Raypak C-R206AE Installation Manual

INSTALLATION INSTRUCTIONS
Flow Switch & Temperature/ Pressure Gauge
For Atmospheric
Models C-R206AE-406AE
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids or other
combustible materials in the vicinity of this or any other appliance. To do so may result in an explosion or fire.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
NOTE: Not for use with millivolt units.
Models C-R207AE-407AE
For Low NOx
Catalog No. 6000.59.1B Effective: 03-08-12 Replaces: 03-28-07 P/N 241309 Rev. 3
NOTE: These instructions are intended primarily for
PLUMBING
CPVC TAILPIECE O-RING & RING NUT (SUPPLIED)
CPVC MANIFOLD (SUPPLIED)
T&P GAUGE (SUPPLIED)
GASKETS, FLANGES & BOLTS (WITH ORIGINAL EQUIPMENT)
FLOW SWITCH COVER (SUPPLIED)
MALE CPVC CONNECTOR (WITH ORIGINAL EQUIPMENT)
use by qualified personnel specifically trained and experienced in the installation of this type of heating equipment and related system components. Installation and service personnel must be licensed in some states. Persons not qualified shall not attempt to install this equipment nor attempt repairs according to these instructions.
Before Starting
1) Turn off power to the heater at the circuit breaker.
2) Turn off gas supply.
3) Shut off the water supply to the heater.
DANGER - SHOCK HAZARD: Make sure electri­cal power to the heater is disconnected to avoid potential serious injury or damage to components.
Kit Contents
Each kit includes:
(1) Temperature and Pressure gauge (1) Pre-wired Flow Switch with outdoor cover (2) Paddles (1) Screw, #6-32 x 3/16 (1) 2” CPVC Tailpiece Connector (1) 2” CPVC Manifold Adapter (1) O-Ring (2) Female spade terminals (1) Ring nut
This kit is primarily intended for jurisdictions requiring the addition of a flow switch and/or temperature and pressure gauge on pool heaters.
4) Allow heater to cool down before attempting work.
INSTALLATION
1. Remove main front panel door and set aside.
2. Remove the front control panel screws (2 each located at the ends of the panel). Lower front panel to expose the main circuit board.
3. Remove transformer cover located on either the upper right or left side.
4. Locate conduit opening above power conduit opening on the waterside of the heater.
5. Locate the Inlet/Outlet header.
6. Install 2” flanges to header ports, if not already installed.
Fig. 1: Flow Switch and Temperature and Pressure Gauge
2
Loading...
+ 2 hidden pages