![](/html/43/4366/436634d0b90db5fdb70c5139bfa1d7dafdfb64b536bba064a22a4f5b741d8e18/bg1.png)
SPARTAN
High Power Luminaire Range Installation Guide
SPX/SPZ
Zone 1 and 21 Variant CML 17ATEX1148 & IEC Ex CML17.0074
Zone 2 and 22 Variant CML 17ATEX4149 & IEC Ex CML17.0074
Zone 21 Dust only Variant CML 18ATEX3161 & IEC Ex CML18.0087
This installation guide provides instructions for installing the SPARTAN HP Highbay/ Flood-
light series of explosion protected oodlights.
Overview
1 Safety Instructions
2 Installation
3 Maintenance
4 Technical Specication
5 Trouble Shooting
The SPARTAN HP series of explosion protected oodlights/highbay are specialist devices,
certied for use in specic operating environments.
The units must be installed in accordance with these instructions, must be correctly certied
for the specic operating environment and must be installed by suitably qualied personnel.
If you have any queries about the installation or the certication of the unit – please contact
Raytec for immediate assistance and advice.
Important information
1050-M-00052 Rev B
![](/html/43/4366/436634d0b90db5fdb70c5139bfa1d7dafdfb64b536bba064a22a4f5b741d8e18/bg2.png)
www.raytecled.com UK / Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
1. Safety instructions
1. Read this leaet carefully before commencing to install the SPARTAN unit and retain it
for future use. Installation can only be carried out by suitably qualied personnel.
2. Check the certication to ensure that the Zone, mains supply, ambient temperature
present and ‘T’ rating are suitable for the environment the unit is being installed in.
3. If the SPARTAN unit is to be installed in areas of high vibration, please consult with Raytec.
4. The SPARTAN unit housing is constructed from marine grade aluminium and toughened
glass, gaskets are silicone sponge, black encapsulant and o rings are silicone rubber,
inner domes on LEDs are polycarbonate. The end user must ensure that these materials
are suitable for the environment the SPARTAN unit will be installed in; Zone 1 and Zone 2
Hazardous areas.
5. Check certication nameplate on side of oodlight/highbay to ascertain type of threaded
cable entry on the luminaire. Select suitably certied ATEX/IEC Ex cable glands and
stopper plugs, these must be parallel thread, have a minimum of 5 full thread engagement
and be of a medium/ne tolerance to ISO965-1 and ISO965-3. The cable entry devices
selected must maintain the IP rating of the luminaire
6. The incoming mains cable should not exceed a temperature rise of 20°C above the
ambient conditions; select suitable cable.
7. To ensure the safety of the equipment, ensure that the ‘amepath’ on Zone 1 variants
are free from any corrosion. No repairs are possible to ameproof joints – if in doubt
please consult the manufacturer.
8. External fasteners must have a yield strength of at least 600N/mm2
9. On Zone 1 variants the LED assembly contains no user serviceable parts, the luminaire
must not be operated without all the individual LED polycarbonate covers in position, the
IP66 rating must be maintained.
!
Install in a well
ventilated area
Do not continually
stare at lamp
Isolate mains before
removing cover
1.5 m
![](/html/43/4366/436634d0b90db5fdb70c5139bfa1d7dafdfb64b536bba064a22a4f5b741d8e18/bg3.png)
www.raytecled.comUK / Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
2. Installation
Mounting SPARTAN Unit
1. To meet the requirements of certication a MINIMUM of 2 xing points must be used,
the xing points must be suitable for the conditions of use.
2. The line diagrams below are for guidance only – units may be mounted in any orientation
Mounting HP SPARTAN Unit – Floodlight Application
![](/html/43/4366/436634d0b90db5fdb70c5139bfa1d7dafdfb64b536bba064a22a4f5b741d8e18/bg4.png)
www.raytecled.com UK / Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
Mounting SPARTAN Unit – Highbay Application
422 (16.6")
353 (13.9")
536 (21.1")
457 (18")
13
(0.51")
33 (1.3")
172 (6.8")