Installation and Setup Guide for
the VARIO PSU
PSU
Designed to power all VARIO illuminators (including VARIO IP)
PSU-VAR-20W-1 (small) PSU-VAR-50W-2 (medium)
PSU-VAR-100W-2 (large) PSU-VAR-150W-3 (x-large)
Contents
Page 2 - 3 Installation
Page 4 Setup
Page 5 VARIO Standard Bracketry
Page 6 VARIO PSU Specifications
Page 7 - 8 Troubleshooting

www.rayteccctv.com UK / Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
Installation
!
Isolate mains before
removing PSU cover
Install in a well
ventilated area
Do not continually
stare at lamp
1.5 m
Mount PSU to
flat surface
Warnings
1
1m - 9m
(3.3ft - 29.5ft)
Approx
Mains Lead
2
3
!
CAUTION:
Red = +ve
Black = -ve
(polarity sensitive)
Photocell
Cable
Breather
Gland
1 Select interchangeable lens and
mount VARIO illuminator
VARIO is factory set and delivered with a
35˚ beam width. To alter to 10˚, simply
remove interchangeable holographic
diffuser (IHD). To alter to 60˚, replace with
other IHD supplied.
2 Mount PSU
Mount PSU on wall/flat surface with
glands facing down
3 Connect illuminator to PSU
VARIO PSU provides 24V DC
Wiring – six core cable
Red wire +
Black wire -
Installers can extend or reduce lead
length using appropriate cable and
weather proof box

www.rayteccctv.comUK / Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
4 PSU Connections
Connect photocell following output/telemetry if required into ‘Fast Connect’ wiring terminal.
Photocell following contact - White & Yellow wires
Volt free output. Non polarity sensitive.
Terminal 1 – white wire
Terminal 2 – Yellow wire
Telemetry input - Orange & Purple wires
Volt free/dry contact or TTL input
Terminal 3 – Orange wire
Terminal 4 – Purple wire
5 Connect PSU to mains
CAUTION: Ensure cable glands and PSU lid are water tight by tightening the fixings
Golden Rules
Ensure PSU lid orientation has warning label in line
with glands (see PSU diagram, right)
Ensure PSU is fully water tight
WARNING
Automotive blade
output fuse
High quality IP66
aluminium enclosure
Slowblow
input fuse
Mains Input
‘Fast-Connect’
wiring terminal:
inc. telemetry input
and photocell
following output
Cat5
Connector
Glands x 5
White-Light LED
status indicators
Illuminator
Outputs 1+ 2
Image featuring PSU-VAR-50W-2 (medium)