4. Display
1. Safety Precautions
Electrical hazards
Do not use a damaged power cord or loose outlet.
Setting Cautions
Do not install in dusty or dirty environment.
Risk of damage or fire within the incubator.
Do not cover the ventilating opening.
Inner temperature can rise, interrupting incubation.
Do not pull the cord when taking out the power cord, and keep wet hands away from connecting plug.
Risk of electric shock or fire.Risk of electric shock or fire.
Do not install under the direct sunlight.
Risk of fire or interference with the incubation process.
Install away from heat sources.
Risk of damage to the incubator case and interference with the incubation process.
Never pull the plug out of the outlet during the incubation period.
Incubation will be interrupted.
Do not install in moist or humid environment.
Risk of fire or electric shock.
Ensure that the incubator is installed on a stable surface away from edges.
Risk of damage to incubator and eggs and user from accidental knocks or drops.
Be careful the details below when you use.
Do not twist or crush electric cord.
Risk of electric shock or fire.
Do not insert multiple connecting plugs in an outlet.
Risk of fire or electrical overload.
Be careful the details below when you use.
Do not install in excessively cold or hot conditions, cigarette smoke, etc.
Risk of interference with the incubation process.
Do not turn the incubator upside down.
Water will pour out of the incubator, and view window can be dropped or damaged.
Do not use any other non-standard parts except those provided.
Risk of damage or hatching failure.
Children shoul d be super vised to ensur e that they do not play with the appli ance.
Risk of knocking the incubator or accidental interference with the controls.
● Name & Function of operation Parts
Heater Operation Lamp
- Light on when working
Temperature Control Regulator
- Using screw driver and turn to “+” to make Temp. Up, and “-“ to make Temp. Down.
5. How to Assemble (Before Using)
1 2
Please remove all packing from the incubator and
parts. Then, check each part is present and undamaged. (Please keep the carton and packing materials for repacking to retain the incubator in good condition when not using.)
Please put the Egg-Turning wires in the
holes, bottom outside of the main body.
Do not disassemble or modify the incubator in any way.
Risk if electric shock or fire.
Cleaning Cautions
Do not spray cleanser directly on the incubator surface.
Please ensure that no small objects get into the holes on the incubator.
Risk of electric shock or fire.
Clean the incubator by a soft cloth with a neutral detergent.
If the incubator sounds strange or emits smoke contact your service center.
Risk of electric shock or fire.
Brush away dust on the plug with a dry cloth.
Clean the incubator thoroughly before storing.
Be sure to disconnect the electric cord from the outlet before cleaning.
Do not use chemicals like wax, benzene, alcohol, thinner, aromatic, or lubricant, etc.
If the incubator requires repair disconnect from the power supply and please contact to your service center.
For special cleaning of
inner part per year, contact to the service center.
If you don't clean the inside of incubator for a long time, dust can cause some trouble or a fire.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
2. Identification of Parts
Main Controller
View-Window
ABS Divider
Bottom Body
Power Cab
Air Ventilation
Egg Tray
Egg Turning Wire
3. Basic components
Your Serial no. located on left-side of the main controller. Please be sure not to get dirty or break. (ex:RCM0950278)
(Power Cap)
Loose 2 screws, connecting Main-controller and
3
View-window. And then, disassemble Main-controller and View-window by pushing out 4 hooks on Main-controller.
Fix silicone tube which is assembled with nipple into the
hole.
Nipple
Be careful to ensure the silicon tube is not folded.
Insert the nipple into the holder, located
4
on edge of main controller, and assemble View-window and main controller with 2 screws
Please do not tighten the screws too much.
How to cut and fold the Humidity pad properly.
5
50mm X 150mm (Low Humidity Use : When using under 60% Humidity setting)
110mm X 150mm (High Humidity Use : When using over 60% Humidity setting)
After cutting the Humidity pad as above sizes for your purpose, fold up as below picture and insert it with 2 of V-pins.
High
Humidity Use
Low
Humidity Use
50mm110mm 50mm
Humidification ability is different as the pad sizes. Please make sure that the silicon tube end is located onto the Humidity pad.
Please change the ‘50mm X 150mm sized humidity pad’ to ‘110mm X 150mm sized pad’ about
3 days before bird hatching to give much more humid environment inside of the incubator.
The ‘use by’ of Humidity pad is about 4~6 months, but if you use dirty water, the life of pad will be short.
(Using Distilled-water strongly recommended) Humidity pad can be purchased separately again from our shop.
Please put about 100mm long silicon tube to the other end of the silicon tube nipple, made of plastic,
located outside of the incubator as below picture.
Main Controller
(1pcs.)
Power Cover fixing bolt
View-Window
(2pcs.) (2pcs.)
Main Controller Assembly Bolts
Egg Tray
(2pcs.)
V-Pin
Bottom Body
Egg Turning Wire
Please put the thermometer to the V-pin as right picture.
6
If you push too strong to put the thermometer into the V-pin, the thermometer can be broken. Please make sure to put the thermometer just like right picture. The sensing part of the thermometer has to be
(6pcs.)
ABS Divider
Thermometer Humidity Injector
Power Cord
(125mm)
Nipple (1pcs.)
Manual
(100mm)
Silicon Tube
(210mm * 150mm)
Humidity Pad
Hatching Pad
Screw Driver
When the spirit thermometer from KingSuro ECO has an inaccurate reading (separations look like blue dots) caused by transit, please dip the thermometer in very warm water. When the thermometer spirit reaches maximum, please take the thermometer out of the warm water. Please check the spirit has joined together. The dipping method may need to be repeated to remove separations in spirit. At this time, if the water is too
7
same side with the picture. Also, the thermometer must not be touched with Humidity pad for exact temperature read.
Please assemble Bottom-body, Tray, and Hatching-pad
order.
Ensure the Hatching-pad is placed on the Tray. After hatching finished, be sure to wash and dry the Hatching-pad completely for next use. Please keep the hatching pad, and if not using the pad during incubation, the hatching rate will be lower.
hot or maximum temperature is kept for a long time, it may cause malfunction of the thermometer.
100mm
Sensing part of the thermometer has to be located opposite side with the silicon tube out.
11. Maintenance after Hatching
North America Sales & Service www.RcomCo.com
Rcom Bird Egg Incubator KingSuro Eco 20 User Manual
6. How to install incubator
Place assembled incubator on horizontal.
Open the power cap to insert the power code, and then
put reassemble.
Be careful and ensure the cord not to get jammed when you tighten screw bolt.
Ensure rated voltage of the incubator .
If you open power cap, there is sticker which tells rated voltage in the position picture.
Check the temperature inside of the incubator before
putting eggs. When setting temperature, use the provided screwdriver. [Ref. 10]
Slowly inject water with provided syringe, and be careful
not to drop on the eggs.
If you put too much pressure on syringe or not to inject slowly, water can be dropped on the eggs.
Place eggs by adjusting tray divider according to egg
size and cover view window.
Control the space of eggs and divider optimally, so the eggs are not interrupted for incubation.
It is recommended to place eggs with sharp end side down.
Power Cord
Newly-born birds, just after hatching are very weak for clod.
Therefore, a brooder should be ready for them. In case a brooder is not prepared, please let them stay in the incubator for 1~2 days after hatching. If you have a brooder, the temperature must be around 35~37 (95~98.5) .
There are differences in bird feeding due to their various species,
so please find out proper feeding before hatching. (we have many information for bird breeding on our web-site.)
12. How to clean up after hatching finished
Be sure to pull out the power cord before clean up incubator.
After incubation terminated, never leave the incubator covered with the View-window because all the moisture inside of the incubator can break electric parts, especially PC board, and make your next hatching be failed. Please be sure to remove the View-window and dry the incubator perfectly.
Remove Main-controller from View-window.
Take off all the dust and feathers using brush carefully. Please do not brush too hard. The sensor,
heater or fan can be broken.
Power Cord
When the first operated, there could be odor for temporarily, but this is not incubator problem.
Set the eggs in the incubator, and then operate 1~2 hours to get internal temperature stable. please calibrate temperature once. We usually recommend higher temperature for incubation. [37.5 ± 0.5℃]
If the view window is not closed completely, internal temperature will not go up.
7. Egg turning
Depends on eggs of birds, egg turning cycles are various.
We recommend 1 hour, and maximum of egg turning time is 3 hours, turn right or left. During the first week, interval of the egg turning cycle is 1 hour, and stop the egg turning before hatch.
For automatic egg turning, you can buy optional item, KING SURO Eggvan.
Before 3 days of hatching, remove egg turning wires,
and place incubator on horizontal to stop egg turning.
While egg turing, be careful and ensure the view window is not opened nor pour eggs.
Left Right
8. Incubation Termination
There is no specified ON or OFF button on the incubator.
Just take off the power cord after hatching.
9. Water supply for humidity.
During hatching, supply water to humidity pad at least once a day.
Use provided syringe, inject 15ml water through silicone tube.
Suitable installation
environment
1 time per every
5~6 hours
Temperature and humidity
at the installation site are low
[Below 20°C(68°F), 40%]
Whenever day
Humidity pad (50mm x 150mm)
Temperature and humidity
at the installation site are high
[Over 25°C(77°F), 60%]
1 ~ 2 times a day
10. How to set temperature.
If you want to adjust the desired temperature,
open the power cap and turn temperature control volume using the supplied driver.
Turn clockwise
Raise temperature
Power Cord
Before 3 days
of hatching
At the end of incubation,
exchange to high humidity
pad and inject 20~25ml
Humidity pad
(110mm x 150mm)
13. How to replace the Fuse
If you have power failure even though you plug in power cord, please check
the Fuse. If you disassemble the PC board after loosening 4 screws as left picture, there is a Fuse, and if the Fuse is damaged, please remove and replace it.
Please make sure the Fuse standard.
( 250V 2A Ø5*20mm )
After replacing the Fuse, please assemble in reverse order of disassemble.
If the cover is not perfectly assembled, the rubber seals are not perfectly block the moisture from incubation room, and this can make the PC board broken.
You can purchase the fuse seperately at the shop, you purchased.
14. Specification
power input
power consumption
Operating serviceable temp.
Size
Weight
Fuse Standard
Incubation Capacity
The success of incubation may vary according to different factors. The manufacturer and distributor are not responsible for failure of incubation of costly eggs, loss of life, property damage due to negligence of user, remodeling, painting, modification of purpose of use or power failure. Please read carefully the instruction manual before use to avoid failures.
For improvement, the functions of the incubator, design, how to use, etc. can be changed without notice in advance.
AC 100~120[V], 50/60[Hz] / AC 220~240[V], 50/60[Hz]
Max : 48[W]
20 ~ 42[] (68~107.6[℉])
(W)370×(D)231×(H)209 [mm]
2.4[kg]
250[V] 2[A] (Ø5×20[mm])
Chick : 24[eggs] Duck : 20[eggs]
Quail : 60[eggs]Pheasant : 40[eggs]
Average : 25[W]
Turkey : 9 ~ 12[eggs]
A
mazon / Macaw : 36[eggs]
Drop temperature
Turn counterclockwise
Temperature regulator can be damaged if you use unspecified tool, and repair service will be paid.
Temperature control is very sensitive. therefore, turn it little by little. (After setting, read temperature about 10~20 minutes later.)
In the first time when putting the eggs, adjust temperature after 1~3hours for stabilization. Please do not turn high from the first time, raise temperature from low to high little by little carefully.