Raypak R6350ti-E-PD Service Manual

Technical Data
Classic Series Heat Pump Pool Heaters
Specialty Models
odel
M
350ti
6 8350ti
A
2-1/2”
4 42-1/2”
MODEL R6350ti-E-PD R6350ti-E-HC R8350ti-E-HC
Heat BTUH Output 117,000/113,000 110,000/104,000 133,000/125,000
AHRI 1160* (80,80,80) / (80,63,80)
C.O.P. 6.2/6.0 6.0/5.7 5.5/5.2 Compressor Scroll Scroll Scroll Refrigerant R-410A R-410A R-410A Voltage 208/230V-1Ph-60Hz 208/230V-1Ph-60Hz 208/230V-1Ph-60Hz Minimum Circuit Ampacity 42 42 42 Maximum Breaker Size (Amps) 60 60 60 Electrical Input (kw) 5.5 5.3 7.0 Heat Exchanger Titanium Titanium Titanium Water Flow (gpm) 15-60 15-60 15-60 Shipping Weight (lbs.) 310 319 368
*Tested to AHRI 1160 All models comply with Florida 4.0 minimum C.O.P. requirement.
Model Designation
R = Raypak Brand
6 = Approximate Tonnage
3 = Classic Cabinet Design
5 = Model Revison
PD = Power Defrost HC = Heat Cool HS = Heat System
A = Analog Control E = Digital Control
ti = Titanium Heat Exchanger
0 = 1 phase 208/230V 3 = 3 phase 208/230V
Swimming Pool and Spa
Heating Products
The Pool and Spa Heating Experts
sm
Technical Data
Classic Series Heat Pump Pool Heaters
Classic Model Standard Features
abinet
C
• Exclusive DuraSteelTMPowder-Coated Cabinet
Polyester powder-coated, non-corrosive cabinet is more durable than plastic heat pump cabinets. Same rugged steel construction used by all the major air conditioner manufacturers.
Evaporator Coil
• Large Air Coils
Raised lanced-fin design maximizes heating at lower temperatures. Raypak engineered coils are highly optimized to meet our specific design requirements. From the proper fins per inch to advanced distribution circuiting. We are the only heat pump pool heater company to actually manufacture our own coils.
• Venturi Fan Cowling
High-capacity 3000-cfm fan provides unrestricted air flow for better heating. Precision engineered and manufactured cabinet design eliminates unwanted air gaps. This means more air over the coil which translates to greater efficiency.
Compressor
• Scroll Compressor
Scroll compressors are quiet and efficient compared to piston type compressors. They provide higher efficiency, lower sound levels, superior durability and unsurpassed reliability. The unique design of a scroll compressor actually wears in over time, not out!
• Sound Isolation Pads
Prevents sound transfer to equipment pad and elevates the base pan to improve water drainage. Its the little details like this that make Raypak products stand out from the crowd.
Heat Exchanger
• Spiral Titanium Tube
Our spiral titanium tube heat exchanger provides a corrosion-free waterway that can withstand the abuses of harsh pool chemistry. The spiral tube helps reduce deposit build-up and increases efficiency by performing a “scoop­and-lift” action.
• Internal Bypass Valving
Automatically compensates for normal day-to-day changes in your pool’s hydraulics, maximizing heat transfer efficiency.
• Plumbing Connections
Off-set 2” PVC union connections are included for ease of installation.
ontrols - Digital
C
• Pool/Spa Control
Your digital heat pump pool heater can
e set to have a different target
b temperature for your pool and spa. This
llows you to dial in just the right spa
a temperature and never have to adjust it again. The pool can be set to a lower, more energy saving temperature.
• Remote Compatible
The digital heat pump pool heater can be easily controlled by most two-wire and three-wire remote systems.
• On Board Diagnostics
Tells the homeowner if there is a problem. Provides the service technician with detailed diagnostic information.
Heat-Cool Models
Controls
• Heat-Cool Selector Switch
Go from heat mode to cool with a push of a button.
Refrigerant Circuit
• Reversing Valve
Heat-Cool units have a unique reversing valve that allows the heat pump pool heater to cool the pool water during the hot summer months.
• Defrost
Heat-Cool units have the unique ability to prevent ice from forming on the condensing coil. If freezing temperatures are sensed on the coil while heating, the unit can switch to the cooling mode. During the cooling mode, the refrigerant will be warmed by the pool water and send the hot gas to the evaporator coil to melt the ice. Once the coil temperature returns to a normal operating temperature, the unit resumes heating the water. This process only takes about 4 to 6 minutes to complete.
Power Defrost Models
Refrigerant Circuit
• Hot Gas Bypass Valve
If the condensing coil senses freezing temperatures while running, the power defrost feature will activate and allow some of the hot Freon gas to bypass the water heat exchanger and re-route it back through the condensing coil. This unique feature allows the unit to continue heating the water while it removes any ice that may have formed on the coil. This feature is a great benefit when trying to operate at lower ambient temperatures.
In keeping with its policy of continuous progress and product improvement, Raypak reserves the right to make changes without notice
Swimming Pool and Spa
Heating Products
6000.18.4F • 01-15-15
Loading...