Raypak XFYRE NINETY PLUS 300, XFYRE NINETY PLUS 500, XFYRE NINETY PLUS 850 Brochure & Specs

Page 1
up to
99%
Efficiency!
Can be vented with PVC
300 500 850 MBTU Models
Ultra Low Emissions
Page 2
94%
thermal efficiency!
Up to
99%
part load!
Xtreme Outdoor
Performance
XFyreCondensing Modulating Boiler
- The Green Choice
Raypak’s new XFyreis a natural extension of our successful XThermmodulating vertical boiler line
(1,1.5, 2 Million BTUH). Raypak
offers new features not found in other mod-con style boilers and combines these desirable features into one complete boiler package. XFyre is the only
condensing boiler(300 to 850MBTUH) with CSA out­door certification. Utilizing cabinet and control technology already proven in over 250,000 Raypak pool heaters,the XFyre comes to market as a seasoned veteran of outdoor environments. Mechanical engineers,architects and building owners now have extreme instal­lation flexibility, high efficiency,space saving footprint, zero side clearance,direct vent capability,PVC venting and full service access. Installers enjoy ease-of-commissioning, reliability,serviceability and long-term performance.Small space,no longer a problem. Raypak’s vertical water connections allow the units to be installed side by side,further reducing the footprint on multi-boiler installations.Our compact design makes it possible to install 6.8 million BTUH in under 67 ft
2
of floor space,plus front and rear clearance.Tie them all together with the built in Cascade Control and you have a boiler system with a 40:1 turndown that operates at 94% thermal efficien­cy! This is an Xtreme green retrofit system.
XFyre Combustion System
Modulation is nothing new to Raypak.We have be honing our gas modulation experience for over 50 years. The Raypak XFyre will pre­cisely track the heating load with its built-in Computer Control System and built-in outdoor reset function, eliminating costly over­shooting. Utilizing the latest European technology for the combus­tion-components,the optimum fuel-air ratio is maintained through­out the entire range of the load-tracking operation. Our 5:1 turn­down ensures efficiency is maintained throughout the firing rate and actually increases during part load, right when you want it! The XFyre automatically self-tunes to accommodate the widest range of gas supply pressures.The high quality integrated blower-gas valve is self-correcting and allows smooth operation with fluctuating gas supply pressures. The Raypak XFyre is cutting edge technology with atmospheric simplicity
.
Vent Flexibility
Category IV -CSA-certified 94% efficiency at full fire for hydronic boilers and 94% for domes­tic hot water supply boilers
(Up to 99% at part
load!)
When the job requires high efficiency, XFyre meets your needs.Combined vent length of up to 200 equivalent feet.Vent your project in PVC, CPVC or Stainless. XFyre is CSA certified for all three.The XFyre ships PVC ready with no extras to purchase!
Key Features
3 models from 300,000 to 850,000 BTUH
94% thermal efficiency hydronic and 94% domestic hot water
AB-1953 Low Lead Compliant
All models CSA indoor/outdoor certified
Small footprint, less than 9-1/2 square feet
Top side water connections - allows side by side installation
All models are equipped with 316L welded stainless steel heat
exchanger and copper plumbing. ASME Section IV constructed and stamped. National Board registered.
Multiple pump outputs - Boiler Pump,System Pump,
Indirect Pump
Dual flame sensing - Flame sensor and spark ignition rod
Modulating gas valve and burner,up to 5:1 turndown
Meets all current Low NOx regulations,including the new
(<20ppm) SCAQMD revisions
Whisper quiet operation
On-board diagnostic center, real English, no codes.
0-10 VDC BMS Interface (setpoint or direct drive)
Built-in cascade function for up to 8 boilers
Built-in outdoor reset functionality
Complete cabinet protects all controls and wiring
Tough rust-resistant powder coat finish
Easy to service - removable air filter
PVC-CPVC-Stainless vent certified
Suitable for altitudes up to 10,000 ft. (derate may apply)
Options
Outdoor air sensor (B-32)
Indirect sensor
TruSealdirect vent kit (D-21 factory installed,D-22 Loose)
PC interface cable
Condensate neutralizer (Z-12)
Page 3
3
1
2
3
4
5
8
7
6
9
10
14
4a
1.Water Inlet
As low as 50°F entering.All copper and brass factory installed vertical plumbing connections.Vertical plumbing allows boilers to be installed side by side or in tight places if need be.Male NPT connections.
2.Water Outlet
All copper and brass factory installed vertical plumb­ing connections.Male NPT connections.
3. Low Voltage Wiring Board
Allows easy front access to thermostat connections, Outdoor sensor, DHW sensor, Alarm contacts and BMS input signal
(0-10VDC). Built-in cascade control using
CAT 3 or CAT 5 computer network cables to connect with the communication bus between boilers.Every unit comes factory equipped with Cascade control. Simply remove the front door for quick access and daisy chain the boilers together.
4. Control Cover
Helps prevent sun damage to the LCD display and protects the control panel from dust, dirt and water.
4a. Control Interface
Easy to use microprocessor control with a 2x20 LCD scrolling display.Monitor flame strength
(␮〈), fan
speed(RPM),BMS input signal(0-10V),sensor temps and setpoints.Built-in outdoor reset feature saves energy­requires optional outdoor air sensor. Control also pro­vides indirect priority function. Full diagnostic control constantly monitoring 18 events.Fault code history records the last 10 fault events and can be recalled to help with troubleshooting. Well thought out ergonomic control pad gives tactile feedback to the user. No need to second guess your actions,wonder­ing if you have engaged the buttons or not.The user is reassured with a tactile pop every time a button is successfully toggled. Everything you need from set-up to service is at your fingertips,and all in one location.
5.Air Fuel Ratio Gas Valve
XFyre uses a German, precision manufactured, main gas valve considered by most to be second to none. This high tech gas valve works in perfect unison with the combustion air blower. The result is smooth and quiet light-offs while delivering a 5:1 turn down.
850:170MBTU 500:100MBTU 300:60MBTU
With this much flexibility,XFyre is the right boiler for almost any size job.
6. Intake Air Filter
Every XFyre comes standard with a front access, removable media,combustion air filter.
7. Manual Reset High Limit
8. Condensate Trap
The XFyre has a built-in condensate trap located at the rear of the unit. The trap and the overfill conden­sate sensor are accessible through their own access panel.
9.Vent Switch
Senses possible obstructions in the flue vent pipe.
10. Flow Switch
The XFyre keeps its flow switch safe and dry inside the cabinet, which protects it during shipping and in the boiler room.
11. “Duo” Style Heat Exchanger
The XFyre uses a combined 316L stainless steel pri­mary and secondary heat exchanger. Weld-sealed technology eliminates gaskets and o-rings.Special glycol is not required for hydronic applications.ASME Section IV constructed and stamped. National Board registered.
12. Direct Spark Ignition
XFyre's state-of-the-art combustion control system utilizes the finest dual electrode igniter to start the combustion cycle.After ignition,the spark rod also acts as a second flame sensor.
12a. Flame Sense Electrode
After a call for heat, a seperate flame electrode moni­tors flame rectification. This helps to ensure proper carry over while also constantly monitoring the flame over 50 times every second.
13. Internal Tru-SealConnection
Allows the XFyre to be direct vented up to 200 com­bined equivalent feet (vent and air intake) in a hori­zontal or vertical vent system.
14. Smart Blower Technology
Utilizing a whisper quiet, all metal, technologically advanced combustion blower. Air and fuel are mixed precisely by the computer control center.
15. Mounting Feet
Built-in mounting feet located right under the center of gravity allows for quick and easy Tapconanchor­ing.
16.Weather-Proof Jacket
Heavy gauge galvanized steel with a UV-resistant Polytuf powder coat finish is impervious to weather and corrosion. Raypak has one of the finest, top-of ­the-line powder coat systems on the west coast regardless of industry. We laugh at a 1000 hour salt spray test. Independent test documentation available upon request.
Think Raypak
Think Green
Model 850 Model 300
12a
5
15
11
12
13
14
Page 4
4
1. Flue Outlet
Category IV- PVC,CPVC and Stainless steel certified. The XFyre ships PVC ready,no extras to purchase!
2. High Voltage Wiring Box
120VAC main incoming power connections. Boiler pump wiring and DHW pump wiring. Alarm power out.
3. Gas Inlet
The XFyre will operate at 100% full rate with gas pres­sures as low as 4.0”w.c.
4. Condensate Drain and Trap
3/4”-NPT PVC connection for condensate removal. Inset photo shows condensate trap,overfill sensor and pressure switch for the flue.Raypak offers optional condensate neutralizer kits (option Z-12) that can be plumbed between the heater and the drain.
5. Direct Vent Capability
Every XFyre is direct vent capable.By installing an optional combustion air pipe adapter, your XFyre is ready for direct vent. For factory installation,order (option D-21) TruSealat time of order.
6. Rating Plate Location
7. Gas Valve and Boiler Control
Raypak uses German-made,high quality Dungs gas valves,considered the finest modulating gas valves produced today. To the right of the gas valve is the boiler computer control center, which always keeps the blower, gas valve,direct spark ignition and flame supervision in perfect harmony.
8. Inlet and Outlet Connections and Flow Switch
The vertical inlet and outlet connections are all copper and brass fitted with male pipe thread connections. The flow switch is fully contained within the cabinet, protecting it from the elements and boiler room mishaps.Servicing of the Flow switch can be done from the top or left side.
9. Removable Air Filter
Simple front access; just remove the front door. The fil­ter just slides right out for quick and easy inspection and replacement.The high capacity filter is rated MERV 8.
Xtreme Access
7
8
4
9
The XFyre is purpose built for the
contractor and service professional.
Loosen wing-nutsRemove Front Door Pullout filter media
FRONT ACCESS INTAKE AIR FILTER
1
Completely serviceable from the front, top and both sides!
1
2
6
3
4
5
Page 5
Xtremely Small Footprint
Ratings shown are for elevations up to 10,000 feet.For installations at elevations above 2,000 feet, derate may apply,please consult the factory for additional instructions.
CLEARANCES
Front 24” 24” Rear 24” 24” Right 0” 0” Left 0” 0” Top 12” 24” Floor 0” --­Vent 1” ---
Certified
Minimum
Service
Minimum
*Do not install on carpeting Note: Local codes may require increased clearances
Heater
Side
Note: Current draw (Amps) is for pump only Water hardness grains per gallon
Soft = 0-4 • Medium = 5-15 • Hard = 16-25 Water above 15gpg requires water softner.
Model
MBTUH
Input
Boiler
Output Efficiency
Water Heaters
Output Efficiency
MBTUH
Input
Minimum
Input
MBTUH
300 300 282 94% 300 282 94% 60 500 500 470 94% 500 470 94% 100 850 850 799 94% 850 799 94% 170
Model
Dimensions (in.)
A
Length
Amps*
PHYSICAL DATA
300 28 - 1/4 16 - 1/2 27 - 9/16 3/4 1 - 1/2 4 4 3 410 6.6 3 500 37 - 1/4 16 - 1/2 36 - 1/4 1 1 - 1/2 4 4 3 505 7.9 4 850 54 - 1/4 28 53 - 9/16 1 - 1/4 2 6 6 19 - 3/8 580 9.5 5
Foot-
Print
(ft
2
)
Ship
Weight
(lbs.)
E
F
Mounting
G
NPT
H
NPT
K
Flue Ø
T
C/A
Ø
V
300 1/8 1.3 1/4 5.7 500 1/8 1.3 1/2 6.9 850 1/2 6.9 1 14.0
Soft
Water Heater Pump Sizes
HardMedium
HP Amps HP AmpsHP Amps
XFyre
Model
*Current Draw is for heater only. (Supply breaker must have delayed trip.)
Do not use when hardness exceeds
15 grains per gallon
1-1/4
2-1/2
5
8-1/2
TOP VIEW
H WATER INLET
H WATER OUTLET
9/16” MOUNTING HOLES 4X
F
LEFT VIEW FRONT RIGHT VIEW REAR
22
SCROLL
SCROLL
ENTER
ESC
MENURESET
TM
32
12-3/4
6-3/4
A
1° JACKET TOP SLOPE
T COMBUSTION AIR
CONNECTION (OPTIONAL)
6-3/4
2-3/4
K FLUE CONNECTION
7/8” ELECTRICAL CONNECTIONS
G GAS
3/4” NPT PVC CONDENSATE DRAIN CONNECTION
25-3/4
E
7
V
4-1/2
13
Page 6
6
Xtremely Easy to Wire
300 28 17 19 8 14 5 14 5 40 36 27 17 500 47 16 31 7 24 4 24 4 40 56 24 18 850 80 40 53 17 40 10 40 10 40 80 40 20
XFyre
Model
20°F
GPM
T
40°F30°F
Minimum Flow*
Rates Of Flow And Pressure Drops
TYPE W
300 1693 1128 846 677 564 484 423 376 339 500 2821 1881 1411 1128 940 806 705 627 564 850 4796 3197 2398 1918 1599 1370 1199 1066 959
Temperature Rise (°F)
XFyre
Model
10080 9060 70
40
50
30
20
Recovery Rates
300 30 19 8 1.5 9 23 25 14 1.5 15 500 30 31 7 2 9 20 47 16 2 20 850 31 51 16 2 20 24 67 28 2 36
Soft
(0-4 Grains Per Gallon)
Water Hardness
Hard
(16-25 Grains Per Gallon)
Medium
(5-15 Grains Per Gallon)
XFyre
Model
Maximum Flow
GPM
T
TYPE HTYPE W
*Closed systems only
P
P
GPM
P
GPM
P
GPM
P
T P
MTS
T
GPM SHL GPM MTS⌬PSHL
Do not use when hardness
exceeds 15 grains per gallon
MTS = Minimum Tube Size, inch. SHL = System Head Loss,ft (based on heater and tank placed no more than 5 ft apart). T = Temperature rise,
°F
P = Pressure drop through heat exchanger, ft
Hydronic Boiler
Hot Water Supply Boiler - DHW
T
GPM MTS⌬PSHL
120VAC Wiring Center
The XFyre’s 120VAC wiring center is located on the rear of the boiler.All incoming line voltage and pump wiring are contained away from the 24v control wiring.Wiring the boiler is simple and straight forward.
Low Voltage Wiring Center
Just like its big brother the XTherm, the XFyre has a separate front mounted wiring center for all of the low voltage connections.This makes thermostat, water sensor,0-10VDC BMS,and alarm contacts a breeze to set up.No more guessing where the contact points are buried in the boiler. Built-in cascade control using CAT 3 or CAT 5 computer network patch cables to connect with the communication bus between boilers. Simply remove the front door for quick access.
120VAC Wiring Center
(rear of boiler)
Low Voltage
Wiring Center
Page 7
7
Boiler Control and On-Board Diagnostic Center
Raypak’s XFyre comes equipped with a microprocessor control center that displays its information on a 2x20 character LCD display in plain English. All set-up and programming is done at this interface.Control monitors boiler system status including safeties,ignition faults and also stores up to 10 reported faults. The diagnostic center even monitors and reports the flame strength signal in microamps.Monitor blower speed, BMS input and all water and air sensors. A normally-open and nor­mally-closed dry contact alarm relay is provided.
Outdoor Proven
Raypak is no stranger to the outdoor environment. Our touchpad is 100% waterproof and has been proven and perfected on our pool products.No guesswork here,just one tough boiler ready to take on jobs that others have to walk away from.
Safety Faults
Condensate Full
Outdoor Sensor
Line Voltage
Blocked V ent
Low Water Level
24 Volt Low
Low Water Flow
Temper Blocking
High T emperature
Flue/Gas Pressure
Supply Thermistor
Return Thermistor
Supply High
Ignition Control Faults
No Flame
Flame Failure
Flame When Off
Fan Speed Error
Xtreme Control
Example Diagnostic Fault Report
Diagnostic Information
Xtreme Firing Rates
Cascade up to 8 Boilers Deliver up to 6.8 Million BTU at a 40:1 turndown rate!
The XFyre comes standard with a built-in Cascading Boiler Control.No other controls to buy,just daisy chain the units together with CAT 3 or CAT 5 computer network cables
(not supplied)
that plug into the front mounted communication bus on each unit
(see low voltage wiring box opposite page)
. Designate a Cascade Master Boiler and set all the other boilers as Followers. It’s that sim­ple! The XFyre has built-in Lead-Lag control.This allows rotation of the starting boiler so all boilers in the system remain active and the run times remain equal on each unit. Rotation can even be programmed based on time, ensuring equal run times per unit.
 
Page 8
HEAT EXCHANGERJACKETOTHER
GAS TRAIN
SAFETIES
OPERATING CONTROLS
ASME Section IV,National Board Registered, 160 PSI • H Stamp Heat Exchanger Tubes • 316L Stainless Steel Stainless Steel • CSA Verified AB-1953 CA low lead compliant
Pressure Relief Valve • 60 PSI (loose) • 125 PSI
• 30, 45,75, 150 PSI Temperature & Pressure Gauge (Loose) Pump • 120V, Single-Phase
Indoor/Outdoor Certified Vent Terminal • Outdoor
• Through-the-Wall Fully-Enclosed Controls Combustible Floor Rated
120V Power Supply On/Off Switch Programmable Pump Time Delay,Single-Phase • Included in Controller Terminal Block Connections • Enable / Disable
(Front mounted) • 0-10 VDC Setpoint/Direct Drive Input
LCD diagnostic display with 10-Event History (2x20 character display, reads in plain English) Temperature Controller with 3 Water Sensors • (up to 5:1 Turndown)
• Outdoor Reset Sensor N/A Multiple Boiler Controller • TempTracker Mod+ Hybrid,up to 16 boilers
Direct Spark Ignition System • 1-try
• 4-try High/Low Gas Pressure Switches Blocked Vent and Air Pressure Switches High Limit Switch • Manual Reset,Fixed
• Automatic Reset, Fixed Low Water Cut-Off, 24V • With Manual Reset and Test Buttons
Flow Switch
Modulating Combination Gas Valve Combustion Air Blower Additional Safety Valve • Motorized (externally mounted)
• Solenoid (externally mounted) CSA-Certified Efficiency • 94% at Full Fire
• 99% at Part Load Air Filter TruSeal Direct-Vent Alarm Contacts CSD-1 / GE GAP Control System Low NOx • Meets all current requirements Condensate Drain and Trap Condensate Neutralizer
Hot Water
Supply Boilers
(Type W)
Boilers
(Type H)
= Standard = Optional
Raypak, Inc. • 2151 Eastman Avenue,Oxnard, CA 93030 • phone: (805) 278-5300 • fax:(800) 872-8725 • www.raypak.com
© 2009 Raypak, Inc. Cat. No.1000.22 Effective: 01-01-10 Replaces: New
TM
Loading...