Commercial
Pool Heaters
Rugged, efficient heaters for large pools
Clubs. Universities.
Municipalities. Watersport
Centers. Large residential pools.
23 model sizes — 511,500 to
4,000,000 BTUH inputs.
Indoor and outdoor styles.
80-82% thermal efficiency.
Natural or propane gas.
Fuel-saving electronic ignition.
Precision water temperature control to ± 1°F.
Low operating cost. Low maintenance cost. Easy service.
These heaters are design certified and tested under the requirements of ANSI Z21.56 / CSA 4.7 American National Standard / CSA Standard for Gas-Fired Pool Heaters. Only Raypak offers a pool heater that is not only the most efficient (up to 82% thermal efficiency) but also includes, engineering and manufacturing innovations not found in other makes. As a result, a Raypak commercial pool heater is unmatched for heating efficiency, operating economy, low-cost installation and all-around dependability. And they are fired up and fully tested at the factory to assure their on-site performance. Check these standard features and see why Raypak is the best!
Electronic Pilot Ignition…Saves fuel, no standing pilot.
100% Copper And Bronze Waterways…Bronze headers and cupro nickel finned tubes prevent corrosion and rust which can stain the pool and destroy the heater.
1"DiameterFinnedCuproNickelTubes…Better water flow, lower pressure drop through heater.
Tough, Durable Polytuf Powdercoat Finish…Long-lasting all-weather protection in durable Forest Green color.
MODEL P-1336 INDOOR
Unitherm Governor…For Models P-514 thru P-1223, a patented 3-way valve built in the header, automatically maintains the water in the heater at the precise temperature that prevents condensation and scale.
By-Pass Pump…For models P-1287 thru P-4001, a properly designed by-pass pump is used to control the temperature of the water entering the heater to avoid condensation and scaling.
Interlocking Combustion Chamber…Cuts heat loss for best efficiency. Keeps jacket cool.
Dual Gas Valves…For safety.
Stainless Steel Burners…Can't clog or corrode. Slide-out Burner Tray…For easy inspection.
Protecto Vent Top (outdoor only)…Wind,rain and debris proof.
L
W
Catalog No. 6200.10-P |
Effective: 12-01-07 |
Replaces: 05-15-03 |
SPECIFICATION AND DIMENSIONS
|
MBH NATURAL GAS (X 1000) † |
|
|
DIMENSIONS (INCHES) |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
APPROX. |
MODEL |
INDOOR |
OUTDOOR |
|
HEIGHT |
JACKET |
GAS |
WATER |
|
FLUE |
|
SHIPPING |
||
|
INPUT |
OUTPUT |
INPUT |
OUTPUT |
WIDTH |
OVERALL |
HEIGHT |
CONN. |
CONN. |
|
DIA. |
|
WEIGHT |
|
|
|
|
|
A |
B |
C |
G |
H |
J |
K |
L |
(LBS) |
P-514 |
511.5 |
419.4 |
511.5 |
419.4 |
32-3/4 |
57 |
33 |
1 |
2 |
|
10 |
25-3/8 |
450 |
P-624 |
627.0 |
514.0 |
638.0 |
514.0 |
37-1/2 |
57 |
33 |
1 |
2 |
|
12 |
20-1/2 |
480 |
P-724 |
726.0 |
595.0 |
726.0 |
595.0 |
41-5/8 |
57 |
33 |
1 |
2 |
|
12 |
34-1/4 |
510 |
P-824 |
825.0 |
676.5 |
825.0 |
676.5 |
45-3/4 |
57 |
33 |
1 |
2 |
|
14 |
38-1/2 |
590 |
P-926 |
|
|
926.0 |
759.0 |
52-3/8 |
|
|
1 |
2 |
|
|
|
700 |
P-962 |
961.7 |
788.6 |
|
|
52-3/8 |
76-1/8 |
33-1/2 |
1 |
2 |
23-5/8 |
14 |
28 |
650 |
P-1083 |
|
|
1083.0 |
888.0 |
59-1/4 |
|
|
1 |
2 |
|
|
|
810 |
P-1125 |
1124.7 |
922.0 |
|
|
59-1/4 |
78-1/8 |
33-1/2 |
1 |
2 |
23-5/8 |
16 |
32 |
750 |
P-1178 |
|
|
1178.0 |
966.0 |
63-5/8 |
|
|
1 |
2 |
|
|
|
800 |
P-1223 |
1222.5 |
1002.4 |
|
|
63-5/8 |
78-1/8 |
33-1/2 |
1 |
2 |
23-5/8 |
16 |
32 |
855 |
P-1287 |
|
|
1287.0 |
1055.0 |
68-5/8 |
|
|
1-1/4 |
2-1/2 |
|
|
|
975 |
P-1336 |
1336.6 |
1096.0 |
|
|
68-5/8 |
80-1/8 |
33-1/2 |
1-1/4 |
2-1/2 |
23-5/8 |
18 |
36 |
970 |
P-1414 |
|
|
1413.0 |
1158.5 |
74-7/8 |
|
|
1-1/4 |
2-1/2 |
|
|
|
1065 |
P-1468 |
1467.0 |
1203.0 |
|
|
74-7/8 |
80-1/8 |
33-1/2 |
1-1/4 |
2-1/2 |
23-5/8 |
18 |
36 |
1050 |
P-1571 |
|
|
1570.0 |
1287.0 |
81-1/8 |
|
|
1-1/4 |
2-1/2 |
|
|
|
1120 |
P-1631 |
1630.0 |
1336.6 |
1758.0 |
|
81-1/8 |
83-1/8 |
36-1/2 |
1-1/4 |
2-1/2 |
23-5/8 |
18 |
36 |
1100 |
P-1758 |
|
|
|
1441.5 |
89-3/8 |
|
|
1-1/4 |
2-1/2 |
|
|
|
1140 |
P-1826 |
1825.6 |
1497.0 |
|
|
89-3/8 |
85-1/8 |
36-1/2 |
1-1/4 |
2-1/2 |
23-5/8 |
20 |
40 |
1190 |
P-2100 |
2100.0 |
1722.0 |
|
|
61 |
68-1/4 |
|
1-1/2 |
3 |
|
24 |
|
1580 |
P-2500 |
2499.0 |
2049.0 |
|
|
70 |
68-1/4 |
|
1-1/2 |
3 |
|
26 |
|
1780 |
P-3001 |
3000.0 |
2460.0 |
|
|
81-1/4 |
68-1/4 |
|
2 |
3 |
|
28 |
|
2000 |
P-3500 |
3500.0 |
2870.0 |
|
|
92-1/2 |
68-1/4 |
|
2 |
3 |
|
30 |
|
2180 |
P-4001 |
4000.0 |
3280.0 |
|
|
103-3/4 |
68-1/4 |
|
2 |
3 |
|
32 |
|
2500 |
Electrical Rating: 120/24V 60 Hz less than 12 amperes. |
Ratings shown are for elevations up to 2000 feet. Elevations over 2000 feet ratings |
||||||||||||
† See gas conversion chart. |
|
|
|
should be reduced at the rate of 4% for each 1000 feet above sea level. |
|||||||||
* Manufactures rating. |
|
|
|
‡ Note: Addition of special controls for CSD-1, IRI and others may increase gas train |
|||||||||
|
|
|
|
|
|
size. Consult with the factory. |
|
|
|
|
MINIMUM CLEARANCES FROM
COMBUSTIBLE CONSTRUCTION
|
|
|
LEFT |
RIGHT |
|
TOP |
MODEL |
FRONT |
REAR |
SIDE |
SIDE |
INDOOR |
OUTDOOR |
P-514 TO |
24" |
12" |
6" * |
6" |
36" |
UNOBSTRUCTED |
P-824 |
|
|
|
|
|
|
P-926 TO |
24" |
24" |
24" |
24" |
24" |
UNOBSTRUCTED |
P-1826 |
|
|
|
|
|
|
P-2100 T0 |
48" |
24" |
24" |
24" |
24" |
MODELS ARE |
P-4001 |
|
|
|
|
|
INDOOR ONLY |
* 18" REQUIRED FOR SERVICING
†TO CONVERT NAT. GAS MBH TO PROPANE MBH
MODEL |
MULTIPLY NAT. MBH |
|
BY |
P-514 TO P-824 |
0.94 |
P-926 TO P-1828 |
0.92 INDOOR |
|
0.955 OUTDOOR |
P-2100 TO P-4001 |
1.0 (SAME AS NAT. GAS) |
RECOMMENDED FLOW RATES
MODELS |
MINIMUM |
MAXIMUM |
P-514 TO P-1223 |
60 GPM |
120 GPM |
P-1287 TO P-1826 |
SEE FLOW RATES |
|
P-2100 TO P-4001 |
TABLE BELOW |
|
MODELS |
FLOW RATES (GPM) |
|
1287/1336 |
30-50 |
|
1414/1468 |
35-55 |
|
1571/1631 |
40-65 |
|
1758/1826 |
45-70 |
|
2100 |
50-80 |
|
2500 |
60-95 |
|
3001 |
75-115 |
|
3500 |
90-135 |
|
4001 |
100-150 |
|
Size for maximum flow rates shown above, and adjust flow to the boiler to obtain 120°F outlet water temperature.