Raytec RVi1120 Installation Manual

Page 1
RVi1120 120W Power Supply Installation Manual
The Raytec Model RVi1120 is a universal input AC/DC wall mount power supply. It is designed to work with the most demanding PoE Midspan devices for CCTV applications. It can provide up to 120W at 56V. It is highy reliable with sevearl internal protection circuits including Short Circuit, Overload, Over Volatge and Over Temperature. The RVi1120 is a class I power supply with earth pin. It has a buit-in active PFC circuit.
It meets the EISA 2007 Energy Independence and Security Act.
Important Safety Warning
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with a dry cloth.
- Install in accordance with the manufacturer’s instructions.
- This installation should be made by a qualified service person and should conform to all local codes.
- DO NOT bundle UTP signal wires in the same conduit as high-voltage wiring.
- To reduce the risk of fire or electrical shock, do not expose these products to rain, moisture, dripping or splashing.
- No objects filled with liquids, such as vases, shall be placed on equipment.
- DO NOT install the unit in a place where the operating ambient tempera­ ture exceeds 75° C.
- Make sure that the external power supply output voltage is in the recom­ mended range.
- Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus that produce heat.
- Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Unplug this apparatus during lightning storms or when unused for long periods of time.
- Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as a power supply cord or plug is damaged, liquid has been spilled, or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
- The mains plug is used as the disconnect device and shall remain readily operable.
WARNING! - To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases shall be placed on the apparatus.
WARNING! - This apparatus is a Class I product. This product must be connected to a mains socket outlet through an AC to DC Power supply when using DC input.
WARNING! - The mains plug is used as the disconnect device and shall remain readily operable.
Application Drawing
Network Switch
VAR-IPPOE-i8-1
RVi2202
RVi1120
Up to 60W PoE and data
VAR-IPPOE-i8-1
Midspan Connection
- Connect the DC round connector to the input of the RVi2202
AC Connection
- Plug the AC power cord provided with the unit to the mains. The Green LED will indicate the power status.
Warning: In order to turn the power supply off unplug the AC power cord from the unit and the mains.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NO
T REMOVE COVER. NO USER SERVICEABLE
RVICE PERSONNEL.
SE
The Global Leader in LED Lighting for Security and Saftey www.rayteccctv.com
Page 2
Technical Specications*
Electrical (Input)
Voltage Universal 100 ~240 V.A.C, single phase
Line Frequency 47~63 Hz
Current 1.6A Maximum
Inrush Current 80A Max./ 230 V.A.C.
Cold Start 25 degrees C @ full load
Average Efficiency >= 87% @ 115VAC and 230VAC
Power Consumption Pi <= 0.5W rated at 230VAC with no load
Power Factor Pi>= 0.9 rated at full load
Electrical (Output)
Voltage +56VDC =/-5%
Current 2.15A
Regulation 53.2V minimal ~56V typical~58.8V Maximum
Ripple/Noise 300mV Maximum
Total Power 120 Watts
Output Plug Pin Assignment Center Pin: Power
Shield: Ground
Output Pin Wire UL1185 AWG18
Drawings
Top View
Raytec
Bottom View
Side View
Ordering Information
Electrical (Protection)
Over Voltage Protection (OVP) Voltage out = 105% ~150%
Over Current Protection (OCP) Current out =105%~150%
Short Circuit Protection (SCP) Automatic recovery after fault is
removed
Power Method Switching EMI conduction & Radiation
Harmonic Current EMS Immunity EMC Directive 2004/108/EC
(EN55022/EN55024)
MTBF 50,000 hours 2 25degrees C by MIL-HDBK-217F
Environmental
Temperature Operating: 0 C (32F) ~+40C (104F)
Storage: -20C (-4F) ~+80C (176F)
Humidity Relative Operating: 20% ~ 80% RH
Relative Storage:10%~90%
Cooling Natural Air- No fan required
Mechanical
Dimensions Case: 6.6x2.3x1.5 in., 168x65.9x39 mm. (LxWxH)
Cable Length: 59 in., 1500 mm
Weight 1.3 lbs., 580g
*Specifications subject to change without notice.
Status LEDs
Ordering Information
Part No.
RVi1120
Raytec 5 Year Warranty
The warranty requires return of a product directly to Raytec in the UK. Replacement of parts or product may be new or refurbished and will meet or exceed specifications of the original parts or products.
- Registration of the product is required to validate the warranty
- Proof of purchase may be required
- The repair or replacement of a faulty product within the warranty period remains at the discretion of Raytec
The Raytec warranty covers defects in parts on workmanship but does not cover fair wear and tear, defect resulting from misuse, unauthorized modification, operation or storage outside the environment specification for the product or in-transit damage.
The warranty may only be enforced by the first installer.
Should you have any questions relating to the Warranty of any Raytec product or require any technical support please contact Raytec on 613 - 270 - 9990
120W External Power Supply
Power Green LED
TEL (+1) 613-270-9990 • FAX (+1) 613-599-5006 800 - 300 Terry Fox Drive Kanata, Ontario Canada K2K 0E3 • ussales@rayteccctv.com • www.rayteccctv.com
RoHS