rba RBA8847-100, RBA8847-428 Installation, Operation And Maintenance Instructions

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
RBA8847-100 Close Coupled Suite RBA8847-428 Close Coupled Suite Disabled Code
RBA8847-100 RBA8847-428
Date
01/11/18
Doc#
ii/rba8847-100
-428/1118
Supercedes all previous
1
Australia 1300 788 778 www.rba.com.au | New Zealand 0800 722 111 www.rbagroup.co.nz
SYDNEY | MELBOURNE | BRISBANE | PERTH | AUCKLAND
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Installation
1. Installation to be in accordance with the AS/NZ3500 series of Standards plus all local and statutory requirements. For Australia, Installation shall be in accordance with the PCA [Plumbing Code of Australia] and any relevant local authority requirements.
2. Installation to be in accordance with all local and statutory requirements.
3. Remove the access panels in the sides of the pan, using the security bit provided. Install the pan using the ‘S’ clip provided to secure the pan to the oor. Secure the pan to the wall, with suitable anchors provided by others.
4. If ‘S’ trap, make connection using the tting supplied.
5. Cut the ush pipe such that it extends 40mm beyond the inlet socket. Fit the ‘O’ ring provided as close as possible to the end of the pipe and push the pipe, allowing the ring to roll into the socket.
6. Mount the cistern, secure to the wall using the xings provided, and make the necessary water connections. Cistern ush volume has been modied to 6/3L in accordance with the manufacturer’s instructions. Ensure that the outlet compression nut is tightened.
7. Sit the cistern cover in position on top of the pan, mark the top of the cover, and the location of the holes in xing lugs on the bottom of the cover. Remove the cover and x the ‘S’ clip provided to the wall, such that it engages the return edge of the cover. Drill and plug the holes for the bottom of the cover.
8. While holding the domed cistern push buttons in position in the cover, slide the cover into position, ensuring that the ‘S’ clip is engaged. Secure the bottom of the cover with screws provided by others.
9. Check for correct operation and leaks.
10. If supplied, t the seat and replace the access panels.
11. Suite should be installed only with the cistern provided: Stylus Symphony
Water Point Location
2
Australia 1300 788 778 www.rba.com.au | New Zealand 0800 722 111 www.rbagroup.co.nz
ëí~å Ç~êÇ=é ~å
QPR=ã ã =Çáë~ÄäÉÇ=é ~å
SYDNEY | MELBOURNE | BRISBANE | PERTH | AUCKLAND
Loading...
+ 2 hidden pages