Raytec RAYMAX RM200, RAYMAX RM100, RAYMAX RM50, RAYLUX RL200, RAYMAX RM25 Installation Instructions Manual

...
Raytec Technical Support: Europe / Middle East: +44 (0) 1670 528446 Americas: +1 (281) 438 3599
Narrow angle using Adaptive Illumination
Wide angle using Adaptive illumination
specifications subject to change without notice
RAYMAX + RAYLUX
Installation Instructions
Raytec Technical Support: Europe / Middle East: +44 (0) 1670 528446 Americas: +1 (281) 438 3599
Standard PSU Specifications RAYMAX Series
RM200 RM100 RM50 RM25 Input
AC 100-265 universal < 80W
AC 100-265 universal <40W
AC 100-265 universal < 20W
AC 100-265 universal < 10W
Fuse
2.5A anti-surge 2.5A anti-surge 1A anti-surge 1A anti-surge
Output
4.4A @ 13.5V 2.4A @ 13.5V 1A @ 13.5V 0.5A @ 13.5V
Adjustable Power
10% - 100% 10% - 100% 10% - 100% 10% - 100%
Weight
1.85 kg 1.65 kg 0.9 kg 0.8 kg
Dimensions L x W x D
160 x 160 x 81 160 x 160 x 81 160 x 100 x 61 160 x 100 x 61
Drilling Dimensions
4 x M4 holes @ 145 x 123mm
4 x M4 holes @ 145 x 123mm
4 x M4 holes @ 145 x 63mm
4 x M4 holes @ 145 x 63mm
RAYLUX Series
RL200 RL100 RL50 RL25 Input
AC 100-265 universal < 80W
AC 100-265 universal <40W
AC 100-265 universal <20W
AC 100-265 universal <10W
Fuse
2.5A anti-surge 2.5A anti-surge 1A anti-surge 1A anti-surge
Output
4.2A @ 14V 2.8A @ 14V 1.4A @ 14V 0.7A @ 14V
Adjustable Power
10% - 100% 10% - 100% 10% - 100% 10% - 100%
Weight
1.85 kg 1.65 kg 0.9 kg 0.8 kg
Dimensions L x W x D
160 x 160 x 81 160 x 160 x 81 160 x 100 x 61 160 x 100 x 61
Drilling Dimensions
4 x M4 holes @ 145 x 123mm
4 x M4 holes @ 145 x 123mm
4 x M4 holes @ 145 x 63mm
4 x M4 holes @ 145 x 63mm
Premium PSU Specifications
In addition to the standard functions, the Premium PSU includes 12v dc power and photocell followin g contact. See diagram below for connections.
All standard PSU’s provide current controlled output specifically calibrated for the LED head. The power supplies feature adjustable power, adjustable photocell and telemetry input.
All standard PSU’s provide current controlled output specifically calibrated for the LED head. The power supplies feature adjustable power, adjustable photocell and telemetry input.
Raytec Technical Support: Europe / Middle East: +44 (0) 1670 528446 Americas: +1 (281) 438 3599
Quick-Fit Installation Instructions:
LED unit Installation:
1) Ensure LED unit is installed in a well ventilated area.
2) Adjust horizontal target area of the LED by adjusting circular mounting bracket.
3) Adjust vertical target area of the LED by loosening the two side screws on the central bracket before adjusting to the required position.
4) To alter the angle of light projection using the Adaptive Illumination feature loosen the top bolt of the lamp by a couple of rotations. Adjust the output angle of the LED units until the required illumination is achieved then securely fasten the top bolt again.
CAUTION: DO NOT FULLY LOOSEN THE ADAPTIVE ILLUMINATION BOLT.
5) Retighten all fixings and ensure lamp is securely held in position.
6) Do not continually stare at the LED unit from less than 1.5m during operation.
7) For 200, 100 and 50 series units (RAYMAX IR and RAYLUX WL) ensure that both LED units are connected to the PSU before turning on.
8) For 300 series units (RAYMAX and RAYLUX) ensure all three LED panels are connected to the PSU before turning on.
9) For best results, set up should be done at night so results can be viewed on a CCTV monitor.
PSU unit Installation:
10) Ensure power supply is mounted securely to a flat external surface in a well ventilated area, externally.
11) Isolate the mains supply at all times whilst the lid is removed from the PSU.
12) Wire mains input and LED outputs as shown below. Check the legends on the PSU.
13) CAUTION: LED output is polarity sensitive. Black = negative (-ve). Red = positive (+ve).
14) CAUTION: For 200, 100 and 50 series units (RAYMAX and RAYLUX) connect both LED units before initializing PSU.
15) CAUTION: For 300 series units (RAYMAX and RAYLUX) ensure all three LED panels are connected to the PSU before turning on.
16) Photocell Control & Telemetry -The PSU is set-up for automatic photocell operation. If you require external telemetry input use the terminals shown on the diagram. The photocell overrides telemetry function so that lamps cannot be operated during the day. Telemetry input should be a zero volt, latched input. If no external telemetry input is required, ensure there is a wire link across terminals. Telemetry link: short circuit=lamp enabled (operated by photocell) open circuit=lamp disbled (permanently off)
17) Photocell Adjust – The sensitivity of the photocell can be adjusted by the pot shown on the diagram. It is factory set to approximately 20 Lux on, 40 Lux off.
18) To disable photocell operation wire both leads into one terminal. Note, do not insert a short circuit link between the terminals.
19) Power Control – Output power of the LED unit can be controlled by adjusting the pot as shown. Each unit is factory set to maximum power.
20) Ensure the power supply enclosure is fully sealed and watertight before operation.
Premium Functions: (Premium Power Supply Only)
18) 12v dc output is available to power camera etc. See connection diagram below. This connection is polarity sensitive Black = negative (-ve). Red = positive (+ve). Maximum output 500mA.
19) Photocell following contact – see connections below. This is a volt free connection, but is not polarity sensitive. Daytime = open circuit
Night-time = short circuit
Raytec Technical Support: Europe / Middle East: +44 (0) 1670 528446 Americas: +1 (281) 438 3599
Mains
In
LED
Output
x2
Additional Information for UL 1838 & CSA 22.2 No9.0
Suitable for indoor and outdoor use. Suitable for use in wet locations. Suitable for mounting on flammable surfaces. Suitable for combustrible surface use. Suitable for ambient not exceeding 35oC
Do not connect PSU to an ungrounded supply. Do not intall within 10ft of pool or spa. Do not use with dimmers.
Do not connect two or more power supplies in parallel. This product must be installed by a person familiar with the construction and operation of the product and
the hazards involved, in accordance with the applicable installation code. The device is accepted as a component of a landscape lighting system where the suitability of the
combination shall be determined by CSA or local inspection authorities having jurisdiction. Such systems should be protected by a ground fault circuit interrupter of the Class A type.
RAYMAX and RAYLUX
25 / 50 models:
LED Outputs Polarity sensitive
Telemetry Input – requires zero volt, latched input
Photocell Sensitivity Adjust
Power Adjust
Photocell
Main Input 100V to 240 AC
Raytec Technical Support: Europe / Middle East: +44 (0) 1670 528446 Americas: +1 (281) 438 3599
LED
Output x2
Mains In
LED
Output x3
Mains In
RAYMAX and RAYLUX
100 / 200 models:
RAYMAX and RAYLUX
300 models:
LED Outputs Polarity sensitive
Main Input 100V to 240V AC
Photocell
Photocell Sensitivity
Power Adjust
NB: The RAYMAX and RAYLUX 200 uses a different switch mode than the model shown. The model shown is the RM100 and RL100 PSU
Telemetry Input – requires zero volt, latched input
Photocell following contact – volt free, non polarity sensitive (Premium PSU only)
12v dc power output (Premium PSU Only)
LED Outputs Polarity sensitive
Universal 100-240V AC auto-sensing
Photocell
Photocell Sensitivity
Power Adjust
Telemetry Input – requires zero volt, latched input
Photocell following contact – volt free, non polarity sensitive (Premium PSU only)
12v dc power output (Premium PSU Only)