
9. Water supply for humidity.
▶ During hatching, supply water to humidity pad at least once a day.
▶ Use provided syringe, inject 15ml water through silicone tube.
Suitable installation
environment
1 time per every
5~6 hours
Temperature and humidity
at the installation site are low
[Below 20°C(68°F), 40%]
Whenever day
Humidity pad (50mm x 150mm)
Temperature and humidity
at the installation site are high
[Over 25°C(77°F), 60%]
1 ~ 2 times a day
10. How to set temperature.
▶ If you want to adjust the desired temperature,
open the power cap and turn temperature control volume
using the supplied driver.
Turn clockwise
Raise temperature
Power Cord
Before 3 days
of hatching
At the end of incubation,
exchange to high humidity
pad and inject 20~25ml
Humidity pad
(110mm x 150mm)
13. How to replace the Fuse
▶ If you have power failure even though you plug in power cord, please check
the Fuse. If you disassemble the PC board after loosening 4 screws as left
picture, there is a Fuse, and if the Fuse is damaged, please remove and
replace it.
▶ Please make sure the Fuse standard.
( 250V 2A Ø5*20mm )
▶ After replacing the Fuse, please assemble in reverse order of disassemble.
If the cover is not perfectly assembled, the rubber seals are not perfectly
block the moisture from incubation room, and this can make the PC board
broken.
You can purchase the fuse seperately at the shop, you purchased.
14. Specification
power input
power consumption
Operating serviceable temp.
Size
Weight
Fuse Standard
Incubation Capacity
The success of incubation may vary according to different factors.
The manufacturer and distributor are not responsible for failure of incubation of costly eggs, loss of
life, property damage due to negligence of user, remodeling, painting, modification of purpose of
use or power failure. Please read carefully the instruction manual before use to avoid failures.
For improvement, the functions of the incubator,
design, how to use, etc. can be changed without
notice in advance.
AC 100~120[V], 50/60[Hz] / AC 220~240[V], 50/60[Hz]
Max : 48[W]
20 ~ 42[℃] (68~107.6[℉])
(W)370×(D)231×(H)209 [mm]
2.4[kg]
250[V] 2[A] (Ø5×20[mm])
Chick : 24[eggs] Duck : 20[eggs]
Quail : 60[eggs]Pheasant : 40[eggs]
Average : 25[W]
Turkey : 9 ~ 12[eggs]
A
mazon / Macaw : 36[eggs]
Drop temperature
Turn counterclockwise
Temperature regulator can be damaged if you use unspecified tool, and repair service will be
paid.
Temperature control is very sensitive. therefore, turn it little by little.
(After setting, read temperature about 10~20 minutes later.)
In the first time when putting the eggs, adjust temperature after 1~3hours for stabilization.
Please do not turn high from the first time, raise temperature from low to high little by little carefully.
North America Sales & Service
www.RcomCo.com